MA GNUM 300FM and 400FM Fast-M ate ™ Gun and Cable Assemblies OPERA T ORʼS MANUAL IM389-C March, 2008 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by proper installation .
i SAFETY i MAGNUM® F AST -MA TE™ FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii MAGNUM® F AST -MA TE™ ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87.
iii SAFETY iii MAGNUM® F AST -MA TE™ FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ʼs recommendations.
iv SAFETY iv MAGNUM® F AST -MA TE™ PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L ʼArc 1.
MAGNUM® F AST -MA TE™ v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
Page General DescriptIon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section A Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GENERAL DESCRIPTION Description Gun Contact Tips Gas Product Cable Wire Size Standard Diffuser Gas Cable Gun T ube Number Length (m) in. (mm) Duty Assembly Nozzle Insulator Liner 60° 10 ft. .035 (0.9) KP14-35 K478-1 (3.0) .045 (1.2) -45 KP54A KP24A-62 KP34A KP44-3545-15 KP1928-2 15 ft.
GENERAL DESCRIPTION MAGNUM® F AST -MA TE™ Description Gun Contact Tips Gas Product Cable Wire Size Standard Diffuser Gas Cable Gun T ube Number Length (m) in. (mm) Duty Assembly Nozzle Insulator Liner 60° 10 ft. .035 (0.9) KP14-35 K479-1 (3.0) .045 (1.
INST ALLA TION INST ALLA TION ELECTRICAL SHOCK can kill. • Have an electrician install and ser- vice this equipment. • T urn the input power off at the fuse box before working on equipment.
OPERA TION OPERA TION ELECTRODES AND EQUIPMENT The Magnum® 300 FM and Magnum® 400 FM guns and cables have been designed for use with Lincoln L- 50 and L-56, solid steel wire electrodes for the GMA W process and Lincoln Outershield ® cored electrodes for the gas-shielded FCA W process.
MAGNUM® F AST -MA TE™ REMOV AL, INST ALLA TION AND TRIMMING INSTRUCTIONS FOR MAGNUM® LINERS FEEDING STEEL WIRE (KP1933, KP1936 and KP1955 series liners) NOTE: The variation in cable lengths prevents the interchangeability of liners.
MAGNUM® F AST -MA TE™ This screw should only be gently tightened. Overtightening will split or collapse the liner and cause poor wire feeding. ------------------------------------------------------------------------ 6. Replace the nozzle insulator and gas nozzle.
MAINTENANCE CABLE REP AIR The Magnum® 300 FM and Magnum® 400 FM guns feature the use of repairable cable connectors. If the cable ever gets severely damaged, it may be cut short- er and repaired by the user .
FIGURE E.4 MAINTENANCE MAGNUM® F AST -MA TE™ CABLE CONTROL LEAD INNER TUBE COPPER STRANDING CONTROL LEAD 1.65 (41.9 mm) SKIN * USE .38" (9.5 mm) SKIN FOR - FEEDER END OF FM MODELS .25" (6.4 mm) SKIN *- (BOTH CONTROL LEADS) FIGURE E.2 FIGURE E.
4.10 (104 mm) Terminal Lead Assembly Cable Handle Central Adapter Assembly Collar Nut Incoming Connector Assembly Connector Nut Cable Boot Strain Relief Strain Relief Housing Boot Nut - FIGURE E.5 MAINTENANCE e) Remove the incoming connector from the cable by unscrewing the connector nut from the incoming connector .
MAINTENANCE MAGNUM® F AST -MA TE™ THREAD SIZES FOR MAGNUM® 300 & 400 CONSUMABLES D-6 D-6.
TROUBLESHOOTING MAGNUM® F AST -MA TE™ If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING MAGNUM® F AST -MA TE™ Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING MAGNUM® F AST -MA TE™ Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
NOTES MAGNUM® F AST -MA TE™.
MAGNUM® F AST -MA TE™ NOTES.
W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS P AR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 441 17-1 199 U.S.A. TEL: 216.481.8100 F AX: 216.486.1751 WEB SITE: www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lincoln Electric 400FM c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lincoln Electric 400FM - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lincoln Electric 400FM, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lincoln Electric 400FM va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lincoln Electric 400FM, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lincoln Electric 400FM.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lincoln Electric 400FM. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lincoln Electric 400FM ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.