Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A C3 T echnology ® Gas W ater Heaters meet the new ANSI Z21.10.1 standard that deals with the accidental or unintended ignition of ammable vapors, such as those emitted by gasoline. Owner ’ s Manual FOR POT ABLE W A TER HEA TING ONL Y .
2 SAFE INST ALLA TION, USE AND SERVICE Y our safety and the safety of others is extremely important in the installation, use and servicing of this water heater . Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential hazard.
3 SAFETY PRECAUTIONS.
4 T ABLE OF CONTENTS SAFE INST ALLA TION, USE AND SERVICE ...................................................................................................................... 2 SAFETY PRECAUTIONS .....................................................
5 Thank Y ou for purchasing a Kenmore water heater . Pro perly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears call 1-800-4-MY -HOME ® .
6 MA TERIALS AND BASIC TOOLS NEEDED Materials Needed T o simplify the installation Sears has available the installation parts shown below . Y ou may or may not need all of these materials, depending on your type of installation. W A TER HEA TER INST ALLA TION KIT WITH FLEXIBLE CONNECTORS FOR 3/4” (19.
7 TYPICAL INST ALLA TION GET TO KNOW YOUR W A TER HEA TER - GAS MODELS A V ent Pipe B Drafthood C Anode D Hot W ater Outlet E Outlet F Flexible W ater Connections G Gas Supply H Manual Gas Shut-off V alve I Ground Joint Union * INS T AL L IN ACC OR DA NC E WITH LOCAL CODES.
8 INST ALLA TION INSTRUCTIONS 1. Turn “OFF” the gas supply to the water heater . If the main gas line shutoff valve serving all gas appliances i s used, also shut “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation is completed, see Figures 2 and 3.
9 Facts to Consider About the Location Carefully choose an indoor location for the new water heater , because the placement is a very important consideration for the saf ety of the oc cup ants in th e build ing and for the most ec ono mic al use of the appliance.
10 Minimum clearances between the water heater and combustible construction are 0 inch at the sides and rear , 4 inches (102 mm) at the front, and 6 inche s (15 3 mm) from the vent pipe, see Figure 8. Clearance from the top of the jacket is 12 inches (305 mm) on most models.
1 1 • Do obtain new warning and instruction labels from Sears for placement on the blanket directly over the existing labels. • Do inspect the insulation blanket frequently to make certain it does not sag, thereby obstructing combustion air ow .
12 FIGURE 13. • Alternatively a single permanent opening may be used when communicating directly with the outdoors, or with spaces that freely communicate with the outdoors. The opening shall have a minimum free area of 1 square inch per 3,000 BTU per hour (8.
13 This water heater shall not be connected to any heating systems or component(s) used with a non-potable water heating appliance. All piping components connected to this unit for space heating applications shall be suitable for use with potable water .
14 Fit T & P valve insu lati on over valve . Mak e sur e that the ins ulat ion does not interfere with the lever or block the discharge opening of the T & P valve.
15 The temp era tur e-p res sur e reli ef val ve mus t be manu all y oper at ed at least once a year . Caution should be taken to ensure that (1) no one is in front of or around the outlet of the temp.
16 FIGURE 18. The vent pipe from the water heater must be no less than the diameter of the draft hood outlet on the water heater and must slope upward at least 1/4 inch per linear foot (21 mm per meter). See Figure 19. FIGURE 19. All vent gases must be completely vented to the outdoors of the structure (dwelling).
17 W ater heaters covered in this manual have been tested and approved for installation at elevations up to 7,700 feet (2,347 m) above sea level. For installation above 7,700 feet (2,347m), the wat er.
18 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a re or explosion may result causing property damage, personal injury or loss of life. • If you cannot reach your gas supplier, call the re department.
19 NOTE: A water temperature range of 120°F-140°F (49°C-60°C) is recommended by most dishwasher manufacturers. The thermostat of this water heater has been factory set at its lowest position (PILOT LIGHTING). It is adjustable and must be res et to the des ire d tem per atur e settin g to red uce the risk of scal d injury .
20 T ank (Sediment) Cleaning Sediment build-up on the tank bottom may create varying amount of noise and if left in the tank will cause permanent tank failure. In some water areas, you may not be able to drain all sediment deposits by simply draining the tank.
21 Housekeeping V acuum around base of water heater for dust, dirt, and lint on a regular basis. A T LE AS T ONC E EV ER Y SI X MON TH S A VIS UA L IN SPE CT IO N SHOULD BE MADE OF THE AIR INT AKE SCREEN.
22 Drain V alve W asher Replacement (See Figure 26) 1. Turn “OFF” gas supply to water heater . 2. Follow “Draining” instructions. 3. Turning counter clockwise ( ), remove the hex cap below the screw handle. 4. Remove the washer and put the new one in place.
23 TROUBLESHOOTING GUIDE Start Up Conditions Thermal Expansion W ater supply system may , because of such events as high line press ure, frequent cut-of fs and the effe cts of water hammer have ins tal led de vice s such as pre ssu re redu cin g valv es, che ck val ves , back ow preventers, etc.
24 Condensation Whenever the water heater is lled with cold water , some condensate will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensat ion. This usually happens when: • A new water heater is lled with cold water for the rst time.
25 Operational Conditions (Continued) Leakage Checkpoints FIGURE 28. Read this manual rst. Then before checking the water heater make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water .
26 These guidelines should be used by a qualied service agent. Call Sears Service at 1-800-4-MY -HOME ® (1-800-469-4663) for assistance. Inform the associate that this is a “Flammable V apor Ignition Resistant” Product. Problem Cause Solution Improperly sealed, hot or cold supply connection, T ighten threaded connections.
27 MODEL NOS. 153.339362 30 Gallon 153.339262 40 Gallon Short 153.339462 40 Gallon Now that you have purchased your gas water heater , should a need ever exist for repair parts or service, simply contact any Sears Service Center or call 1-800-4-MY -HOME ® (1-800-469-4663).
28 Now that you have purchased your gas water heater , should a need ever exist for repair parts or service, simply contact any Sears Service Center or call 1-800-4-MY -HOME ® (1-800-469-4663). Be sure to provide all pertinent facts when you call or visit.
29 * Not Shown. ** Includes Inner Door Gasket Model Numbers Key No. Part Description 153.339562 153.339762 153.339640 153.339680 1 Air Intake Screen 9003406 9003406 9003406 9003406 2 Anode Rod 9003650.
30 NOTES:.
31 NOTES:.
9 - YEAR LIMITED W ARRANTY ON W A TER HEA TER For nine years from the date of purchase, if this water heater is installed and operated in a single-family home in accordance with the owner ’s manual .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Kenmore 153.339962 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Kenmore 153.339962 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Kenmore 153.339962, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Kenmore 153.339962 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Kenmore 153.339962, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Kenmore 153.339962.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Kenmore 153.339962. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Kenmore 153.339962 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.