Network Mana geme nt Card & Mod bus/ Jbus (66123) Installation manu al.
2 - 3402230800/ AC.
3402230800/A C - 3 The Ne twork Manage ment Card & Modbus/Jbus (66123) is reco mmended for c entral UPSs protecting entire networks or for UPS units backing up critical loads.
4 - 3402230800/ AC . ETHERNET port Servi ce port (Settings/Senso r) OVERVIEW INDICATIONS LED Colour Status Description ACT Green ◗ OF F ◗ ON ◗ Flash ing ◗ Card not conne cted to network ◗ Ca.
3402230800/A C - 5 The Network Management Card & Modbus/Jbus (66123) can be hot-plugged in MGE TM Galax y TM 7000 equipped with a Minislot. It is not necessary to s hutdown the UP S, disconnect the load or restart the UPS. ◗ Note the M AC address of the card before inserting it.
6 - 3402230800/ AC The card is co nfig ured by defau lt wit h t his se rvice e nabled. No manual confi gurati on is requ ired.Th e IP paramet ers are aut omatical ly colle cted by the car d. From the main configuration menu: (see above) ◗ Pr ess the 2 k ey ( Net work conf igura tio n).
3402230800/A C - 7 To check whether the Network Management Card & Modbus/Jbus (66123) is oper ationa l after insta llation and conf igurat ion, proceed as fol lows. ◗ Run a brows er ◗ Enter in the address bar: http://IP address/ (e.g. http://172.
8 - 3402230800/ AC The Environment sensor is a Network Mana gement Card & Modbus/ Jbus option. The sensor remotely monitors the UP S environment by regularly measuring the temperature and humidity, and checking the states of two external conta cts.
3402230800/A C - 9 RS232 link con figuration and conn ection RS485 link con figuration and conn ection For proper operation, the polarity of EIA RS485 2-wire and 4-wire lines must be set at only one point and the lines terminated at the end. Polar ity Normally, the ma ster of the network s ets the polarity of the line.
10 - 3402230800 /AC 2 wires con nect ion Card settings of an interme diate cabin et Ot hers set ting s SA1 SA2 SA1 OFF ON 1 8 SA2 OFF ON 1 8 SA2 SA2 SA2 SA1 SA1 SA1 5 L + 43 2 1 L - 5V Rp Ra Rp 0V Ra .
3402230800/A C - 11 4 wires con nect ion Card settings of an interme diate cabin et Ot hers set ting s SA1 SA2 5 R- 43 2 1 R + T - T + SA1 OFF ON 1 8 SA2 OFF ON 1 8 SA2 SA2 SA2 SA1 SA1 SA1 5V Rp Rp 0V.
12 - 3402230800 /AC Configuration of the JBUS/MO DBUS commun ication p aram eters ◗ Use the cord supplied wit h the card ◗ Connect the card to a computer ◗ Use a terminal emulator such as HyperTerm inal TM with these settings "Echo typed characters locally" option: disabled ◗ Check t hat UPS power is on.
3402230800/A C - 13 ◗ Press the 2 key (Modifiy Jbus settings) ◗ Pr ess «R etur n» k ey to modi fy the Jbu s set tings * Hex for ma t. ◗ Press t he 0 key (Exit). ◗ Press t he 0 key (Exit). ◗ Run a brows er ◗ Enter in the address bar: http://IP address/ (e.
14 - 3402230800 /AC ◗ Set the par ameters. ◗ Select the «Save» button to save the new parameters..
3402230800/A C - 15 TECHNICAL CHARACT ERISTICS Physical characteristics Dimensions (W x D x H) 132 x 66 x 42 mm Weight 70 g RoHS 100% compatible Storage Storage tempera ture ra nge -10°C to 70°C Ambient c onditions Oper atin g t emp erat ure ran ge 0°C to 40° C Relative humidity 90% RH max.
3402230800/AC 990-3402230800 AC When cor rectly installed and used in accordance with manufacturer instruc tions, the card complies with the following standards: ◗ ITE (Information Technology Equipm.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté APC 66123 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du APC 66123 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation APC 66123, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le APC 66123 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le APC 66123, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du APC 66123.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le APC 66123. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei APC 66123 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.