Manuel d'utilisation / d'entretien du produit 153.33115 du fabricant Kenmore
Aller à la page of 44
Use & Care Guide Model No. 153.331140 40 Gallon 153.331150 50 Gallon I<enmore L-oa of LOW LEAD COMPLIANT For potable water heating only. Not suitable for space heating. Not for use in mobile homes. INSTALLER: Affix these instructions to or near the water heater.
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard.
Read and understand instruction manual and safety messages before installing, operating or servicing this water heater. Failure to follow instructions and safety messages could result in death or serious injury. Instruction manual must remain with water heater.
SAFE INSTALLATION, USE AND SERVICE ................................................................................................. 2 SAFETY PRECAUTIONS .................................................................................................
OPERATING YOUR WATER HEATER ................................................................................................... 23-26 Lighting Instructions ...............................................................................................
12 -YEAR LIMITED WARRANTY ON WATER HEATER For twelve years from the date of purchase, if this water heater is installed and operated in a single-family home in accordance with the owner's manual .
Thank You for purchasing a Kenmore water heater. Properly installed and maintained, it should give you years oftrouble free service. If you should decide that you want the new water heater professionally installed by Sears call 1-800-4-MY-HOME ®. They will arrange for prompt, quality installation by Sears authorized contractors.
MODEL TANK CAPACITY TYPE INPUT RECOVERY MINIMUM DIAMETER DIMENSIONS NUMBER IN GALS (LTRS) OF RATE RATE GALS. VENT PIPE INCHES INCHES (mm) GAS (Btu/hr) PER HOUR DIA. INCHES (mm) HEIGHT TO @ 90°F RISE (mm) JACKET TOP 153.331140 40 (151) Natural 40,000 40.
MATERIALS NEEDED To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materials, depending on your type of installation. EXPANSION TANKS FOR THERMAL EXPANSION CONDITIONS AVAILABLE IN 2 GALLONS (7.
GET TO KNOW YOUR WATER HEATER - GAS MODELS A Vent Pipe B Draft Hood C Anode (Not Shown) D Hot Water Outlet E Insulation F Gas Supply Piping G Manual Gas Shut-off Valve H Ground Joint Union I Drip Leg .
This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor ignition incident. The new technology used in meeting these standards makes this product more sensitive to installation errors. Please review the following checklist and make any required installation upgrades or changes.
Removing the Old Water Heater C) O MANUAL GAS SHUT-OFF VALVE--_ GROU ND-------_ JOINT UNION CHECK WITH LOCAL UTILITY FOR MINIMUM HEIGHT 3"MINIMUM @ SUITABLE DRAIN DISCHARGE PIPE (DO NOT CAP OR PLUG) 6" MAXIMUM AIR GAP FIGURE 2. © © ® Turn "OFF" the gas supply to the water heater.
Location Requirements I Carbon Monoxide Poisoning Hazard Do not install in a mobile home. Doing so can result in carbon monoxide poisoning and death. area of the water heater, leave the area immediately and call the fire department from a neighbor's home.
Property Damage Hazard • All water heaters eventually leak. • Do not install without adequate drainage. Insulation Blankets Insulation blankets available to the general public for external use on gas water heaters are not necessary with Kenmore products.
F BACK SIDES TOP -- VIEW l -_ II _VENT S°ESlll" IH FIGURE 10. Open the cold water supply valve to the water heater. NOTE: The cold water supply valve must be left open when the water heater is in use. To ensure complete filling of the tank, allow air to exit by opening the nearest hot water faucet.
Gas Pressure Explosion Hazard • Gas leaks can not always be detected by smell. • Gas suppliers recommend that you use a gas detector approved by UL or CSA. • For more information, contact your gas supplier. • If a gas leak is detected, follow the "What to do if you smell gas" instructions on the cover of this manual.
Carbon Monoxide Warning Follow all the local and state codes or, in the absence of local and state codes, the "National Fuel Gas Code", ANSI Z223.1 (NFPA 54)- current edition to properly install vent system. Failure to do so can result in death, explosion, or carbon monoxide poisoning.
gas utilization equipment in the area. If you are unsure that the structure meets this requirement, contact your local gas utility company or other qualified agency for a safety inspection.
CONFINED SPACE 2000 BTUH 1 SQ. INCH PER 2000 BTUH ALL AIR FROM OUTDOORS USING HORIZONTAL DUCTS FIGURE 16. ALTERNATIVE OPENING LOCATION CONFINED SPACE 1SQ.
inspection, and replacement. Vent connectors cannot pass through any ceiling, floor, firewall, or fire partition. It is recommended (but not mandatory) that a minimum 12 inches of vertical vent pipe be installed on the draft hood prior to any elbow in the vent system.
Piping Installation Piping, fittings, and valves should be installed according to the installation drawing (Figure 22). If the indoor installation area is subject to freezing temperatures, the water piping must be protected by insulation. The water supply pressure should not exceed 80 psi.
Closed System/Thermal Expansion Property Damage Hazard • All water heaters eventually leak. • Do not install without adequate drainage. As water is heated, it expands (thermal expansion).
Lighting Instructions Read and understand these directions thoroughly before attempting to light or re-light the pilot. Make sure the view port is not missing or damaged. (See Figure 34.) Make sure the tank is completely filled with water before lighting the pilot.
BEFORE LIGHTING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES A. This appliance has.a .pi.Iot which is lit.by a piezo- elec_ncsparK gas j,gnluon system, uo n_.g.o_ qpen _ne inner aoor of me appliance and _ry _o IIgh_ the pilot by hand.
Checking the Draft Water Temperature Regulation Burn Hazard Do not touch vent. Doing so can result in burns. After successfully lighting the water heater, allow the unit to operate for 15 minutes and check the draft hood relief opening for proper draft (Figure 26).
Gas Control/Temperature Knob 120°F Status Mark W¢ Igniter Temperatures shown are approximates and may vary. IMPORTANT: Adjusting the thermostat past the 120°F bar on the temperature dial wilt increase the risk of scald injury. Hot water can produce first degree burns within: 110 116 116 122 131 140 149 154 (normal shower temp.
Vent System Inspection Carbon Monoxide and Fire Hazard , Fiue gases may escape if ,vent pipe is not connected, At least once a year, a visual inspection should be made of the main burner and pilot burner. See Figure 30. . Be alert for obstructed, sooted or deteriorated vent system to avoid serious injury or death.
Housekeeping Vacuum around base of water heater for dust, dirt, and lint on a regular basis. Fire and Explosion Hazard • Do not obstruct combustion air openings at the bottom of the water heater. • Do not use or store flammable vapor products such as gasoline, solvents or adhesives in the same room or area near water heater or other appliance.
operation. The water heater should be drained if being shut down during freezing temperatures. To drain the tank, perform the following steps: 1. Turn off the gas to the water heater at the manual gas shut-off valve. 2. Open a nearby hot water faucet until the water is no longer hot.
Replacement Parts IMPORTANT: The following maintenance procedures are for the FVIR System components and should be performed by a qualified technician. Replacement parts may be ordered from Sears Parts and Service Centers or by calling 1-800-4-MY-HOME (1-800-469- 4663).
as a bending template for the new pilot assembly. Note the placement/order ofthe wires in the manifold component block. Thermopile Connector _e Igniter j_- Wire i%' Mantfot! Component Block _ Pitot/Thermopite Assembly Screw B urneran other :_?_i_ fittings not show _;':_ for clarity.
Replacing the Manifold/Burner Assembly 10 Explosion Hazard Tighten both manifold door screws securely. Remove any fiberglass between gasket and combustion chamber. Replace viewport if glass is missing or damaged. Replace manifold component block if missing or removed.
Removing and Replacing the Gas Control Valve/Thermostat IMPORTANT: The gas control valve/thermostat is a standard valve with wire leads that connect to a thermal switch.
Start Up Conditions Thermal Expansion Property Damage Hazard • Avoid water heater damage. • Install thermal expansion tank or device if necessary. • Contact qualified installer or service agency. As water is heated, it expands (thermal expansion).
Condensation Whenever the water heater is filled with cold water, some condensate will form while the burner is on. Awater heater may appear to be leaking when in fact the water is condensation. This usually happens when: • A new water heater is filled with cold water for the first time.
appliance. Immediately call a qualified technician to inspect the appliance. Water heaters subjected to a flammable vapors ignition will require replacement of the entire water heater. 3. Reset the thermal switch by depressing the small button in the center of the thermal switch.
PROBLEM CORRECTIVE ACTION BURNER WILL NOT IGNITE POSSIBLE CAUSE(S) 1. Pilot not tit 2. Thermostat set too tow 3. Main burner line clogged 4. Non-functioning thermostat 5. Base-Ring Filter blocked with tint/dust 6. Heater installed in a confined area 7.
PROBLEM SLOW HOT WATER RECOVERY 1, 2. 3. 4. 5. 6. POSSIBLE CAUSE(S) insufficient combustion air Water heater flue or vent system blocked Low gas pressure Improper calibration Base-Ring Filter blocked with lint/dust CORRECTIVE ACTION 1. Provide ventilation to water heater.
LED STATUS 0 FLASHES (LED NOT LIT) RED LIGHT ON (SOLID) PROBLEM Pilot light is not lit or Thermopite has not yet reached normal operating temperature. Pilot light was recently extinguished and the Thermopile is cooling down. 1 FLASH (EVERY 3 SECONDS) Normal operation.
LED STATUS PROBLEM CORRECTIVE ACTION 4 FLASHES The Gas Control Valve's temperature sensor has detected that the water temperature was too high. Once this condition occurs, the Main Burner and the Pilot Light wilt be shut off.
Section A: Pilot light will not light (new installation). Is the manual gas shut-off valve, / klTurn the manual gas shut-off valve to I located in the supply line to the I_ NO _ the on position and follow the lighting I water heater, in the on position? 1 " l instructions on the front of the water heater.
KENMORE 12 YEAR GAS WATER HEATER 153.331140 153.331150 40 Gallon (Natural) 50 Gallon (Natural) /2_ i ¸_ f--._ Key No. Part Description 1 Anode Rod 2 Anode Rod (Secondary) 3 Base-Ring Filter 4 Burner .
43.
Your Home For troubleshooting, product manuals and expert advice: www.managemylife.com For repair - in your home - of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner's manuals that you need to do-it-yourself.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Kenmore 153.33115 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Kenmore 153.33115 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Kenmore 153.33115, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Kenmore 153.33115 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Kenmore 153.33115, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Kenmore 153.33115.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Kenmore 153.33115. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Kenmore 153.33115 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.