Manuel d'utilisation / d'entretien du produit MAGNUM SG CONTROL MODULE IM398 du fabricant Lincoln Electric
Aller à la page of 22
MA GNUM SG CONTROL MODULE OPERA TOR’S MANUAL IM398 February, 2000 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part.
SAFETY FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
SAFETY ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ’ s recommendations.
SAFETY PR É CA UTIONS DE S Û RET É Pour votre propre protection lire et observer toutes les instructions et les pr é cautions de s û ret é specifiques qui parraissent dans ce manuel aussi bien que les pr é cautions de s û ret é g é n é rales suiv- antes: S û ret é Pour Soudage A L ’ Arc 1.
Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
T ABLE OF CONTENTS Page SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5 PRODUCT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Description The Magnum SG Control Module is an interface between the welding power source and the Magnum Spool Gun. The Control Module and Spool Gun combination provide a system for welding primarily with aluminum electrode wire using a con- stant voltage welding power source.
A CCESSORIES For Static (Transformer Type) Power Sources Power SP-150 SP-200 SP-250/SP 250-I SP-255/SP 255-I CV Output Machine Source & Wire-Matic 250 & Wire-Matic 255 with Contactor Spool Gun.
A CCESSORIES -10- For Rotating (Engine-Driven Type) Power Sources: Recommended 14-pin Terminal Input Amphenol Strip Internal 115V AC Cable Cold Machine* connector? (2,4,31,32) Contactor? Outlet? Assem.
INST ALLA TION Safety Precautions W ARNING ELECTRIC SHOCK can kill • Have an electrician install and service this equipment. • Turn the input power off at the fuse box before working on equipment. • Do not touch electrically hot parts. Read “Arc Welding Safety Precautions” in the Operating Manual before proceeding.
INST ALLA TION Connection to Power Source Connect the control module to the power source using either a K492-10, K493-10 or K691-10 Input Cable Assembly (ordered separately), and follow the simple steps below. Installation of K492-10 Input Cable to Power Sources with a Terminal Strip 1.
INST ALLA TION 2. Attach the control cable Amphenol, gas line con- nector, and electrode cable terminal to their respective connectors on the rear panel of the Control Module. 3. At the other end of the cable: Connect the gas line to the gas cylinder regulator 4.
INST ALLA TION -14- When connecting the Control Module to a non-Lincoln power source, determine which type of output contactor your power source has. If the switch is not in the correct position, remove the single screw securing the lockout bar and remove.
OPERA TION W ARNING ELECTRIC SHOCK can kill • Do not touch electrically live parts or electrode with skin or wet clothing. • Insulate yourself from work and ground. • Keep your head out of fumes. • Use ventilation or exhaust to remove fumes from breathing zone.
OPERA TION MAINTENANCE Setting Gas Flow Rate on Gas Cylinder Regulator Gas handling systems having adjustable flow valves should be set per the information in the spool gun operating manual. A typical value is 30 cubic feet per hour (cfh), or 14 liters per minute.
DIA GRAMS NOTE: This diagram is for reference only. It is not accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
NO TES.
Now A vailab le...12th Edition The Procedure Handbook of Ar c W elding With over 500,000 copies of previous editions published since 1933, the Procedure Handbook is considered by many to be the “ Bible ” of the arc welding industry. This printing will go fast so don ’ t delay.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIPAMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lincoln Electric MAGNUM SG CONTROL MODULE IM398 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lincoln Electric MAGNUM SG CONTROL MODULE IM398 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lincoln Electric MAGNUM SG CONTROL MODULE IM398, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lincoln Electric MAGNUM SG CONTROL MODULE IM398 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lincoln Electric MAGNUM SG CONTROL MODULE IM398, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lincoln Electric MAGNUM SG CONTROL MODULE IM398.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lincoln Electric MAGNUM SG CONTROL MODULE IM398. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lincoln Electric MAGNUM SG CONTROL MODULE IM398 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.