Manuel d'utilisation / d'entretien du produit 625.385700 du fabricant Kenmore
Aller à la page of 24
OWNER'S MANUAL MODEL NO. UltraFilter 150 625.385700 UltraFilter 350 625.385720 Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. If you have questions when installing, operating or maintaining your reverse osmosis system, call this toll-free number.
- WARRANTY- F iiiiiiiii iiiiiiiiiiii iiiiiiii _ FULL WARRANTY ON REVERSE OSMOSIS DRINKING WATER SYSTEM I I i (except filter cartridges and R. O. membrane) i i For one year from the date of purchase, w.
- TABLE OF CONTENTS - Where To Install the RO System ............ 4 Tools and Materials Needed ............... 4 6 Steps to Install ......................... 4 Install Cold Water Supply Fitting ......... 5 Install Drain Adapter ................... 6 Install Faucet .
- WHERE TO INSTALL THE RO SYSTEM - The RO assembly and storage tank is designed for installation under the sink, usually in the kitchen or bathroom. The RO assembly mounts on a wall sur- face, or can lay on the cabinet floor next to the storage tank. Hanger washers and wood screws are included for cabinet wall mounting.
- STEP 1: INSTALL COLD WATER SUPPLY FITTING - Check and comply with local plumbing codes as you plan, then install a cold feed (supply) water fitting. The fitting must provide a leak-tight connection to the RO 1/4" tubing (see Figure 10, page 10).
- STEP 2: INSTALL DRAIN ADAPTER - • Note: Running the drain tubing directly to a floor drain, sump, standpipe, laundry tub, etc., as shown on page 19, is preferred. However, if that is not pos- sible or practical, the included drain adapter installs in the sink drain pipe, always above or ahead of the p-trap, Figure 4.
- STEP 3: INSTALL FAUCET (cont.)- B. ASSEMBLE FAUCET ULTRAFILTER 150 1. Loosely assemble the base, spacer, washer and plastic nut onto the faucet stud. 2. Route the 1/4" red tubing through the sink or countertop hole and connect to 1/4" barb on faucet.
- STEP 3: INSTALL FAUCET (cont.)- B. ASSEMBLE FAUCET ULTRAFILTER 350 1. Remove the nut from the faucet threads. 2. Remove the spacer from the threads. To do this, place a finger on either side of the threads and gently press thumb against the bottom of the faucet threads (where the quick connect is).
- STEP 3: INSTALL FAUCET (cont.)- UltraFilter 350 channel locking tabs valve lever FAUCET ELECTRONICS The faucet will measure the length of time the filters have been installed (6 months). The faucet has an in- dicator LED that flashes to inform you of the status of the filter.
- STEP 5: INSTALL STORAGE TANK, MAKE REMAINING TUBING CONNECTIONS - 1. CONNECT DRAIN TUBING, FAUCET TO DRAIN ADAPTER: Referring to Figure 10, run the loose section of black 3/8" tubing from the faucet to the drain adapter, with a black collet, installed on page 6.
- STEP 6: SANITIZING, PRESSURE TESTING & PURGING - SANITIZING Sanitizing is recommended upon installation of the RO system, and after servicing inner parts. It is im- portant for the service person to have clean hands while handling inner parts of the system.
- HOW YOUR REVERSE OSMOSIS SYSTEM WORKS - PREFILTER Water from the cold supply pipe enters the RO as- sembly prefilter first (Figure 10, page 10, and sche- matic, page 13). The prefilter has a replaceable sediment cartridge with activated carbon in its composition.
- HOW YOUR REVERSE OSMOSIS SYSTEM WORKS - PRODUCT WATER c_--_-'-. FAUCET t air gap t %r%'Y " 2 REVERSE OSMOSIS WATER FLOW SCHEMATIC BLUE _ PRODUCT WATER ] -o RED I drain flow I control .
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - PREFILTER AND POST FILTER CARTRIDGES You must replace the pref!lter cartridge often to pro- tect the RO membrane from being destroyed by chlorine, and/or from plugging with sediments in your water supply.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - RO MEMBRANE CARTRIDGE The life of the RO membrane cartridge depends mostly on the pH of the supply water to the RO sys- tem (see specifications). Cartridge life is shorter with higher pH. For example, if supply water pH is flom 6.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - TUBING CONNECTION (all push- in fitting locations) This RO system includes push-in fittings for quick tubing connection at most locations. If working with the fittings, do the following. Connection (Figure 14): 1.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - REVERSE OSMOSIS SYSTEM CARE GUIDE MODEL NOs. 625.385700 & 625.385720 1. AT LEAST every 6 months, replace the prefilter and postfilter cartridges or when red LED flashes, 2.
- DIMENSIONS and SPECIFICATIONS - 11" 13" Supply water pressure limits ........................ 40 - 100 psi Supply water temperature limits ..................... 40 - 100 °F Maximum total dissolved solids (TDS) ............... 2000 ppm Maximum water hardness @ 6.
- REMOTE INSTALLATION LOCATIONS - Possible remote locations for the RO nearby the kitchen or bathroom sink include; (1) a basement area underneath the sink, and (2) an adjacent room or closet. Longer lengths of tubing (see parts list on page 20) may be needed.
- REPAIR PARTS - 17 Z O 16 I 8 Kenmore Reverse Osmosis Drinking Water System, Model Nos. 625.385700 & 625.385720 6 7 b @ 19_i ....... • C 0 _J / 14 13 -.
- REPAIR PARTS - Kenmore Reverse Osmosis Drinking Water System, Model Nos. 625.385700 & 625.385720 Key Part Description of Part No. Number 1 7221128 Sump (3 req.) 2 7223633 O-Ring, 2-1/4" x 2-1/2" (3 req.) 3 9006062 Screw (2 req.) 4 9041700 Hanger Washer (2 req.
- NOTES- 22 Problems, Questions? Call 1-800-426-9345 Kenmore Water Line.
- NOTES- 23 Problems, Questions? Call 1-800-426-9345 Kenmore Water Line.
OWNER'S MANUAL MODEL NO. UltraFilter 150 625.385700 UltraFilter 350 625.385720 The model number of your reverse osmosis system is found on the rating decal.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Kenmore 625.385700 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Kenmore 625.385700 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Kenmore 625.385700, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Kenmore 625.385700 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Kenmore 625.385700, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Kenmore 625.385700.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Kenmore 625.385700. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Kenmore 625.385700 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.