Manuel d'utilisation / d'entretien du produit IM833-C du fabricant Lincoln Electric
Aller à la page of 49
Ranger 250 OPERA TOR’S MANUAL IM833-C June, 2005 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part.
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv Mar. ‘93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi vi T ABLE OF CONTENTS Page Installation ................................................................................................................... ....Section A Technical Specifications .....................................................
vii vii T ABLE OF CONTENTS Maintenance ......................................................................................................Section D Safety Precautions .................................................................................
Make/Model Description Horsepower Operating Displacement cu. in.(cu. cm) Starting Capacities @ 3600 RPM SPEED Bore x Stroke in.(mm) System RANGER 250 1. Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to rated capacity.
A-2 INST ALLA TION RANGER 250 A-2 MACHINE SPECIFICA TIONS - Ranger 250 (K1725-6, K1725-7, K1725-8, K1725-9) RECEPTACLES AUXILIARY POWER CIRCUIT BREAKER OTHER CIRCUIT BREAKERS (2) 120VAC Duplex (5-20R).
A-3 INST ALLA TION RANGER 250 A-3 LIFTING The RANGER 250 weighs approximately 575 lbs. with a full tank of gasoline. A lift bail is mounted to the machine and should always be used when lifting the machine. ADDITIONAL SAFETY PRECAUTIONS • Lift only with equipment of adequate lifting capacity.
A-4 INST ALLA TION RANGER 250 A-4 4. Typical conditions of use, i.e., travel speed; rough- ness of surface on which the trailer will be operat- ed; environmental conditions. 5. Conformance with federal, state and local laws. (1) (1) Consult applicable federal, state and local laws regarding specific requirements for use on public highways.
A-5 INST ALLA TION RANGER 250 A-5 An incorrect spark arrester may lead to damage to the engine or adversely affect performance. ------------------------------------------------------------------------ HIGH FREQUENCY GENERA TORS FOR TIG APPLICA TIONS The K930-2 TIG Module is suitable for use with the Ranger 250.
A-6 INST ALLA TION RANGER 250 A-6 Table A.1 lists recommended cable sizes and lengths for rated current and duty cycle. Length refers to the distance from the welder to the work and back to the welder. Cable diameters are increased for long cable lengths to reduce voltage drops.
A-7 INST ALLA TION RANGER 250 A-7 240 Volt 60 Hz. 3-Wire Service POWER COMPANY METER 240 VOLT 120 VOLT 120 VOLT LOAD N NEUTRAL BUS GROUND PREMISES DISCONNECT AND SERVICE OVERCURRENT PROTECTION GND N NOTE: No. 6 COPPER CONDUCTOR CABLE SEE NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE SIZE RECOMMENDATIONS.
A-8 INST ALLA TION RANGER 250 A-8 CONNECTION OF LINCOLN ELEC- TRIC WIRE FEEDERS Connection of LN-7 or LN-8 to the Ranger 250 1. Shut the welder off. 2.
A-9 INST ALLA TION A-9 7 . Set the "IDLE" switch to the "AUTO" position. When not welding, the Ranger 250 engine will be at the low idle speed. If you are using an LN-25 with an internal contactor, the electrode is not energized until the gun trigger is closed.
B-1 OPERA TION RANGER 250 B-1 GENERAL DESCRIPTION The Ranger 250 is a gasoline engine powered DC multi-process welding power source and 120 / 240 volt AC power generator. The engine drives a genera- tor that supplies three phase power for the DC weld- ing circuit and single phase power for the AC auxiliary outlets.
B-2 OPERA TION B-2 WELDING CONTROLS: 1. OUTPUT CONTROL: The CONTROL dial provides continuous control of the welding current or welding voltage depending on the selected welding mode.
B-3 OPERA TION B-3 4. WELD OUTPUT TERMINALS WITH FLANGE NUT : Provides a connection point for the electrode and work cables. Output stud covers provided on code 11270 and above. 5. GROUND STUD: (graphic) Provides a connection point for connecting the machine case to earth ground for the safest grounding procedure.
B-4 OPERA TION B-4 Operating the starter motor for more than 5 seconds can damage the motor. If the engine fails to start, release the switch and wait 10 seconds before opera- tion the starter again. Do NOT push the START button while the engine is running because this can damage the ring gear and/or the starter motor.
B-5 OPERA TION B-5 TIG WELDING The TOUCH START TIG setting of the MODE switch is for DC TIG (Tungsten Inert Gas) welding. To initiate a weld, the CONTROL dial is first set to the desired current and the tungsten is touched to the work.
B-6 OPERA TION B-6 ARC GOUGING The Ranger 250 can be used for limited arc gouging. For optimal performance, set the MODE switch to CC- STICK and the ARC CONTROL to +10. Set the CONTROL knob to adjust output current to the desired level for the gouging electrode being used according to the ratings in the following table.
C-1 ACCESSORIES C-1 RECOMMENDED OPTIONAL EQUIPMENT K957-1 HEAVY DUTY, TWO WHEEL TRAILER FOR SMALL WELDERS - For road, off-road and in-plant and yard towing. (For highway use, consult applicable federal, state and local laws regarding requirements for brakes, lights, fenders, etc.
D-1 MAINTENANCE D-1 RANGER 250 KOHLER ENGINE (1) Service more frequently when used in dusty areas and/or at high ambient temperatures. SAFETY PRECAUTIONS • Have qualified personnel do all maintenance and troubleshooting work. • Turn the engine off before working inside the machine or servicing the engine.
D-2 MAINTENANCE D-2 ENGINE OIL CHANGE Drain the oil while the engine is warm to assure rapid and complete draining. • Remove the oil filler cap and dipstick. Remove the yellow cap from the oil drain valve and attach the flexible drain tube supplied with the machine.
D-3 MAINTENANCE D-3 AIR FIL TER P APER ELEMENT 1. Loosen the cover retaining knob and remove the cover. 2. Remove the pre-cleaner from the paper element. 3. Remove the element cover nut, element cover, and paper element. 4. Do not wash the paper element or use pressurized air, as this will damage the element.
D-4 MAINTENANCE D-4 FUEL FIL TER 1. Check the fuel filter for water accumulation or sedi- ment. 2. Replace the fuel filter if it is found with excessive water accumulation or sediment. ENGINE ADJUSTMENT Adjustments to the engine are to be made only by a Lincoln Service Center or an authorized Field Service Shop.
D-5 MAINTENANCE D-5 RANGER 250 WELDER / GENERA T OR MAINTENANCE STORAGE: Store the RANGER 250 in clean, dry pro- tected areas. CLEANING: Blow out the generator and controls peri- odically with low pressure air. Do this at least once a week in particularly dirty areas.
E-1 TROUBLESHOOTING E-1 RANGER 250 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TROUBLESHOOTING E-2 RANGER 250 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-3 TROUBLESHOOTING E-3 RANGER 250 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-4 TROUBLESHOOTING E-4 RANGER 250 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-5 TROUBLESHOOTING E-5 RANGER 250 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
F-1 DIAGRAMS F-1 RANGER 250 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
F-2 DIAGRAMS F-2 RANGER 250.
F-3 DIAGRAMS F-3 RANGER 250.
F-4 DIAGRAMS F-4 RANGER 250.
F-5 DIAGRAMS F-5 RANGER 250.
F-6 DIAGRAMS F-6 RANGER 250.
F-7 DIAGRAMS F-7 RANGER 250 or ser vice t his equi pm ent. On l y qualified personnel should install,use Keep away from m oving parts. Keep guards in place. MOVING PART S can injure WA R N I N G Do not touch electrically live pa rts. before servicing.
F-8 DIAGRAMS F-8 RANGER 250.
F-9 DIAGRAMS F-9 RANGER 250.
F-10 DIAGRAMS F-10 RANGER 250 2 9/03.
F-11 DIAGRAMS F-11 RANGER 250.
C CIRCU IT BRE AKER S 41.2 0 1046.5 17.5 0 444.5 19.5 0 495.3 TRUC K/U NDE RC ARR IAG E MOU NTING HOLE S 7.22 183.3 24.8 6 631.3 2.62 66.5 23.50 596.9 15.50 393.7 CE NTER OF GR AVITY 29.8 0 756.9 NOTE: CASE F RONT GRAPHI CS MAY NOT MATCH ALL CODES. 42.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIPAMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lincoln Electric IM833-C c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lincoln Electric IM833-C - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lincoln Electric IM833-C, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lincoln Electric IM833-C va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lincoln Electric IM833-C, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lincoln Electric IM833-C.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lincoln Electric IM833-C. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lincoln Electric IM833-C ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.