Manuel d'utilisation / d'entretien du produit INVERTEC V205-T AC/DC TIG du fabricant Lincoln Electric
Aller à la page of 36
INVER TEC V205-T A C/DC TIG ® OPERA TOR’S MANUAL IM728 October, 2004 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ...
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv Mar. ‘93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi vi T ABLE OF CONTENTS Page Installation ................................................................................................................... ....Section A Technical Specifications .....................................................
A-1 INST ALLA TION V205-T AC/DC TIG A-1 Input Amps 34A 28A 20A 34A 25A 20A 30A 23A 19A 30A 18A 15A Type of Output AC/DC Output Amps Volts at Rated Amperes (Stick) 110 24.4V 90 23.6V 70 22.8V (TIG) 150 16V 120 14.8V 100 14V (Stick) 180 27.2V 150 26V 130 25.
A-2 INST ALLA TION V205-T AC/DC TIG A-2 MACHINE GROUNDING AND HIGH FRE- QUENCY INTERFERENCE PROTECTION The Capacitor Discharge Circuit used in the high fre- quency generator, may cause many radio, TV and electronic equipment interference problems. These problems may be the result of radiated interference.
A-3 INST ALLA TION V205-T AC/DC TIG A-3 3. Be sure the torch and work cable rubber cover- ings are free of cuts and cracks that allow high frequency leakage. Cables with high natural rub- ber content, such as Lincoln Stable-Arc ® better resist high frequency leakage than neoprene and other synthetic rubber insulated cables.
A-4 INST ALLA TION V205-T AC/DC TIG A-4 230V INPUT The equipment is provided with a 230/115V cable, 6.6ft.(2m) in length with a 230V 6-50P attachment plug. The Invertec V205-T AC/DC performs best when con- nected to 230VAC inputs. This input allows full output of the machine (200 amps).
A-5 INST ALLA TION V205-T AC/DC TIG A-5 This unit does not include a TIG torch, but one may be purchased separately. The accessories section of this manual lists a number of Lincoln Electric TIG torches, and TIG Torch Starter Packs that are recommended for use with this machine; however, any similar TIG torch can be used.
A-6 INST ALLA TION V205-T AC/DC TIG A-6 REMOTE CONTROL CONNECTION A remote control receptacle is provided on the lower center case front of the welder for connecting a remote control to the machine. Refer to the Optional Accessories section of this manual for available remote controls.
B-1 OPERA TION V205-T AC/DC TIG B-1 Read and understand this entire section before operating your machine. SAFETY INSTRUCTIONS ELECTRIC SHOCK can kill. • Do not touch electrically live parts such as output terminals, electrode or internal wiring. • Insulate yourself from the work and ground.
B-2 OPERA TION B-2 REAR CONTROL P ANEL (FIGURE B.1) • I1: Off/On switch turns on the electric power to the welder. It has two positions, "O" off, and "I" on.
B-3 OPERA TION B-3 V205-T AC/DC TIG 1 . Input Voltage warning light green LED - Indicates that the machine is on and input voltage is within acceptable range. 2. Thermal Shutdown Light (yellow LED) - Indicates thermal over load or output disabled for incorrect supply voltage.
B-4 OPERA TION B-4 5. Output / Parameter Adjust Knob - Allows you to continuously adjust the current both in TIG and in Stick welding. Allows you to change the value, shown on "Digital Display Item 6", of the parameter selected with "Setup/Parameter select button Item 4".
B-5 OPERA TION B-5 3. Press and hold the TIG torch trigger when the main part of the weld is complete. The machine will now decrease the output current at a controlled rate, or downslope time, until the Finish current is reached. Both the Downslope Time and the Finish Current are presettable.
B-6 OPERA TION B-6 SET UP MENU Many additional parameters can be modified via the Set Up Menu. To access the Set Up Menu: • Position the ON/OFF switch to OFF “ 0 ” .
B-7 OPERA TION B-7 WELDING POLARITY DC Electrode Negative Polarity (Direct Current Straight Polarity) (see FIGURE B.4) While Welding, there is a continuous flow of electrons from the electrode to the workpiece.
A.C.- PULSED TIG B-8 OPERA TION B-8 DC Electrode Positive Polarity. (Direct Current Reverse Polarity) (see Figure B.5) In this case, there is a continuous flow of electrons from the workpiece to the electrode. The reverse polarity is used for welding alloys covered with a layer of refractory oxide.
1. The AC wave balance can be set to a higher per- centage electrode negative which minimizes tung- sten heating and erosion. 2. The AC frequency can be varied to "focus" the arc. Increasing the AC frequency above 60Hz will nar- row the cone shape arc from the tungsten ’ s tip.
B-10 OPERA TION B-10 PROTECTIVE GAS Both argon and helium work when welding aluminum. Argon is preferred, due to its lower cost and consump- tion rate.
B-11 OPERA TION B-11 DC TIG WELDING QUICK ST ART UP ELECTRIC SHOCK can kill. • Have an electrician install and service this equipment. • Turn the input power off at the fuse box, dis- connect or unplug supply lines and allow machine to sit for five minutes minimum to allow the power capacitors to discharge before working inside this equipment.
C-1 ACCESSORIES C-1 OPTIONAL ACCESSORIES AND COMP A TIBLE EQUIPMENT Factory Installed Twist-Mate Cable Connectors 1 – standard for Ground Clamp 1 – Gas Pass through for Tig Torch Strap Packet Instruction Manual Field Installed K857 - Remote Output Control - For Stick welding.
D-1 MAINTENANCE D-1 V205-T AC/DC TIG SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Have an electrician install and ser- vice this equipment. • Turn the input power off at the fuse box, disconnect .
E-1 TROUBLESHOOTING E-1 V205-T AC/DC TIG This Troubleshooting Guide is provided to help you locate and repair possible machine malfunctions. Simply follow the three-step procedure listed below. Step 1. LOCATE PROBLEM (SYMPTOM). Look under the column labeled “ PROBLEM (SYMP- TOMS) ” .
E-2 TROUBLESHOOTING E-2 V205-T AC/DC TIG Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-3 TROUBLESHOOTING E-3 V205-T AC/DC TIG Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-4 TROUBLESHOOTING E-4 V205-T AC/DC TIG Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
F-1 WIRING DIAGRAMS F-1 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
NOTES V205-T AC/DC TIG.
NOTES V205-T AC/DC TIG.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lincoln Electric INVERTEC V205-T AC/DC TIG c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lincoln Electric INVERTEC V205-T AC/DC TIG - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lincoln Electric INVERTEC V205-T AC/DC TIG, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lincoln Electric INVERTEC V205-T AC/DC TIG va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lincoln Electric INVERTEC V205-T AC/DC TIG, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lincoln Electric INVERTEC V205-T AC/DC TIG.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lincoln Electric INVERTEC V205-T AC/DC TIG. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lincoln Electric INVERTEC V205-T AC/DC TIG ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.