Manuel d'utilisation / d'entretien du produit MGE SNMP du fabricant APC
Aller à la page of 81
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 1/81 NMC Transverse - 66074 Environment Sensor - 66846.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 2/81 Table of Contents 1 MGE NET WORK SOLUT ION __________________ __________________ _________________ _______ 5 1.1 I NTRODU CTION __________________ __________________ __________________ _______________ 5 1.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 3/81 3.3.3 UPS Event log _________________ __________________ __________________ ___________ 30 3.3.4 STS Event log _____________________________ _________________ __________________ 30 3.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 4/81 8.1.1 UPS Alarm table _____________ __________________ _________________ ______________ 73 8.1.2 STS Alarm table _____________________ __________________ __________________ ______ 73 8.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 5/81 1 MGE Network Solu tion 1.1 Introduction ◗ provides infor mation on events concerning the suppl .
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 6/81 ◗ periodicall y accesses the in formation concer ning the U PS / STS, ◗ mak es this informatio.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 7/81 1.1.4 Connection 1.1.4.1 How to connect UPS / network : ◗ Insert the optio nal card in t he UPS / STS a nd connect the device to th e com puter network.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 8/81 ◗ NMC Transverse for UPS, in UPS slot, l ike the MGE Galaxy PW , MGE Galax y PW 1000, MGE Galax .
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 9/81 1.7 Technical data 1.7.1 Configuration The user c an configure the card with on e of the f ollowing m eans: ◗ W eb browser ◗ Local serial link ◗ Telnet conso le ◗ BOOTP/DHCP ◗ Mupgrade 1.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 10/81 ◗ Possib ility of notif ication of s tatus changes b y e-mail, SM S or SNMP tra ps ◗ Position.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 11/81 2 Installation and Co nfiguration For the follow ing sections, r ead the installati on manual supplied with the card or available f or download on the www.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 12/81 3 Supervision / Administratio n via a Web brow ser A JVM (Jav a Virtual M achine) is required to ensur e correct displa y of infor mation in HTM L pag es .
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 13/81 3.2 UPS / STS 3.2.1 “UPS properties” page ◗ This page gi ves instant acc ess to the ess ential inform ation about your UPS. This page is aut omaticall y refreshed ever y 10 seconds (b y default).
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 14/81 • • Battery operatio n • • Load powered by main AC • • Loss of comm unication with th.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 15/81 3.2.2 “STS properties” page ◗ This page gi ves instant acc ess to the ess ential inform ation about your STS. This page is aut omaticall y refreshed ever y 10 seconds (b y default).
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 16/81 “Commun ication” : indicat es the status of the comm unication bet ween the card a nd the STS.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 17/81 3.2.4 On-line help On-line contex tual help in E nglish is avai lable at the to p of each p age b y clicking on the Help link, which is always locate d on the top ri ght corner.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 18/81.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 19/81 3.2.5 UPS 3-Phase display Click 3-ph ase display to a ccess to the deta iled m onitoring page This item is added to the m enu for all si ngle UPSs having a three-p hase output.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 20/81 3.2.5.2 Battery measuremen ts 3.2.5.3 By Pass measuremen ts By Pass current By Pass voltag e Phas.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 21/81 3.2.6 STS 3-Phase display Click 3-ph ase display to a ccess to the deta iled m onitoring page This item is added to the m enu for all si ngle UPSs having a three-p hase output.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 22/81 3.2.6.1 Source 2 input measu rement 3.2.6.2 Source 2 input measu rement 3.2.7 UPS Control Click on the “U PS Control ” section in the m enu. If the UPS is not com patibl e with this func tion, a warn ing m essage is sent to th e user.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 23/81 ◗ The shutdow n sequences t ake into accou nt the tim e required for the reg istered ser vers to shut do wn without losing d ata ( see sh utdown param eters ) .
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 24/81 3.2.8 UPS weekly schedule programm ing Click on the “ Weekly sche dule” sec tion of the m enu. If the UPS is not com patibl e with this func tion, a warn ing m essage is sent to th e user.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 25/81 3.2.9 Shutdown parameters ◗ Click on the “ Shutd own p arameters ” section in t he menu to s ee the list of parameters.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 26/81 3.2.10 Viewing the alarms ◗ Click on the “ Alarm table” section in the m enu to vie w the list of current alarm s. The table of managed alarms is included in the ap pendix .
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 27/81 3.3 Logs 3.3.1 UPS Measurements Click on the “ Measuremen ts” sec tion in the menu .
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 28/81 3.3.2 STS Measurements Click on the “ Measuremen ts” sec tion in the menu .
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 29/81 Select the tim e range to v iew.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 30/81 3.3.3 UPS Event log Click in the “Ev ent log” s ection of the m enu . ◗ “Save Log” enables all val ues saved to be opened or saved in CSV f orm at (compatible with Exc el t ype spreadsheets) .
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 31/81 ◗ “Save Log” enables all val ues saved to be opened or saved in CSV f orm at (compatible with Exc el t ype spreadsheets) . ◗ “Clear Log” e nables deleti on of all records.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 32/81 See the table of events gen erated in the STS event ta ble .
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 33/81 Select the tim e range to v iew: See the table of events gen erated in the System Alarm Table .
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 34/81 3.4 Notification 3.4.1 UPS Email Notification The card of fers the possibi lity of redirectin g UPS alarm s to an e-m ail server. The f orm at of these e-mails is compatible with mobile tel ephone tra nsfer s ystems using text m essages (SM S).
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 35/81 Environment ala rms mus t be selected to activate e-m ail notification of events c oncerning the Env ironment Sensor. The deta il of notif ied events is accessed via the Configur e Environm ent link .
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 36/81 3.4.2 STS Email Notification The card of fers the possibi lity of redirectin g STS alarm s to an e-m ail server. T he form at of these e-m ails is compatible with mobile tel ephone tra nsfer s ystems using text m essages (SM S).
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 37/81 3.4.3 Email Message Settings This page ena bles custom isation of the co ntent of the m essages rec eived by reci pients of e-m ails sent b y the card.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 38/81 - Message text is a free zon e. The body of the e-m ail sent is com posed of: - Message te xt , which is fr ee text. - the date and tim e of the e vent, as saved in the log.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 39/81 3.4.4 Email Example.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 40/81 3.5 Configuration The param eters of this m enu can onl y be modified afte r entering the “Us er Nam e” and “Password” .
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 41/81 3.5.1 Network Settings Click on the “ N etwork ” sect ion in the m enu. This m enu enables the ad ministrator to conf igure the network param eters of the card and author isation of th e rem ote upgrade of the em bedded system .
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 42/81 ◗ Dom ain name is the d om ain to which the car d belongs . This is the part of the full qua lified dom ain name that follows the h ost nam e and is used b y the DNS.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 43/81 3.5.2 System Click the “Syst em” section in the m enu. This m enu enables the cust omisation of the inform ation on the UPS pro perties / ST S properties a nd Environm ent pages.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 44/81 Choice of one of the avai lable languages: English , Fr ench, Italian, G erman, Sp anish cha nges the language of th e html interf ace pages ◗ Not e : Alarm notificat ion remains in En glish / Frenc h (reboot the bro wser af ter modif ication).
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 45/81 3.5.3 UPS Notified Applications Click the “Not ified Applica tion” s ection in the m enu. Security: the adm inistrator has to enter his login/password to view this inform ation.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 46/81 ◗ Shutdow n after : is the tim e available to t he user f rom the Power f ailure until the l aunch of the shut off sequence of the UPS. This param eter is optionna l.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 47/81 ◗ T rap community in dicates the nam e of the SN MP comm unity For m ore details, read the MIB description doc ument: available on th e www.apc.c om site.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 48/81 This page is us ed to define either the shut down or the notification s ettings used b y the Net work Shutdown Modules that co nnect to Ne twork Management Car d.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 49/81 Select an entr y in the list to m odify the values in the e dit zone at the bottom of the page. Not e that the N etwork Shutdown Modu le must no t be manuall y modified.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 50/81 ◗ T rap community in dicates the nam e of the SN MP comm unity For m ore details, read the MIB description doc ument: available on th e www.apc.c om site.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 51/81 ◗ Enter New Manager Login: Text field lim ited to 10 cha racters. Enabl es secure ac cess and m odification of pages. Default value “MG EUPS”.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 52/81 ◗ Change Commun ity Read -only: Text f ield limited to 3 1 characters. T his field is o nly validated af ter clicking on “ Save” . Defau lt value “pub lic”.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 53/81 3.5.7 Time Click the “Time” section in the menu. This m enu enables initialisatio n of the date a nd tim e of the card in thre e diff erent ways.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 54/81 list. Connection is m ade with the server and the date a nd tim e are set after click ing on the “Sav e” button.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 55/81 ◗ Nam e and status of each contact ca n be configure d ◗ Recor ding of events and measur emen.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 56/81 The last status cha nge of e ach contact is time-s tamped. The Internet bro wser updat es this page regularl y according to the Environment r efresh rate parameter on t he System settin gs page.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 57/81 3.6.3 UPS Environment Settings 3.6.3.1 UPS Environment Set tings The environm ent sensor m easures tem perature, hum idity and gives th e status of the 2 contacts ( used for door, alarms or generator unit).
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 58/81 The high alarm cannot be r eactivated w hile tem perature rem ains above the High threshold – Hyst eresis value. The low alarm cannot be re activated while temperature rem ains below Low th reshold + hyst eresis value.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 59/81 Same f eature than for UP S, without the system shutdown onl y available for U PS.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 60/81 4 Servers protection, U PS only 4.1 Set-up of the shutdown parameters The Network Shutdown Mo dul.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 61/81 4.1.1.3 Shutdown when backup time is less than W hen the Network Manage m ent Card detects that the percentage of back up time rem aining is less than the value set, the s hutdown se quence is starte d.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 62/81 4.2 The different server and UPS shutdown seque nces 4.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 63/81 4.2.2 Extended power outage, shutdown initia ted by the “Low battery power” message W hen the ”Low battery power ” mess age is displayed, the U PS is shut of f af ter taking into account the shutdo wn duration of the s ervers.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 64/81 4.2.3 Extended power outage, shutdown initia ted by the Shutdow n Timer, but utility restoration .
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 65/81 5 Configuring a set of cards with Mupgrade This f eature is particularl y useful to config ure large UP Ss / STSs inst alled base.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 66/81 4. Reset Configu ration To Def ault 5. Reset Agent 0. Exit Please Enter You r Choice => 6.1.1 Choice 1: SNMP agent configuration menu The blue lines are those d isplayed on sc reen.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 67/81 Text field lim ited to 10 char acters. Enabl es secure acc ess to the sections of the Configuratio n menu. Def ault value “MGEU PS”. a. Manager Pa ssword : * Text field lim ited to 10 char acters .
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 68/81 [2] 0.0.0.0 pub lic Not Access [3] 0.0.0.0 pub lic Not Access [4] 0.0.0.0 pub lic Not Access COMM ANDS - 1. Mod ify - Modif y an entry of table 2. Reset - Reset an entr y to default from t able 0.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 69/81 6.2 Configuration via Telnet You can access the configu ration m enu (see “ configura tion in local m ode ” section) from a s tation equipped wit h the Telnet prot ocol.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 70/81 Execute PuT TY and select the following options:.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 71/81 and Clic on « O pen » to sta rt connection.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 72/81 7 Maintenance 7.1 Software upgrade 7.1.1 Card firmware upgrade using Mupgrade (Windows) This f eature is particularl y useful to upgrad e a large U PS installe d base in on e operation.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 73/81 8 Appendices 8.1 Tables of alarms and events 8.1.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 74/81 Sources out of synchroniza tion Déphasage so urces 1 / 2 Emergenc y stop actived Défaut arrêt .
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 75/81 UPS return to n orm al temperature Fin de défaut tem pérature %s on sequence s tarted Début s.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 76/81 <Sensor nam e>: Hum idity is in norm al range <Sensor nam e>: L'hum idité est r.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 77/81 normal range un niveau norm al <Sensor nam e>: Hum idity is below lo w threshold %d % <S.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 78/81 8.1.5 System alarm table English French Cold boot Démar rage de la carte W arm boot Réinitialis.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 79/81 8.2 Glossary Bootp: Protocol based o n UDP us ed to allocate a n IP address corresponding t o an Ether net card during th e startup phase.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 80/81 N ETW ORK M ANAGEMENT C ARD Comm unication cards to su pervise U PS and comm unicate with Network.
Network Management Card User Manual Network Mana gement Card – User Manua l 34003676EN/HA Page 81/81 Trap (SNM P) This term describes an event th at affec ts an MIB variable. T raps are s ent to the manag er, which is programmed to perform specific task s upon reception of the traps.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté APC MGE SNMP c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du APC MGE SNMP - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation APC MGE SNMP, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le APC MGE SNMP va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le APC MGE SNMP, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du APC MGE SNMP.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le APC MGE SNMP. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei APC MGE SNMP ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.