Manuel d'utilisation / d'entretien du produit WS-7136U du fabricant La Crosse Technology
Aller à la page of 32
WS-7136U Wireless 433 MHz Temperature Station Instruction Manual.
2 TABLE OF CONTENTS Topic Page Inventory of Contents 3 Additional Equipment 4 Quick Setup 5-9 Detailed Setup Guide Battery Installation 10-12 Setting the Time For mat 13 Setting the Temp.
3 INVENTORY OF CONTENTS 1. The indoor temperature station (Figure 1) 2. The remote temperature sensor (TX6U) and mounting bracket. (Figure 2) 3. Mounting hardware.
4 ADDITIONAL EQUIPMENT (not included) 1. 1 Philips screwdriver. 2. 2 Fresh AAA 1.5V batteries. (for the indoor temperature station) 3. 2 Fresh AA 1.5V batteries.
5 QUICK SETUP Hint: Use good quality Alkaline Batteries and avoid rechargeable batteries. 1. Have the indoor temperature station and remote temperature sensor 3 to 5 feet apart. 2. Batteries should be out of all units for 10 minutes. 3. Place the batteries into the remote temperature sensor first, then into the indoor temperature station .
6 In this time the indoor temperature station and remote temperature sensor will start to talk to each other and the display will show both the indoor temperature and an outdoor temperature.
7 Notes on Outdoor Sensor Placement The remote temperature sensor should be placed in a dry, shaded area. Fog and mist will not harm your remote temp/humidity sensor but direct rain must be avoided. The remote temperature sensor has a range of 80 feet.
8 To complete the set up of your indoor temperature station after the 15 minutes have passed, please follow the steps below. 1. Press and hold the “SET” button for 5 seconds. Note: A “12h” or “24h” will appear on the top line. (“12h” for AM/PM, “24h” for military time) a.
9 and release the “SET” button once. 3. An hour will now be flashing. a. Press and release the “RESET/+” button until the correct hour is shown. Note: When in the 12h mode “PM” is displayed in the upper left corner of the display between noon and midnight.
10 Battery compartment DETAILED SETUP GUIDE I. BATTERY INSTALLATION A. REMOTE TEMPERATURE SENSOR 1. Remove the mounting bracket. 2. Remove battery cover. 3. Observing the correct polarity, install 2 AA batteries—make sure they do not spring free, or start-up problems may occur.
11 B. INDOOR TEMPERATURE STATION Note: After the batteries are installed, DO NOT press any buttons for 15 minutes. This may interfere with the signals, causing temperatures to register incorrectly. 1. Remove the battery cover on the backside. To do this, push up and pull out.
12 indoor temperature in the INDOOR LCD and outdoor temperature in the OUTDOOR LCD. II. PROGRAMMING SEQUENCE The programming sequence and default (factory) settings for the indoor temperature station is as follows: 1. Time Format (default 12h) 2. Temperature Format (default ° F) 3.
13 III. SETTING THE TIME FORMAT 1. Press and hold the “SET” button for 5 seconds. 2. “12:h” will begin to flash. 3. Press and release the “RESET/+” button to select y our desired time format.
14 5. Press and release the “RESET/+” button to select your desired temperature format. 6. Press and release the “S ET” button to advance to the time setting or wait 15 seconds for the display to return to the normal mode. V. SETTING THE TIME 1.
15 move to the minute setting. 7. The minutes will begin to flash. 8. Press and release the “RESET /+” button to set the minutes. 9. Press and release the “S ET” button to advance to the time setting or wait 15 seconds for the display to return to the normal mode.
16 FEATURES A. MINIMUM AND MAX IMUM TEMPERATURES 1. Press and release the “ MIN/MAX” button, “MIN” appears above and to the right of each temperature and the recorded minimum temperatures are displayed along with the time of the recorded minimum outdoor temperature.
17 temperature and the recorded maximum tempera t ure s a re di spl a y ed along with the time of the recorded maximum outdoor temperature. Please note that the flashing time is the tim e of the recorded outdoor temperature minimum or maximum.
18 additional remote sensor units with the WS-7136U. These extra sensors can be purchased through the same dealer as this unit, or by contacting La Crosse Technology directly.
19 1. It is necessary to remove the batteries from all units currently in operation. 2. Remove the battery covers to all remote sensor units. 3. Place all remote sensor units in a numeric sequential order.
20 D. VIEWING AND OPERATING WITH MULTIPLE REMOTE SENSOR UNITS 1. To view the temperature of a different remote sensor unit, press and release the “CH” button. A shift from one “boxed” number to the next should be observed in the OUTDOOR LCD. 2.
21 MOUNTING Note: To achieve a true temperature reading, avoid mounting in direct sunlight. We recommend that you mount the remote temperature sensor on an outside North- facing wall. The sending range is 80ft; obstacles such as walls, concrete, and large metal objects will reduce the range.
22 B. THE TEMPERATURE STATION 1. The indoor temperature station comes with the table stand already mounted. If you wish to use the table-stand, all that is required is to place the indoor weather station in your desired location. 2. To wall mount: a) Remove the table stand by pulling down on the stand from the rear and rotating forward.
23 TROUBLESHOOTING NOTE: For problems not solved, please contact La Crosse Technology via e-mail or phone, or visit our website, www.lacrossetechnology.com Problem: The LCD is faint Solution: Replace batteries Problem: No outdoor temperature is displayed.
24 3) Once the system has been reset and you have a temperature reading from the sensor, temporarily place the remote temperature sensor in the previous location.
25 Problem: Temperatures do not match if units are placed next to each other. Solution: Each temperature sensor is manufactured to be accurate to within 2 degree plus or minus and under normal conditions. It is possible for two temperature sensors to be as m uch as 4 degrees different.
26 compensate for the above factors and obtain an accurate comparison. MAINTENANCE AND CARE INSTRUCTIONS • Extreme temperatures, vibration, and shock should be avoided to prevent damage to the units. • Clean displays and units with a soft, damp cloth.
27 SPECIFICATIONS Transmitting Frequency 433MHz Measuring Range - Temperature Indoor Temperature Station: Indoor 32 ° F to 140 ° F with 0.1 ° F resolution.
28 Indoor Temperature Station 2 x AAA, 1.5V Dimensions: (H x W x D) Indoor Temperature Station 4.75” x 3.15” x 0.85” (excluding table stand) (120 x 80 x 21.
29 purchase to La Crosse Technology, Ltd or La Crosse Technology, Ltd’s aut horized service center. La Crosse Technology, Ltd will repair or replace this product, at our option and at no charge as stipulated herein, with new or recondit ioned parts or products if found to be defective dur ing the limited warranty period specified above.
30 (2) damage occurring during shipment (claims must be presented to the carrier); (3) damage to, or deterioration of, any accessory or decorativ e surface; (4) damage result ing from failure to follo.
31 may also have other rights spec ific to y our State. Some States do no allow the exclusion of consequential or incidental dam ages therefore the above exclusion of limitation may not apply to y ou. For warranty w ork, technic al support, or information contact: La Crosse Technology 2809 Losey Blvd.
32 interference, and (2) th is device must accept any interference received, including interference that may cause undesir ed operation. Freq. 433.92 MHz La Crosse Technology Made in China WS-7136U FCC ID: OMO-01RX (Receiver) OMO-01TX (Sensor) 081303 All rights reserved.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté La Crosse Technology WS-7136U c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du La Crosse Technology WS-7136U - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation La Crosse Technology WS-7136U, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le La Crosse Technology WS-7136U va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le La Crosse Technology WS-7136U, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du La Crosse Technology WS-7136U.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le La Crosse Technology WS-7136U. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei La Crosse Technology WS-7136U ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.