CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM APC Smart-UPS RT BID SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM H. Configuration Specifics: The UPS is available in one of the following configurations: MODEL SKU # TOWER APC Smart-UPS RT 3000VA RM 230V SURT3000XLI .
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM A. Online: The input PFC power stage and the output power stage (inverter) shall operate in an on-line manner to continuously re gulate power to the critical load.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM 2.1 MECHANICAL DESIGN A. The UPS is contained in a rugged steel cabinet with two plastic front bezels; B. The UPS dimensions are 13 x 43 x 66cm (5.1 x 17 x 26 in.); C. The UPS cabinet is capable of conversion between Tower and Rack-Mount configurations; 2.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM 3. Output frequency: 50/60 +/- 3Hz tracking or 5 0/60 +/- 0.1Hz tracking (user selectable); 4. AC output voltage distortion: Max. 2% @ 100% linear load; Max. 5% @ 100% non-linear Load; 5. AC output static voltage regulation: +/-1%; 6.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM C. Input Current Limit: 1. The input converter shall control and limit the input current draw from utility to 150% of the UPS output.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM condition is removed from the critical bus output of the system. Automatic transfers of load to bypass also take place if for any reason the UPS cannot support the critical bus.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM 6. Self-diagnostics, self-test and proactive fault detection; 7. Communication to the host server via serial port; 8. Communication to the Network Interface Card or another SmartSlot accessory card if equipped.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM 6. The UPS is in fault state; 7. The battery needs to be replaced; 8. The battery capacity/utility voltage LED bar G. Audible Alarms: Using audio signal, the UPS will notify the user about important events.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM 3.2 SOFTWARE AND CONNECTIVITY A. Network Adaptor: APC SmartSlot Network Ma nagement Card shall allow one or more network management systems (NMS) to monitor and m anage the UPS in TCP/IP network environments.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM 7. TurboLinux v.7.0 and 8.0 8. Novell Netware 6.0 with Support Pack 1 9. Novell Netware 6.5 10. Novell Netware 5.1 with Support Pack 3 or above (using PowerChute Business Edition v6.2.2 agent) 11. Sun Solaris 8 and 9 PART 4 - Part 4 - EXECUTION 4.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM 1. Ensure proper system start-up. 2. Verify proper firmware control functions. 3. Verify proper firmware bypass operation. 4. Verify proper bypass switch operation (where applicab le). 5. Verify proper inverter operation and regulation circuits.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM identification and operation, system controls and adjustment, preventative maintenance, and troubleshooting.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté APC 5000VA c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du APC 5000VA - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation APC 5000VA, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le APC 5000VA va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le APC 5000VA, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du APC 5000VA.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le APC 5000VA. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei APC 5000VA ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.