Solar W a ter Pumping Products Ca t alog.
SD 6 - 35 PUMP Maximum Pump V oltage: 30 V olts Maximum T otal D ynamic Head: 35 Meters (115 Feet) Flow at F ull Depth: 6.0 lpm (1.6 gpm) SD 3 - 70 PUMP Maximum Pump V oltage: 30 V olts Maximum T otal D ynamic Head: 70 Meters (230 Feet) Flow at F ull Depth: 3.
Greetings T able of Contents SD Diaphragm Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 CD 300 Diaphragm Pump C ontroller . . . . . . . . . . . . . . . . . . . 3 SC Centrifugal P umps . . . . . . . . . . . . . . . . . . . . .
2 SD Diaphr agm Pumps ■ Solar W ater Pumping Products Ca t alog ■ ▼ W a ter Deliver y up to 4.5 gpm /17.0 lpm, Pumping R ange 0-230 feet / 0-70 meters Highest Quality Submersible Pump in its Cla.
CD 300 Diaphr agm Pump Controller 3 ■ Solar W ater Pumping Products Ca t alog ■ Description V alue Maximum Ambient T emperature 50° C Minimum Ambient T emperature -20° C Maximum Solar/Input V oltage (total VOC @ -20° C) 50 V olts Max. Output C urrent - Current Boost Mode (input voltage greater than output voltage) 10 Amps Max.
4 SC Centrifugal Pumps ■ Solar W ater Pumping Products Ca t alog ■ ▼ W a ter Deliver y up to 43 gpm /162 lpm, Pumping R ange 0-525 feet / 0-160 meters Brushles s, Permanent Magnet Motor with Mul.
CC 2000 Centrifugal Pump Controller 5 ■ Solar W ater Pumping Products Ca t alog ■ C C 2000 Pump C ontroller ▼ ▼ ▼ ▼ ▼ ▼ ▼ ▼ F or SC Series Pumps A ccommod a tes Arr a ys with two t.
6 K y ocer a Solar Modules and Interconnects / MC Connectors ■ Solar W ater Pumping Products Ca t alog ■ Model K C125G K C120 K C80 K C70 K C60 K C50 K C40 Rated P ower ( Watts) 125.0 120.0 80.0 70.0 60.0 50.0 40.0 Current at Max. Power (Amps) 7.2 7.
Balance of System 7 ■ Solar W ater Pumping Products Ca t alog ■ T rackers ▼ ▼ P as sive tr ackers c an increase wa ter deliver y b y 50% or more A djust able single-axis p assive solar tr acker follows the sun b y hea ted liquid flowing between east and west sealed canisters Unirac T racker 200 - 2.
8 Balance of System ■ Solar W ater Pumping Products Ca t alog ■ SD 12-30 Drop Kit ▼ ▼ ▼ ▼ 3/4" Pol yethylene tube Pump cable – red, black and green color code Safety rope 3/4" NPT fit ting kit (hose barb, hose clamp, 90° elbow) 50’ T ube, 75’ 12-2 Cable .
SD 6-35/3-70 Sand Shroud ▼ ▼ ▼ ▼ ▼ ▼ Elimina tes destructive sand intrusion Easy inst alla tion incl uding retrofit Constructed of rugged PVC and Pol yethylene Reus able nylon coa ted st ainles s steel ties included Dimensions: 4.5” OD x 30.
10 SD Pump Sizing ■ Solar W ater Pumping Products Ca t alog ■ Designing a Solar Pumping System There are man y aspects of designing a solar pumping system. This guide provides the inf ormation to correctly select a pump , controller , sensors, solar array , wiring, and pipe.
SD Pump Sizing 11 ■ Solar W ater Pumping Products Ca t alog ■ NOTE: 1. SD series systems require a CD 300 Pump Controller to provide the performance as shown. 2. Single, 12 V olt module systems require CD 300 Pump C ontroller to operate at full pow er .
■ Solar W ater Pumping Products Ca t alog ■ NOTE: 1. SD series systems require a CD 300 Pump Controller to pro vide the per formance as shown. 2. Single, 12 V olt module systems require CD 300 Pump C ontroller to operate at full pow er . 3. Systems using 2 solar modules should be wired with the solar modules in series.
■ Solar W ater Pumping Products Ca t alog ■ NOTE: 1. SD series systems require a CD 300 Pump Controller to pro vide the per formance as shown. 2. Single, 12 V olt module systems require CD 300 Pump C ontroller to operate at full pow er . 3. Systems using 2 solar modules should be wired with the solar modules in series.
■ Solar W ater Pumping Products Ca t alog ■ NOTE: 1. SD series systems require a CD 300 Pump Controller to pro vide the per formance as shown. 2. Single, 12 V olt module systems require CD 300 Pump C ontroller to operate at full pow er . 3. Systems using 2 solar modules should be wired with the solar modules in series.
■ Solar W ater Pumping Products Ca t alog ■ Canada and USA Sun Hours On Tilt (S.H.O .T .) Maps June 55 ° FS 50 ° FS 45 ° FS 40 ° FS 35 ° FS 30 ° FS 25 ° FS 20 ° FS 15 ° FS 15 ° FS 15 ° .
16 W arr anty and R eturn Informa tion ■ Solar W ater Pumping Products Ca t alog ■ W arranty T erms and Conditions W arranty P erformance Every product offered is fully guaranteed b y the manufacturer . The complete warranty detail of each product is available upon r equest.
.
7812 East Acoma Drive Scottsdale, AZ 85260 USA 480 .951.6330 F AX: 480 .951.6329 800 .544.6466 www .kyocerasolar .com.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Kyocera 85221 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Kyocera 85221 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Kyocera 85221, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Kyocera 85221 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Kyocera 85221, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Kyocera 85221.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Kyocera 85221. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Kyocera 85221 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.