User Manual C T ype Power Filter Model C3 and C3BLK.
Entire content s copyright © 2 010 American Power Conversion Corporation. All right s reserved. Reproduction in whole or in p art without permission is prohi bited. APC, the APC logo, and TRADE MARK NAMES are trademarks of Amer ican Power Conversion Corporatio n.
v T able of Content s Safety Information i Protect Y our Investment iii Class B Labeling and Instru ction Manual Requ irement s vi Introduction 1 Proven Expertise…Proven Reliability 1 Safety Precaut.
vi.
iii Registration V erifi cation Confir mation By registering your purchase now, it guarantees you will receive all the informati on and special offers you qualify for as the owner of this product. By registering your purchase now , you have a way to confirm yourself as the owner of the product in the event of fire, thef t or loss.
iv Class B Labeling and Instruction Manual Re quirements Devices subject to Certification must be labeled with an FCC Identifier . Devices subject to V erification or Ce rtification must be labeled with the following compliance statem ent: This device complies with Part 15 of the FCC Rules.
- 1 - Introduction Congratulations on purcha sing APC’ s C3 Power Filte r , shown in Figure 1. The power filter come s in two models. The C3 is silver and the C3BLK is black. However , the C3 and C3BLK ha ve the same performance, features and functionality .
- 2 - Safety Precautions Please ens ure that you have read and understand all of the safety information located in the front of th is manual. If you ha ve any questio ns about the safety information, .
- 3 - Features The following paragraphs describe the Model C3 Power Filter’ s major features. Surge Protection The C3 Power Filter provides a high leve l of surge protection for the voltage going into the unit, and thus protect s the devices connected to the unit.
- 4 - T op Panel The following section descr ibes the controls and indi cators on the top panel. T op Panel Controls and Indicators The top panel controls and indicators for the C3 Po wer Filter are detailed in Figure 2. Each numbered callout re fers to a corresponding numbered description found immediately below the picture.
- 5 - Outlet Panel and Side Panel This section describes outlet pa nel and side panel functionality . Outlet Panel Contro ls and Indicators The outlet panel for the C3 Power F ilter is shown in Figure 3. Each of the numbered callouts refers to the co rresponding numbered description found below , and on the following pages.
- 6 - Side Panel Contr ols and Indicato rs The side panel conn ectors for the C3 Power Filte r are detailed in Figure 4. Each numbered callout refers to a correspon ding numbered description found in the following pages.
- 7 - Surge Pr otected T elephone Jacks The C3 provides a teleph one circui t with surge protection to protect components connected via teleph one line. Connect the supplied RJ1 1 telephone cable fro m the wall jack (source) to the telephone line connect or marked IN .
- 8 - Inst allation C3/C3BLK installation consists of the following steps: 1. Make connections 2. Apply power Make Connections Prior to connecting equipment to the C3 Power Filter , ensure the unit is functioning by connecting th e AC Power Cord (provided) on the side p anel, shown as , in Figure 4.
- 9 - T echnical Specifications The following table contains the speci fications for the C3 and C3BLK Power Filters. Item Specification INPUT Input V oltage Range for Operation (on utility) 92V to 140.
- 10 - T roubleshooting This section describes possible cause s and solutions for the following problems: • Unit will not turn on . • WIRING OK indicator LED is not il luminated. Unit will not turn on Probable Cause: Input power cord is not connected properly .
- 11 - WIRING OK indicator LE D is not illuminated APC T echnical Support If a problem cannot be resolved contact APC T echnical Support. T elephone: 1-888-88APCA V , or visit: www .apcav .com Probable Cause: There are three reasons why this LED would not be illuminated: 1.
- 12 -.
.
08/2006 990-2929.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté APC Model C3 and C3BLK c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du APC Model C3 and C3BLK - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation APC Model C3 and C3BLK, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le APC Model C3 and C3BLK va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le APC Model C3 and C3BLK, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du APC Model C3 and C3BLK.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le APC Model C3 and C3BLK. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei APC Model C3 and C3BLK ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.