Manuel d'utilisation / d'entretien du produit KAC-PS501F du fabricant Kenwood
Aller à la page of 15
KA C-PS501F © B64-1444-00 (EM) 4-CHANNEL POWER AMPLIFIER INSTR UCTION MANU AL.
2 English Saf ety pr ecautions Installation pr ocedur e Since there are large variety of settings and connections possible according to applications, read the instruction manual well to select the proper setting and connection. 1. Remove the ignition key and disconnect the negative - terminal of the battery to prevent short circuits.
English 3 Installation • Since the power amplifier has no parts which require operation, it can be installed at a position away from the driver’s seat without any hindrances. As generally accepted positions for its installation, places such as inside the trunk, etc.
4 English Contr ols This is a 4 channel amplifier including 2 stereo amplifiers in a body. One amplifier is referred to as amplifier A and the other is amplifier B. This unit is compatible with a large variety of systems by combining the switches and functions described in the following.
@ INPUT SELECTOR switch This switch selects the input method of the signals to be amplified by amplifiers A and B. • A B position: Amplifies both of the signals input to amplifiers A and B. • A position: Amplifies only signal input amplifier A with both amplifiers A and B.
6 English B .M.S. (Bass Manag ement Syst em) AIR INDUCTION LO PASS 50 50 200 200 HI PASS LO PASS 50 50 200 200 HI PASS FILTER FREQUENCY A B POWER L R L R LINE IN P.
English 7 ■ If the unit is going to be operated from the centre unit: The amount of bass boost and the opening/closing of the slide panel can be controlled from the centre unit. Additionally, up to 3 power amplifiers can be set at the same time. Kenwood centre units released in 1999 or later having an “EXT.
8 English Indicat or AIR INDUCTION LO PASS 50 50 200 200 HI PASS LO PASS 50 50 200 200 HI PASS FILTER FREQUENCY A B POWER COOLING FAN OPERATION / PROTECTION OPEN / CLOSE LOW VOLTAGE B.M.S. 4 / 3 / 2 CHANNEL POWER AMPLIFIER COOLING FAN OPERATION / PROTECTION OPEN / CLOSE LOW VOLTAGE B.
English 9 Connection ■ Power cable connection To prevent fire caused by a short in the wiring, connect a fusible link or breaker nearby the battery’s positive terminal. Wiring • If a buzzing noise is heard from the speakers when the engine is running, connect a line noise filter (optional) to each of the battery cable.
10 English L R L R LINE IN P.CON EXT.AMP.CONT. GND MONO LINE OUT 25Hz 15Hz INFRASONIC FILTER OPERATION OFF 0.2 0.5 5 1 2 3 4 B B A A + (MAX) (MIN) 25Hz 15Hz INFRASONIC FREQ (Hz) FREQ (Hz) OFF LPF OFF HPF MONO STEREO FILTER LPF OFF HPF OPERATION MONO STEREO B.
English 11 LEFT BRIDGED RIGHT SPEAKER OUTPUT FUSE(20A × 4) BATT. GND B B A A 20 20 20 20 A B BRIDGED R L LEFT BRIDGED RIGHT SPEAKER OUTPUT FUSE(20A × 4) BATT.
12 English Connection S ystem examples L R L R L R L R L R LINE OUT A B L R 25Hz 15Hz INFRASONIC FILTER OPERATION OFF 0.2 0.5 5 1 2 3 4 (MAX) (MIN) 25Hz 15Hz INFRASONIC FREQ (Hz) FREQ (Hz) OFF LPF OFF HPF MONO STEREO FILTER LPF OFF HPF OPERATION MONO STEREO INPUT SELECT A AB CONTROL INPUT SENSITIVITY(V) 0.
English 13 S ystem examples L L L R L R L R L R L R LINE OUT A B C C 25Hz 15Hz INFRASONIC FILTER OPERATION OFF 0.2 0.5 5 1 2 3 4 (MAX) (MIN) 25Hz 15Hz INFRASONIC FREQ (Hz) FREQ (Hz) OFF LPF OFF HPF MONO STEREO FILTER LPF OFF HPF OPERATION MONO STEREO INPUT SELECT A AB CONTROL INPUT SENSITIVITY(V) 0.
T r oubleshooting Guide What might appear to be a malfunction in your unit may just be the result of slight misoperation or miswiring. Before calling service, first check the following table for possible problems. PROBLEM POSSIBLE CAUSE SOLUTION No sound.
English 15 Specifications Specifications subject to change without notice. Audio Section Max Power Output (4 Ω ) 4 Channel Mode ........................................................................................................150 W × 4 3 Channel Mode.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Kenwood KAC-PS501F c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Kenwood KAC-PS501F - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Kenwood KAC-PS501F, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Kenwood KAC-PS501F va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Kenwood KAC-PS501F, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Kenwood KAC-PS501F.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Kenwood KAC-PS501F. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Kenwood KAC-PS501F ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.