Manuel d'utilisation / d'entretien du produit 1030 du fabricant Keiser
Aller à la page of 14
Solenoid Valve Replacement for 1030/1031 Compressor INTRODUCTION KEISER CORPORATION has always taken pride in designing and engineering the highest quality equipment on the market. This means that you will receive years of low maintenance and minimal repairs from every one of our machines.
10-5508 Rev A Service Department (800) 888-7009 2 Solenoid Valve Replacement for 1030/1031 Compressor * WARNING: Unplug compressor before beginning. Before replacing valve, draw all of the air out of the compressor by pressing both the + and – buttons on the exercise equipment.
10-5508 Rev A Service Department (800) 888-7009 3 Step Two: Remove hoses After the screws have been removed, take the ½ inch open-ended wrench, and loosen the nut that connects the hose to the valve by turning it counter-clockwise, and remove the hose.
10-5508 Rev A Service Department (800) 888-7009 4 Next, remove the lid to the computer control system box by unscrewing the screw on either side. remove two screws on lid Then remove the rubber grommet by using the needle nose pliers to carefully pop it out of the hole.
10-5508 Rev A Service Department (800) 888-7009 5 1030 Circuit Board Diagrams Rev A, B, C Rev D - Current.
10-5508 Rev A Service Department (800) 888-7009 6 push on board, pull on wire Pull each of the four wires back out the hole one by one. Save the rubber grommet.
10-5508 Rev A Service Department (800) 888-7009 7 Step One: Adjust and mount new valve First, make sure that the valve is open. Try to turn the pet-cock on the valve counter- clockwise. If you cannot turn it further counter-clockwise, it is open. open valve counter-clockwise The new valve allows you to rotate its housing for easy mounting.
10-5508 Rev A Service Department (800) 888-7009 8 Next, remove the compression nut that connects the hose to the valve. Replace it with the original compression nut, attach the hose, and tighten the compression nut finger tight. Take the ½ inch wrench and rotate the nut ½ to ¾ turn.
10-5508 Rev A Service Department (800) 888-7009 9 Left side valve Right side valve Repeat the process under Step One to mount the second valve. Step Two: Install single to double adapter and electrical wires Take all four electrical wires and insert them, one by one, through the rubber grommet, and then through the hole.
10-5508 Rev A Service Department (800) 888-7009 10 Step Two: Install single to double adapter and electrical wires Take all four electrical wires and insert them, one by one, through the rubber grommet, and then through the hole. Pull all of the slack into the computer system control box.
10-5508 Rev A Service Department (800) 888-7009 11 Take the single to double adapter and turn it so that the two top prongs are pointing to the left hand side of the box. The bent portion with these two prongs should be over the fuse. Replace the connector with the single to double adapter in L1.
10-5508 Rev A Service Department (800) 888-7009 12 Step Three: Secure and tie wires and replace lid Make sure that all of the slack is inside the computer control system box. Use a zip tie to bind the wires and hoses on the outside of the box. Use the wire cutters to cut off the excess.
10-5508 Rev A Service Department (800) 888-7009 13 feel for air flow After the flow of air has stopped, wait thirty seconds. Slowly lower the air in the compressor to approximately 95 PSI and the compressor should start. Open the valve by turning the handle counter-clockwise to allow the air to reach the equipment.
10-5508 Rev A Service Department (800) 888-7009 14 2470 S. Cherry Ave. Fresno, CA 93706 1(800) 888-7009 Fax: (559 )256-8100 e-mail: info@keiser.com www.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Keiser 1030 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Keiser 1030 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Keiser 1030, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Keiser 1030 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Keiser 1030, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Keiser 1030.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Keiser 1030. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Keiser 1030 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.