Manuel d'utilisation / d'entretien du produit INVERTEC V350-PRO IM679-A du fabricant Lincoln Electric
Aller à la page of 40
INVERTEC V350-PRO OPERA TOR’S MANUAL For use with machines Code 10651, 10669, 10852 IM679-A February, 2001 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation .
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ’ s recommendations.
iv SAFETY iv PRÉCA UTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les pr é cautions de s û ret é specifiques qui parraissent dans ce manuel aussi bien que les pr é cautions de s û ret é g é n é rales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi T ABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications .........................................................................
V350-PRO A-1 INST ALLA TION A-1 TECHNICAL SPECIFICA TIONS - INVERTEC V350-PR O INPUT A C V OL T A GE & DC OUTPUT Product Ordering Input AC Rated DC Output Output Weight Dimensions Name Information Voltage Amps/Volts/Duty Cycle Range with Cord HxWxD (continuous) K1728-1 Factory Factory 82.
A-2 INST ALLA TION A-2 SELECT SUIT ABLE LOCA TION The Invertec V350-PRO will operate in harsh environ- ments. Even so, it is important that simple preventa- tive measures are followed in order to assure long life and reliable operation.
A-3 INST ALLA TION A-3 V350-PRO LN-7 Connection Instructions An LN-7 can only be used with the “ Factory ” & “ Advance Process ” versions of the 350-Pro. • Turn the Invertec power switch "off". • Connect the K480 control cable from the LN-7 to the 115VAC 14-pin wire feeder MS-style connector on the rear of the Invertec.
A-4 INST ALLA TION A-4 V350-PRO QUICK DISCONNECT PLUGS A quick disconnect system is used for the welding cable connections. The welding plug included with the machine is designed to accept a welding cable size of 1/0 to 2/0. 1. Remote 25mm (1 in.) of welding cable insulation.
B-1 OPERA TION V350-PRO B-1 SAFETY PRECA UTIONS ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet clothing. • Insulate yourself from work and ground. • Always wear dry insulating gloves. ------------------------------------------------------------------------ FUMES AND GASES can be danger- ous.
B-2 OPERA TION B-2 For all versions, these trigger modes can be over-ridden (switched) with the WELD TERMINALS push button. When changed, the unit will power up in the configuration it was in when it was last powered down. 5. THERMAL • This status light indicates when the power source has been driven into thermal overload.
B-3 OPERA TION B-3 • The Arc Control regulates the relative Slope of the process. Slope dynamically controls the force the arc has to penetrate an open root.
B-4 OPERA TION B-4 7A. AD V ANCED PR OCESS P ANEL (See Figure 2) To program Welding modes. Select knob is used to Scroll through all Welding modes. The Memory button is used to store and access Welding modes into loca- tions M1 thru M8.
B-5 OPERA TION B-5 V350-PRO CONTROLS: (See Figure 2) The MEMORY button and SELECT knob are used together to select a welding process an store it in (M1 thru M8). The SELECT knob scrolls through the, welding process modes and memory modes M1 thru M8. The MEMORY button stores the welding process in memory.
B-6 OPERA TION B-6 WELD MODE DET AILS: V350-PRO Mode Range Comments Stick Soft 5 - 425 amps The stick soft mode is the best selection for general stick applications. Arc Control = Arc Force Hot Start = Initial hot start current (min = start a match set amps, Max.
B-7 OPERA TION B-7 PULSE PROGRAMS: V350-PRO .030 Steel 65 - 1200 .035 Steel 55 - 800 .045 Steel 50 - 700 .052 Steel 75 - 550 .045 Metal Core 50 - 650 .052 Metal Core 50 - 500 .030 Stainless Ar Blends 85 - 770 .030 Stainless He Ar CO2 110 - 770 .035 Stainless Ar Blends 65 - 770 .
B-8 OPERA TION B-8 V350-PRO LOWER CASE PANEL The output studs, line switch and remote connector are located on the lower case front. 9 . Both STUDS contain "Twist-Mate" connector inserts. • The Negative stud is configured to accept the pass through gas system.
B-9 OPERA TION B-9 V350-PRO DESIGN FEATURES and ADVANTAGES • Multiple process DC output range: 5 - 425 amps • Presettable welding outputs. • Built-in Line Voltage Compensation holds the output constant over +/- 10% input fluctuations.
C-1 A CCESSORIES C-1 OPTIONS / A CCESSORIES CONSTRUCTION VERSION – K1728-2 • All welding modes for this model run with local out- put control and weld terminals ON (e.
D-1 MAINTENANCE D-1 VISU AL INSPECTION Clean interior of machine with a low pressure air stream. Make a thorough inspection of all compo- nents. Look for signs of overheating, broken leads or other obvious problems. Many problems can be uncovered with a good visual inspection.
E-1 TR OUBLESHOO TING E-1 V350-PRO If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TR OUBLESHOO TING E-2 V350-PRO If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-3 TR OUBLESHOO TING E-3 V350-PRO Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-4 TR OUBLESHOO TING E-4 V350-PRO Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-5 TR OUBLESHOO TING E-5 V350-PRO Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
F-1 DIA GRAMS F-1 V350-PRO TURN THE POWER SWITCH OF THE WELDING POWER SOURCE "OFF" BEFORE INSTALLING PLUGS ON CABLES OR WHEN CONNECTING OR DISCONNECTING PLUGS TO WELDING POWER SOURCE.
F-2 DIA GRAMS F-2 V350-PRO N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION. N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF", REVERSE ELECTRODE AND WORK CABLE AT POWER SOURCE. N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
F-3 DIA GRAMS F-3 V350-PRO N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION. N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF", REVERSE ELECTRODE AND WORK CABLE AT POWER SOURCE. N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
F-4 DIA GRAMS F-4 V350-PRO N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION. N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF", REVERSE ELECTRODE AND WORK CABLE AT POWER SOURCE. N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
F-5 DIA GRAMS F-5 V350-PRO Only qualified persons should install, use or service this machine. using the disconnect switch at the fuse box WARNING Turn off input power to the Welding Power Source Before connecting the wire feeder. ELECTRIC SHOCK CAN KILL N.
F-6 DIA GRAMS F-6 V350-PRO Only qualified persons should install, use or service this machine. using the disconnect switch at the fuse box WARNING Turn off input power to the Welding Power Source Before connecting the wire feeder. ELECTRIC SHOCK CAN KILL N.
F-7 DIA GRAMS F-7 V350-PRO NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
F-8 DIA GRAMS F-8 V350-PRO 1 4.7 9 1 2.4 4 3.44 21.60 27.82 5.50 10.0 0 MOUNTING HOLE LOCATIONS M19527 13.1 0 1/4- 20 NUT (4 PLAC ES) NOTE: MOUNTING SCREWS CA 8/00 N NOT PROTR UDE MORE THAN 0.
NO TES V350-PRO.
NO TES V350-PRO.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lincoln Electric INVERTEC V350-PRO IM679-A c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lincoln Electric INVERTEC V350-PRO IM679-A - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lincoln Electric INVERTEC V350-PRO IM679-A, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lincoln Electric INVERTEC V350-PRO IM679-A va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lincoln Electric INVERTEC V350-PRO IM679-A, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lincoln Electric INVERTEC V350-PRO IM679-A.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lincoln Electric INVERTEC V350-PRO IM679-A. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lincoln Electric INVERTEC V350-PRO IM679-A ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.