Manuel d'utilisation / d'entretien du produit Thermostatic Electric Shower du fabricant Kohler
Aller à la page of 32
1 These instructions are to be left with the user Installation & User Guide Mira Azora Thermostatic Electric Shower.
2 Contents Introduction ................................................................................................ 3 Important Safety Information ..................................................................... 4 Pack Contents Checklist ...
3 Introduction Thank you for purchasing a quality Mira product. T o enjoy the full potential of your new product, please take time to read this guide thoroughly . Having done so, keep it handy for future reference. The Mira Azora is a thermostatic electric shower with separate controls for power selection and temperature/ow adjustment.
4 Important Safety Information W arning! Follow all warnings, cautions and instructions contained in this guide, and on or inside the appliance. 1. Products manufactured by us are safe and risk-free, provided that they are installed, used and maintained in good working order , in accordance with our instructions and recommendations.
5 Caution! 1. Read all of these instructions and retain this guide for later use. 2. The electri cal installation must co mply to “BS 7671 - Requir ements for Electrical Installations”, commonly referred to as the IEE Wiring Regulations - Part 7, or any particular regulations and practices, specied by the local electricity supply company .
6 Pack Contents Checklist Mira Azora T ick the appropriate boxes to familiarise yourself with the part names and to conrm that the parts are included.
7 Mira Energise Electric Shower Fittings T ick the appropriate boxes to familiarise yourself with the part names and to con - rm that the parts are included.
8 Installation Requirements 1. Plumbing Minimum maintained inlet pressure 70 kPa (0.7 bar). 100 kPa (1.0 bar) recommended for satisfactory operation. Maximum static inlet pressure 1000 kPa (10 bar). Minimum static pressure 20 kPa (0.2 bar) to keep the inlet valve closed.
9 Avoid layouts where the shower hose will be sharply kinked. This may reduce the life of the hose. A Hose Retaining Ring is supplied to prevent the handset from dropping below the spill-over level of the bath or shower tray , which could lead to contamination from back-siphoning.
10 In a domestic installation, the rating of the electricity supplier ’s fuse and the consumer unit must be adequate for the additional demand. All Mira electric showers are high power units, it is essential to contact your electricity supplier to ensure that the supply is adequate for the product.
1 1 Double-pole Isolating Switch Consumer Unit Installation W arning! T urn off the electrical and water supplies before proceeding with the installation of the Mira Azora. The electricity must be turned off at the mains and the appropriate circuit fuse removed, if applicable.
12 Drill and plug the top two xing holes. Secure the appliance to the wall with the screws provided. Drill the bottom xing hole with the product in place. Alternative xings (not supplied) may be necessary for some wall structures. Avoid drilling into any supply cable/pipe.
13 Feed cable into Case. Fit Earth sleeve (not supplied) and then strip insulation. Do not twist cable cores. L = BROWN E = GREEN/YELLOW N = BLUE Ret the Cover , making sure it is correctly located. Do not overtighten screws. Caution! Handle glass cover assembly with care.
14 Cold W ater Supply Pipe (Bottom Entry) Fixing Screw Holes For Cover Retaining Screws Electrical Supply Cable T erminal Block Inlet Connector Assembly Heater T ank.
15 Decide on a suitable position for the slide bar avoiding buried cables and pipes. Drill the two 7.0 mm xing holes for the slidebar at 600 mm centres and insert the wall plugs. Assemble the clamp bracket components. Push the plastic slidebar ends into the slidebar .
16 600 mm End Support Cap End Support Fixing Screw Slidebar End Clamp Bracket Assembly Soap Dish Slidebar Handset Hose Retaining Ring.
17 Commissioning If you are unsure how an electric shower works, please read through the section “User Instructions” before continuing. T urn control to full cold. T urn the water supply fully on. Check for water leaks. Set control to ‘I’. Switch on electrical supply .
18 The temperature will rise further . Adjust temperature as required. Flow rate will adjust automatically . The shower will purge from its tank for a few seconds. Residual water may drain over a few minutes. Set control to ‘III’. 5 - 10 Secs 0 - 5 Secs 13.
19 User Instructions Read the section “Important Safety Information” rst. Note! At the end of every shower make sure that the shower head points into the catchment area. A small amount of water may be retained in the shower handset after the shower has been turned off.
20 Spray Action The handset spray head has four different spray actions:- Eco, Start, Soothe and Force. The handset operation is described below . 1. Eco T o access the eco setting, turn the spray plate fully clockwise. W ater will ow from the outer set of holes at a reduced ow rate.
21 Handset dripping. OFF Any Insufcient W ater supply pressure for shut off. Inlet V alve faulty . The minimum static pressure to ensure shut off and prevent dripping is 0.2 bar . Note: If other appliances are operating, static pressure may drop below 0.
22 Insufcient water supply pressure/ow for operation. Contact local water company . Supply pressure must be a minimum of 0.7 bar . Note: If other appliances are operating, pressure may drop below 0.7 bar . Power Light Heater Setting Low/Medium/ High Probable Cause Possible Remedy Symptom Low or No ow ON Any Other outlets (e.
23 Appliance fails to produce hot water when set on Medium/ High Heater Setting. ON II/III Heater T ank failure. Contact local water company . Replace. Supply pressure below 0.2 bar . Contact local water company . Check mains water static pressure. Any ON ON II/III ON II/III Possible failure of the Microswitch or thermal switch.
24 Make sure that the electrical supply is turned off at the mains and that the water supply is fully turned off. Hold a wrench across the ats of the metal connector . Unscrew the lter using another wrench as shown. Clean or renew the Filter as necessary .
25 Spare Parts List.
26 DCV -H: An outlet double check valve, designed to prevent the backow or backsiphonage of potentially contaminated water , through shower controls which are tted with a exible hose as part of the outlet shower tting. Available as an optional accessory from your Mira Showers stockists.
27 Mira Azora Spare Parts Diagram 405.58 406.27 416.38 416.41 416.48 416.51 872.01 872.28 1563.507 1563.539 A A A A A A A A A A 1563.534 1563.519 1634.
28 Mira Energise Shower Fittings Spare Parts List 449.03 Slidebar W all Fixing Assembly 632.73 Hose Seal (x2) 126.65 Slidebar Ends 449.02 Slidebar 449.04 Soap Dish 449.05 Hose 449.01 Clamp Bracket Assembly 1563.592 Handset 1563.594 Hose Retaining Ring 1563.
29 Dimensions 100 mm 77 mm 233 mm 367 mm 69 mm 660 mm 600 mm.
30 Wiring Diagram Thermal Cutout Dual Disc T ank Connection Load Inlet Connector Pressure/Power Selector Switch Solenoid V alve Power On L.E.D. ST ART/STOP L E N Internal Wiring Diagram.
31 Spare Parts We maintain an extensive stock of spares, and aim to provide support throughout the product’s expected life. Spares can be purchased from approved stockists or merchants (locations on request) or direct from Customer Services. Spares direct will normally be despatched within two working days.
32 1062243-W2-A (J95L) © Kohler Mira Limited, September 2006 Mira Showers Kohler Mira Ltd Cromwell Road, Cheltenham GL52 5EP . Mira is a registered trade mark of Kohler Mira Limited. The company reserves the right to alter product specications without notice.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Kohler Thermostatic Electric Shower c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Kohler Thermostatic Electric Shower - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Kohler Thermostatic Electric Shower, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Kohler Thermostatic Electric Shower va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Kohler Thermostatic Electric Shower, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Kohler Thermostatic Electric Shower.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Kohler Thermostatic Electric Shower. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Kohler Thermostatic Electric Shower ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.