IM524-D October , 2001 For use with machines having Code Numbers: 10365 10511 10366 10512 10433 10520 10434 10607 10449 10610 INVER TEC PO WER W A VE 450 TM OPERA TOR’S MANUAL Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind.
FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b . Operate engines in open, well-v entilated areas or vent the engine e xhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cov er plates to protect your e yes from sparks and the ra ys of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. T ur n off input power using the disconnect switch at the fuse bo x before working on the equipment. 8.b . Install equipment in accordance with the U .S. National Electrical Code, all local codes and the manuf acturer’ s recommendations.
iv SAFETY iv PRÉCA UTIONS DE SÛRETÉ P our votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté P our Soudage A L ’Arc 1.
Thank You f or selecting a QU ALITY product by Lincoln Electric. W e want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we hav e in br inging this product to you! Read this Operators Man ual completely bef ore attempting to use this equipment.
T ABLE OF CONTENTS vi vi PO WER W A VE 450 Page Safety .................................................................................................................................................i-iv Installation .................................
vii vii PO WER W A VE 450 W eld from Memory , Dual Procedur e Overlay .....................................................................B-11 Dual Wire Feeders, Dual Pr ocedure Overlay.................................................................
PO WER W A VE 450 TECHNICAL SPECIFICA TIONS - POWER WA VE 450 INPUT - THREE PHASE 50/60 HZ. ONL Y Input V olta g es: 200 230 400 460 575 Input Currents @ 500A/40 VDC 87 76 44 38 32 @ 450A/38 VDC 75 65.
Read this entire installation section before y ou start installation. SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Only qualified personnel should perform this installation. • T ur n the input power OFF at the disconnect switch or fuse box before working on this equipment.
Failure to follow these instructions can cause immedi- ate failure of components within the welder . GROUND CONNECTIONS The frame of the welder must be grounded. A ground terminal marked with the symbol is located inside the reconnect/input access door for this purpose.
INST ALLA TION A-4 A-4 PO WER W A VE 450 2 3 1 FIGURE A.3 – FRONTP ANEL/BACK P ANEL 4 (OUT) (IN) 6 5 1 WORK TERMINAL 2 ELECTRODE TERMINAL 3 REMOTE CONTROL AMPHENOL RECEPT ACLE 4 WA TER COOLING FITTI.
OPERA TION B-1 B-1 PO WER W A VE 450 OPERA TING INSTRUCTIONS Read and understand this entire section of operating instructions before operating the machine. SAFETY INSTRUCTIONS ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrodes with your skin or wet cloth- ing.
QUICK ST ART REFERENCE FOR USING THE PROCESS SELECTION OVERLA Y Read and understand the “Controls and Settings” and “Operating Overlays” sections of this manual before using the following Quick Start Reference pr ocedure to operate the Power W ave.
GENERAL DESCRIPTION The INVERTEC Power W ave power source is a high performance, digitally controlled inverter welding power source capable of complex, high-speed wave- form control. It uses thr ee-phase input power only . The Power W ave is designed to be used as a synergic welding system in conjunction with a wire feeder .
CONTROLS AND SETTINGS All operator controls and adjustments ar e located on the case front of the Power W ave. Refer to Figure B.1 and corresponding explanations. FIGURE B.1 – CASE FRONT CONTROLS CASE FRONT CONTR OLS Refer to Figure B.1 for the location of the following controls: 1.
OPERA TING OVERLA YS O VER VIEW The Power W ave is controlled by a panel of keys (key- pad) located on the front of the machine. The opera- tor can access controls by placing an overlay over the keys. An OVERLA Y is a special plastic sheet with a number of keys and symbols printed on one side and a bar code printed on the other .
O VERLA Y TYPES Four types of overlays can be used with the Power W ave. 1. Process Overlays. These overlays are used to create, save and r ecall specific welding proce- dures by selecting and adjusting the various weld- ing settings that have been programmed into the Power W ave at the factory .
1. LCD DISPLA Y WINDOW : Power up the machine with this overlay in place. When the Power W ave is turned on, the following message appears on the display for a few seconds: LINCOLN ELECTRIC VERSION X.
3. ELECTRODE CLASS UP/DOWN: Use the ELEC- TRODE CLASS UP or DOWN keys to select from the material types available for the selected process. Pr ess the ELECTRODE CLASS UP or DOWN key until the desired material type is dis- played.
10. RECALL FROM MEMOR Y KEY : This key is used to recall an existing pr ocedure fr om memory . Y ou can recall and use any of the pr eviously created welding procedur es that are stor ed in one of the eight memory locations. Simply press the RECALL FROM MEMOR Y key and then the appropriate MEMOR Y LOCA TION NUMBER key .
1. LCD DISPLA Y WINDOW: Power up the machine with this overlay in place. When the Power W ave is turned on, the following message appears in the display window for a few seconds: LINCOLN ELECTRIC V ersion X.X This display is followed by: OVERLA Y ID NUMBER = 2 This message is then replaced by the following message: SELECT A MEMOR Y LOCA TION 2.
1. LCD DISPLA Y WINDOW: Power up the machine with this overlay in place. When the Power W ave is turned on, the following message appears in the display window for a few seconds: LINCOLN ELECTRIC V ersion X.X This display is followed by: OVERLA Y ID NUMBER = 3 This message is then replaced by the following message: SELECT A MEMOR Y LOCA TION 2.
When a pair of welding procedur es are r ecalled from memory , the display window will show the procedur e description, wire feed speed, and the preset voltage or ar c length trim of the LAST pro- cedure welded with. With this overlay in place, the wire feed speed and the preset voltage or ar c length trim can be changed from the wir e feeder .
1. LCD DISPLA Y WINDOW: Power up the machine with this overlay in place. When the Power W ave is turned on, the following message appears in the display window for a few seconds: LINCOLN ELECTRIC VERSION X.X This display is followed by: OVERLA Y ID NUMBER = 9 2.
1. LCD DISPLA Y WINDOW: Power up the machine with this overlay in place. When the Power W ave is turned on, the following message appears in the display window for a few seconds: LINCOLN ELECTRIC V ersion X.X This display is followed by: OVERLA Y ID NUMBER = 4 This message is then replaced by the following message: SELECT A MEMOR Y LOCA TION 2.
Use the LIMIT UP and LIMIT DOWN keys to change the maximum wire feed speed to the desired value. Press the SET LIMIT key again. The new maximum and old minimum wire feed speeds will be dis- played. Use the LIMIT UP and LIMIT DOWN keys to change the minimum wire feed speed to the desired value.
1. LCD DISPLA Y WINDOW: Power up the machine with this overlay in place. When the Power W ave is turned on, the following message appears in the display window for a few seconds: LINCOLN ELECTRIC V ersion X.X This display is followed by: OVERLA Y ID NUMBER = 0 This message is then replaced by the following message: POWER WA VE SETUP 2.
When the “WA TER COOLER PRESSURE” light turns on, release the key . 5. WIRE FEEDER 1 +/- POLARITY KEY : Press this key to change the present voltage sensing polari- ty of wire feeder 1. The pr esent polarity of wire feeder 1 is indicated by the “WIRE FEEDER 1+ POLARITY” light.
Use the ELECTRODE SENSE LEAD KEY to select either the - output terminal or the electrode sense (67) lead for the positive voltage refer ence. The work sense (21) lead is used only in rare cir cum- stances. For most installations, use the WORK SENSE LEAD KEY to select the - output terminal for the negative voltage refer ence.
O VER VIEW OF WELDING PR OCEDURES FLUX CORED ARC WELDING (FCA W) AND GMA W PROCEDURES F or each wire feed speed, a corresponding v oltage is preprogrammed into the machine b y welding e xper ts. This preprogrammed v oltage is the best aver age volt- age f or the procedure at the given wire f eed speed.
OPERA TION B-20 B-20 PO WER W A VE 450 T rigger Position 1 GMAW GMAW STICK 1 Pulse GMA W Pulse FCAW FCAW WFS DISPLA Y : WFS DISPLA Y : Wire Feed Speed Wire Feed Speed WFS and WFS and Preset VOL T AGE .
PULSE WELDING Some people hav e trouble getting used to the behavior of the pulsing arc. The parameters progr ammed into the P ower Wa ve hav e been thoroughly tested for their ability to deliv er a sound weld with good appearance. There are, ho we ver , a f ew things to k eep in mind when pulse welding.
OPTIONS/ACCESSORIES • Syner gic 7 wire feeder (K632-1) standard speed,or (K632-2) high speed • MAGNUM 400 gun (K471-2) or 550 gun (K598) • Internal water cooler • Undercarriages (Single [K961-.
There are two w ater connections on the rear of the P ower Wa ve. See Figure C.1. Connect the water lines between these connectors and those on the wire f eed- er . The water is f ed through the f eeder into the gun. When a water cooler is used, the w ater cooler must be enabled b y using the Setup Overla y .
SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Only Qualified personnel should perform this maintenance. • T ur n the input power OFF at the disconnect switch or fuse box before working on this equipment.
5. Locate two sets of two r esistors on the left side of the machine and three sets of two r esistors on the right side of the machine. See Figure D.1.
6. Locate the #9 and #12 terminals, identified by the “Dischar ge” labels, on each of the four Switch Boards. See Figur e D.2. 7. Using insulated, needle nose-type jumper leads and insulated gloves, connect one jumper lead to one end of the resistor obtained in step 4.
PREVENTIVE MAINTENANCE Perform the following preventive maintenance pr oce- dures at least once every six months. It is good prac- tice to keep a preventive maintenance r ecor d; a r ecord tag attached to the machine works best. 1. Remove the hex head scr ews from the sides and top of the machine.
MAINTENANCE D-5 D-5 PO WER W A VE 450 RECOMMENDED T OOLS FOR INST AL- LA TION OR SER VICE OF COOLER: • absorbent towels • alcohol wipe • 3 mm allen wrench (G3503 only) • sock et wrench • 4 i.
MAINTENANCE D-6 D-6 G3503-[ ] COOLER PERIODIC MAINTENANCE 1. Preparation: • Alwa ys s witch off the P ower Wa ve machine po wer . • Alwa ys disconnect the P ower W av e machine from ser vice input power . • Do not remove the pump relief v alve ’ s 3/4 in.
MAINTENANCE D-7 D-7 PO WER W A VE 450 FIGURE D.4 – GENERAL COMPONENT LOCA TIONS 1 DISPLA Y BOARD (BACK OF P ANEL) 2 POWER SWITCH 3 MAIN TRANSFORMER 4 AUXILIAR Y TRANSFORMER 5 INPUT RECTIFIER 6 HEA T.
TROUBLESHOOTING E-1 E-1 PO WER W A VE 450 HOW TO USE TROUBLESHOOTING GUIDE This T roubleshooting Guide is designed to be used by the machine Owner/Oper ator . Unauthorized repairs per-f or med on this equipment may result in danger to the technician and machine oper ator and will inv alidate your f actor y warranty .
Major physical or electrical dam- age is evident when the sheet metal cover(s) are r emoved. Machine is dead – no output – no fans – no displays. Machine has no output – fans are running – display is on – a “click- ing” sound is heard coming fr om the machine.
Machine has no output – no f ans – no displa y . Main input fuses are open, indicating e xcessive input current dra w . Machine has no output – no dis- pla y – fans run. Machine has no output – no dis- pla y – fans run – circuit breaker (5-amp) repeatedly trips.
Machine has no output – fans run – display is on. Machine regularly overheats – yel- low light (LED) on the front panel glows, indicating a thermal over- load. The fans run and the display is on. 1. Make sure that the machine was powered up with a pr operly installed overlay .
The voltage and/or wire f eed speed will not adjust to user satis- f action. The voltage and/or wire f eed speed can be adjusted on the wire f eeder but the changes are not shown on the P ower W av e. The Dual Procedure ov erlay is installed. The user cannot change from procedure “ A ” to procedure “ B, ” or vice versa.
Machine does not respond to ke ys being pressed, or the machine has improper displa ys. Machine displa y reads “ Error Inv alid Overlay , ” or it displays an incorrect ov erlay ID number on pow er-up. Machine displa ys “ ERR OR: S.L. NO T INITIALIZED ” on pow er-up.
The Beeper (Piezoelectric Buzzer) cannot be heard – machine operating normally . The welding parameters that w ere sav ed in memor y are different when recalled. The water cooler does not turn on. The machine beeps without the ke ys being pressed. 1.
Machine loses output while weld- ing. F ans and display are function- ing properly . F or no apparent reason the weld characteristics hav e changed. Machine often “ noodle welds ” with a par ticular procedure. 1. Check f or proper input voltages (per machine nameplate).
Now A vailab le ...12th Edition The Procedure Handbook of Ar c W elding With ov er 500,000 copies of previous editions pub lished since 1933, the Procedure Handbook is considered by man y to be the “ Bible ” of the arc welding industry . This printing will go fast so don ’ t dela y .
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German P or tuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German P or tuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS PAR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Ser vice through Subsidiaries and Distr ibutors Worldwide • Cle veland, Ohio 44117-1199 U .S.A. TEL: 216.481.8100 F AX: 216.486.1751 WEB SITE: www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lincoln Electric INVERTEC POWER WAVE 450 IM524-D c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lincoln Electric INVERTEC POWER WAVE 450 IM524-D - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lincoln Electric INVERTEC POWER WAVE 450 IM524-D, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lincoln Electric INVERTEC POWER WAVE 450 IM524-D va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lincoln Electric INVERTEC POWER WAVE 450 IM524-D, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lincoln Electric INVERTEC POWER WAVE 450 IM524-D.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lincoln Electric INVERTEC POWER WAVE 450 IM524-D. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lincoln Electric INVERTEC POWER WAVE 450 IM524-D ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.