Manuel d'utilisation / d'entretien du produit SOLANA-BK du fabricant Lennox Hearth
Aller à la page of 26
SOLANA-BK SOLANA-BN SA VE THESE INSTRUCTIONS FOR FUTURE REFERENCE This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation.
2 W ARNING NEVER use gasoline, gasoline- type lantern fuel, kerosene, charcoal lighter fluid, naphtha, engine oil or similar liquids to start or “freshen up” a fire in this fireplace. Keep any flammable liquids a safe distance from the fireplace at all times.
3 T AB LE O F C O NT E NT S Safety Rules .......................................Page 2 Introduction .......................................Page 3 Parts Required ..................................Page 3 Optional Equipment ............................Page 3 EP A Qualified .
4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Building A Fire (starting and maintaining a fire) T o start a fire, place several crumpled up balls of newspaper in the firebox. Place small dry pieces of kindli ng on top of the paper , criss-c rossing the kindling so that there are air spaces in between.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 5 Figure 1 - Outside air Register D. Wet wood Wet or tarred wood will smoulder and smoke instead of burning properly . Y our dealer can help you determine if you have properly seasoned wood for burning.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 6 Caution: It is necessar y to remove the baffle from the top of the firebox before cleaning the chimney . Dealing With a Chimney Fire Regular chimney maintenance and inspection can preve nt chim ney fires.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 7 REFRACTORY REPLACEMENT The intense heat of the fire will normally cause hairline cracks in the refractory . These cracks can be minimized by proper curing as described in “First Fires”. They will not normally dimin- ish the effectiveness of the refractory .
8 Marginal Location Wind Direction Location Not Recommended Outside Air Intake Facing the Wind Location Not Recommended Location Recommended Figure 6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. FIREPLACE INST ALLA TION Locating The Solana Fireplace A.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 9 W ARNING When using a gas burner , it is mandatory to keep the chimney outside air register opened.
Non-Combustible Material NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 10 Mantel A wood mantel, if installed, must be at least 48" (1.2 m) above the base of the fireplace ( see Figure 8B ) . There is no restriction regarding the length or the width of the mantel.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 11 42” (1067 mm) 43” (1092 mm) 43” (1092 mm) 27-1/2” (699 mm) 10-5/8” (270 mm) 33” (838mm) 42-1/2” (1080 mm) 17-1/8” (435 mm) 28-5.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 12 Fireplace Side Insulated Chase Construction Fireplace Facing The fireplace should be framed using 2" x 3" (50mm x 75mm) or heavier lumber . Figure 9 on Page 11 shows the general framing layout.
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 12 - External Air Intake (Detail A) (Detail C) Outside Air Assembly (Fireplace and AC Chimney) The outside air assembly is mandator y for the fireplace and the AC chimney . During operation, the fireplace requires air for combustion and draws air out of the house.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 14 INST ALLA TION OF THE BLOWER KIT MODEL UZY5 NOTE: This blower kit can easily be installed when the fireplace has a pre-installed junction box. Y ou just have to plug them in. Rating: 120 Volts, 60Hz, .
15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. CHIMNEY SYSTEM GENERAL INFORMA TION The Sol ana™ firep lace is listed only with Security Chimneys™ Interna- tional Ltd. chimney systems, models ASHT+ 8", S-2100+ 8", or AC 8".
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 16 CHIMN EY INST ALLA TION INSTR UCTIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 19 ) . Use a plumb-bob to line up the center of the holes.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 17 Roof Down Slope Hole Size SLOPE ASHT+ S-2100+ AC Roof Pitch 8" 8" 8" 0 * 14-3/8" (365mm) 16" (406mm) 15" (380mm) .
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 18 Figure 24 Ch im ney 8” Elbow Offset & Height One Length Between Elbows T wo Lengths Between Elbows 8” 12” 18” 24” 36” 48" .
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 19 ANGLED WALL RADIA TION SHIELD (RSM+, RSMI30, RSMI45) When traversing a combustible wall with the chimney at a 30° or 45° angle, an angled firestop and/or wall radiation shield must be installed.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 20 Figure 29 - S-2100 Chimney Adaptor Chimney Adaptor - Canada only CHIMNEY ADAPTOR (S-2100+ / HT6000+) CANADA ONL Y The fireplace is normally supplied with a chimney adaptor suitable for the ASHT / HT6103+ chimney .
21 Fireplace Model Solana™ - Approved Venting Components 8" Diameter Chimney - Model ASHT+, S-2100+, HT6000+, HT6103+ or AC manufactured by Security Chimneys International only . Notes: 1. (Projet NovaT emp™) HT6000+ is equivalent to S-2100+ 2.
22 Se cu re T em p™ A SH T+ H ig h T em p. I ns ul a te d St ai nl es s St ee l Ch im ne y 8" D iam ete r , Lis ted t o C AN / UC L-S 60 4 a nd UL -1 03H T a t 120 0° F Description Cat./ Part No. Lengths and Misc. Chimney Components 8" Length, 8" Dia.
23 CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation; Side wall: 18” (457 mm) Ceiling: 7 feet (2135 mm) measured from the base of the fireplac.
24 Item # Description Cat. No. 1 Refractory Baffle PR-SR2028 2 Back Refractory PR-SR2027 3 Right Side Refractory PR-SR2025D 4 Left Side Refractory PR-SR2025G 5 Bottom Refractory PR-SR1722 6 Front Ref.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 25 REPLACEMENT P ARTS - SOLANA™ P A I N T 18 1 2 3 4 6 7 9 8 10 10 12 11 13 15 16 14 17 19 20 21 22 5.
26 Y our Fireplace's Model Number ________________________________________ Y our Fireplace's Serial Number ________________________________________ The Date On Which Y our Fireplace Was Inst.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lennox Hearth SOLANA-BK c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lennox Hearth SOLANA-BK - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lennox Hearth SOLANA-BK, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lennox Hearth SOLANA-BK va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lennox Hearth SOLANA-BK, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lennox Hearth SOLANA-BK.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lennox Hearth SOLANA-BK. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lennox Hearth SOLANA-BK ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.