Owner's Manual FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING Hodel No. 153o327165_' 30 GaT, Short 153327166 30 Gai Short 153327265 40 Ga! Short 153,327266_J 40 Gai Short 153,327365 30 Gat, 153327366 30 Ga{, 153327465 40 GaL 153.
Safety Precautions _WARNING ] Improper installation, adjustment, alteration, service or| maintenance can cause DEATH, SERIOUS BODILY INJURY,, | OR PROPERTY DAMAGE.
Table of Contents Safety Precautions ...................................................................................................................... 2 Table of Contents ...........................................................................
|ntroduction Thank You for purchasing a Seats water heater. Properly installed and maintained, it should give you years of trouble free service° If you should decide that you want the new water heater professionally installed, contact the local Sears Service Center or any Sears store.
Materials an Basic Materials Needed To simplifi t the installation Sears has available the inst£Iation parts shown below You may or may not need all of these materi- als, depending on your type of installation Tools eeded WATER HEATER INSTALLA. TION KIT WITH FLEXIBLE CONNECTORS FOR 3f4" OR 1/2" THREADED OR COPPER PLUHBING r .
Installation Instructions Removing the Old Water Heater Turn "OFF" electrical supply to the water heater. Q Turn "OFF" the water supply to the water heater at the water shutoffvalv.
installation instructions (toni'd) Facts to Consider About the Facts to Consider About The Location Convertible Lower Element You should carefully choose an indoor location for the new water heat.
installation Water Piping instructions (cont'd) AWARNING HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a tem- )erature which will satisfy space heating,.
IJnstallation Instructions (cont'd) Temperature=Pressure Relief Valve _k WARNIfNG At the time of manufacture this water heater was provided with a combination temperature-pressures relief valve c.
|nstallation Instructions (cont'd) Filling the Water Heater To fill the water heater with water: . Close the water heater drain valve by turning the handle to the right (clockwise).
Installation Instructions (cont'd) 2. The convertible element is located behind the lower access panel of the water heater, Remove the two screws securing the access panel, and remove panel, 5, Remove the screws from terminal 2 of the element, and move the looped end of the wire aside.
installation Converting the Lower Element (cont'd) 9, Replace terminal cover on thermostat making sure that the loddng tabs on the terminal cover are in place Instructions (cont'd) 12, Complete wiring to the water heater, or if completed, turn "ON" electric power to the water heater after filling the tank with water.
installation Wiling Diagrams STANDARD WIRING FOR 2 WIRE LEAD WATER HEATERS NON-SIMULTANEOUS OPERATION 240 VOLT DOUBLE ELEMENT Instructions (cont'd) TO ELECTRIC POWER SUPPLY UPPER E.CoO. & THERMOSTAT BUSS BAR FOR 5500 WATTS .I w BLACK RED UPPER ELEMENT .
installation Wiring Instructions (cont'd) IkCAUTION I Never use this water heater unless it is completely full of I water. To prevent damage to the tank and heating ele- I ment, the tank must be filled with water.
Installation Instructions installation Checklist (cont'd) • Whether or not the element conversion is made, the model rating plate must be marked. Using a hard point ink _en, check the appropriate block within the model rating p_ate, which is located adjacent to the lower access panel.
Service and Adjustment Temperature Regulation AWARNING HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a tem- perature which will satisfy space heating, clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact.
Service and Adjustment Lower Thermostat Adjustment The lower thermostat is adjustable if a different water tempera- ture is desired. Read all warnings in the 'Temperature- Regulation" section before proceeding.
Service and Element Cleaning/ Replacement Adjustment NOTE: These instructions are written for element cleaning and element replacement for the lower element.
6. Lift out the tab as shown to unclip file terminal cover from the thermostat. The terminal cover can now be removed from the thermostat.. TERHtNAL COVER PLASTIC TABS OH CLIPPED TO THER* BOTH BIDES OF HOSTAT AT THIS /TEKH|NAL COVER POINT HOLD IT IN PLACE LOWERTHERHOSTAT TERHINAL COVER ON UPPER THERHOSTAT 7.
Service Element Cleaning/ Replacement (cont'd) I6,, Replace terminal cover on thermostat maldng sure that the locldng tabs on the terminal cover are in place.
Troubleshooting Guide Start Up Conditions THERHAL EXPANSION Water supply systems may, because of such events as high line pressure, frequent cut-offs, the effects of water hammer among others, have installed devines such as pressure reducing vales, check valves, back flowpreventers, e_c .
Troubleshootin Guide Operational Conditions SMELLY WATER In each water heater there is installed at least one anode rod (see parts section) for corrosion protection of the tank. Certain water conditions wil! cause a reaction between this rod and the water.
Troubleshootin Guide (cont:'d) HIGH TEHPERATURE SHUT OFF SYSTEH (cont'd) , Remove the two screws securing the access panel and remove panel • Remove the insulation block to expose the open.
=rPou eshooting Guide (cont'd) Leakage Checkpoints Use this guide to check a "Leaking" water heater, Many suspect- ed "Leakers" are not leaking tanks, Often the source of the .
ores 25.
Pam'ts Order List KENMORE POWER MISEP- TM 9 ELECTRIC WATER HEATERS MODEL NUMBERS: 153o327165 30 Gal. Short 153.327166 30 GM. Short 153.327265 40 Gal. Short 153.327266 40 GaL Short NOTE:/[ UPPER ELEMENT. These water heaters are equipped with 3800 watt elements.
Parts Order List (cont'd) I_J_NMORE P&_ER MISER z_ 9 ELECTRIC W_-ER HEATEP_S MODEL _UMBEP_S: 153.327165 30 Gal. Shot* 153.327166 30 Gal. Short 153.327265 40 Gal. Short 153.327266 40 Gal. Short KEY PART NO. DESCRIPTION 1, Tempemmie-Pressure Relief Valve* 2.
Parts Order List (cont'd) KENMORE POWER MISER _ 9 ELECTRIC WATER HEATERS MODEl-. NUMBERS: 153.327365 30Gal. 153.327366 30GM. 153.327465 40GM_ 153.327466 40GM. 153.327565 50 GM° NOTE: A UPPER EleMENT: These water heaters are equipped with 3800 watt elements.
Parts Order List (cont'd) KENMORE POWER MISER _ 9 ELECTRIC WATER HEATERS MODEL. NUMBERS: 153.327365 30GaL 153.327366 30G a l, 153.327465 40Gal, 153.
Parts Order List (cont'd) I_NMORE POWER MISER m 9 ELECTRIC WATER HEATERS MODEL NUMBERS: 153.327566 50 GaL 153.327665 66 Gal. 153.327666 66 Gal. 153.
Parts rder List (cont'd) KENMORE POWER MISER TM 9 EI_CTRIC WATER HEATERS MODEL NUMBERS: 153.327566 50 Gal. 133.327665 66 Gal. 153.327666 66 Gal. 153.
Warranty About Your Warranty THE, PRICE OF YOUR _7_TI_R HEATER DOES NOT INCLUDE A FREE CHECKUP SFR'VqCE CA[.[. On Water Heater Installations Arranged By Sears, Sears warrants the installation. ON INSTALLATIONS NOT MADE BY SEARS AUTHORIZED CONTRACTORS: 1 Your Sears warranty applies to the product only 2 Sears does not warrant the installation.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Kenmore 153327265 40 GA! SHORT c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Kenmore 153327265 40 GA! SHORT - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Kenmore 153327265 40 GA! SHORT, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Kenmore 153327265 40 GA! SHORT va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Kenmore 153327265 40 GA! SHORT, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Kenmore 153327265 40 GA! SHORT.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Kenmore 153327265 40 GA! SHORT. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Kenmore 153327265 40 GA! SHORT ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.