Manuel d'utilisation / d'entretien du produit Fryer du fabricant Keating Of Chicago
Aller à la page of 52
1-800-K EA TI NG www .keatingofchicago.com Users Manual I N ST ANT R E CO VE R Y ® GAS FR YE R SERIES 2 0 0 9 R EAD AN D SA VE TH I S MAN U AL F OR FUTUR E R E FE R E NCE. Keep this manual for training new personnel. I M PORT ANT SAFETY I N STR UCTION S .
i W A RNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
INTRODUCTION Instructions in this manual should be read thor oughly before attempting to operate this Keating Gas Fryer . All installation and service on Keating equipment must be performed by qualified, certified, licensed and/or authorized installation or service personnel.
operation. Air for combustion enters the fryer from the bottom of the cabinet and the bottom of the control panel. DO NOT BLOCK BOTTOM OF KEA TING INST ANT RECOVER Y ® GAS FR YER CABINET . DO NOT OBSTRUCT FLUE. Y our Keating Instant Recovery ® Gas Fryer is designed to be serviced from the fr ont.
3 FLEXIBLE GAS CONNECTORS AND QUICK DISCONNECT DEVICES For an appliance equipped with casters: The installation shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or the Standard for Connectors for Moveable Gas Appliances, CAN/CGA-6.
4 FILLING NOTE: Before filling the fryer make certain the fryer vessel is sanitized, dry and the drain valve is completely closed. NOTE: Solid shortening can not be used in a Keating Model AA Gas Fryer . If solid shortening is used, it should be melted prior to filling the fryer vessel.
5 SERIES 2000 BB MODELS OPERA TING INSTRUCTIONS BB CONTROL P ANEL – SERIES 2000 ST AR T -UP PROCEDURE WARNING: DO NOT ST AR T FRYER WITHOUT FIRST FILLING FR Y POT . STEP 1. Set "MEL T -IDLE-FR Y" switch to "IDLE" position and thermostat to the "OFF" position.
6 SERIES 2000 TS MODELS OPERA TING INSTRUCTIONS TS CONTROL P ANEL – SERIES 2000 ST AR T -UP PROCEDURE WARNING: DO NOT ST AR T FRYER WITHOUT FIRST FILLING FR Y POT . STEP 1. Set "MEL T -IDLE-FR Y" switch to "IDLE" position and thermostat to the "OFF" position.
7 Select "MEL T" with solid shortening until liquid shortening is 1" from full mark then switch to the "FR Y" position after packing shortening around burner tubes. SHUTDOWN PROCEDURE STEP 1. Set thermostat to the "OFF" position.
OPERA TION OF THIS FR YER SHOULD BE LIMITED TO PERSONNEL WHO HA VE BEEN THOROUGHL Y TRAINED IN OPERA TING PROCEDURES. CARE SHOULD BE T AKEN WHEN LOWERING BASKETS INTO FR YER TO PREVENT SPLASHING HOT OIL FROM FR YER VESSEL. If your fryer has timers, push the “ T1, ” “ T2 ” or “ T3 ” button on the digital timer(s).
9 1. Operator should be outfitted with proper attir e including: •Oil and heat resistant gloves •Oil and heat resistant apr on •Safety goggles •Oil and heat resistant footwear 2. T urn off the fryer and open the door . 3. Put suitable container under drain valve.
SAFE & EASY FIL TER (SIDE VIEW) A KEA TING FR YER OR FIL TER SHOULD BE DRAINED ONL Y UNDER THE SUPERVISION OF PROPERL Y TRAINED PERSONNEL. WHEN DISCARDING OIL, A COVERED RECEPT ACLE APPROVED FOR USE WITH HOT OIL SHOULD BE USED. USE OF A NON-APPROVED RECEPT ACLE OR METHOD OF DRAINING THE OIL COULD JEOP ARDIZE THE SAFETY OF THE OPERA TOR.
11 OPERA TOR SELF HELP Before calling for service, r eview this list. It may save you both time and expense. This list includes common occurrences that ar e not the result of defective workmanship or materials in this appliance.
Thermostat Bulb Positioning 10×11, 18 & larger Fryer Gas DO NOT ADJUST THERMOST A T SET SCREW - IT VOIDS ANY WARRANTY ON P AR T W ARRANTY REP AIRS Keating's warranty begins with the date of installation.
13 PROBLEM PROBABLE CAUSE SOLUTION Constant pilot won’t light. a. Gas isn’t turned on. b. Clogged constant pilot tubing. c. Constant pilot valve isn’t turned on. a. T urn manual gas valve on. If using flexible connector with quick disconnect, make sure quick disconnect is completely engaged.
Burners will not light. a. Gas valve knob in incorrect position (AA & CMG models). b. Switch not set to fry (BB & TS models). c. Thermostat is faulty . d. Fry/Off/Melt switch (BB & TS models) or On/Off switch (AA & CMG models) is faulty .
TROUBLESHOOTING CHAR T (continued) Flames come out top of flue. a. Excessive gas supply or pressur e. b. Collapsed burner radiants. c. Exhaust problems. a. Adjust pressur e, change bur ner orifices or install in-line regulator . b. Replace radiants. c.
P AR TS LIST ORDERING P ARTS Parts may be order ed by part number by calling Keating at 1-800-KEA TING or your local service company . Y ou may also order online at Keating’ s part stor e, www .keatingofchicago.com. Refer to the limited warranty in this manual for complete service and ordering information.
17 GAS FR YER ASSEMBL Y T op & Side Views Front View Door Catch, Magnet (Series 2000 to 1 1/2001) T op & Side Views Front View Door Catch, Magnet (Series 2001 to current) Item # 22.
18 SERIES 2000 - 2005 RUNNER PILOT ASSEMBL Y (S park Ignition Models - See p age 27).
19 SERIES 2005-2009 RUNNER PILOT ASSEMBL Y (S park Ignition Models - See p age 27) 2 3 10 6 Locknut 6 7 8 14 3 6 10 Locknut 6 7 8 14 2 3 10 10 Locknut 6 7 8 14 12 12 14 8 7 6 Locknut 11 to Gas V alve .
CONTROL P ANEL AA & CM GAS – SERIES 2006 C T O 250 275 350 H R B I L A S E T A I D F I T L A 375 300 325 OFF ON POWER QTY . DESCRIPTION P/N A 1 THERMOST A T DIAL PLA TE 250º-375°F 058037 B 1 T.
J G H D A B, C CONTROL P ANEL BB GAS – SERIES 2000 Control Panel Fr ont Back Panel 21 QTY . DESCRIPTION P/N A 1 THERMOST A T DIAL PLA TE 250°-375ºF 058037 B 1 THERMOST A T KNOB 004163 C 1 GAS FRYE.
22 C T O 250 275 350 H R B I L A S E T A I D F I T L A 3 75 300 325 FRY OFF ON ON POWER POWER MEL T CONTROL P ANEL BB SP ARK IGNITION - SERIES 2006 Control Panel Fr ont Back Panel - Rear Drain Unit QTY .
23 CONTROL P ANEL TS GAS - SERIES 2000 QTY . DESCRIPTION P/N A 1 THERMOST A T DIAL PLA TE 250°F 058037 B 1 THERMOST A T KNOB 004163 C 1 GAS FRYER THERMOST A T 14 ” BB, TS, IFM, CPU 035574 10x11, 18.
QTY . DESCRIPTION P/N A 1 SWITCH TOGGLE POWER 059141 B 1 LIGHT INDICA TING ROUND - CLEAR 057863 C 1 SWITCH TOGGLE PILOT 059142 D 1 LIGHT INDICA TING ROUND - AMBER 056588 E 1 SWITCH TOGGLE MEL T - FRY .
25 CONTROL P ANEL TS SP ARK IGNITION - SERIES 2007 FOR 34 X 24 MODEL, SERIES 2009 FOR ALL OTHER MODELS QTY . DESCRIPTION P/N A 1 SWITCH TOGGLE POWER 059141 B 1 INDICA TING LIGHT CLEAR 057863 C 1 SWITC.
26 CPU CONTROL P ANEL SERIES 2007 CPU CONTROL P ANEL SERIES 2010 Control Panel Fr ont Control Panel Fr ont A B C D E Back Panel - Front Drain Unit Back Panel - Front Drain Unit I F G H J Back Panel - Rear Drain Unit Back Panel - Rear Drain Unit F J K O L M I N QTY .
Design V alid Appr ox. Sept. 2004 - Current QTY . DESCRIPTION P/N A 1 SP ARK IGNITION ELECTRODE 030253 B 1 RUNNER PILOT TUBE 10×11 021656 14 ” 028828 18 ” 021658 20 ” 021730 24 ” 037623 34×24 C* 1 SP ARK IGNITION MODULE 058439 *Not Shown A B 27 SP ARK IGNITION DESIGN V ARIA TIONS Design V alid Appr ox.
28 DESCRIPTION QTY P AR T # 1 TRANSFORMER 120/208/240/480V 1 056036 2 CIRCUIT BREAKER 3A/250V 1 053338 3 RELA Y DPDT 24V AC 2 030844 4 RECTIFIER 1 018321 5 POWER CORD 1 021289 6 CONNECTION 3 CIRCUITS .
29 DESCRIPTION QTY P AR T # 1 TRANSFORMER STEPDOWN 24VAC 100V A 1 058359 2 RELA Y DPDT 24V AC 2 030844 RELA Y DPDT 24V AC (CPU MODEL) 2 017673 3 RECTIFIER 24VDC 1 018321 4 BUSHING STRAIN RELIEF 5 / 8 .
30 ELECTRICAL BOX ASSEMBL Y GAS FR YER (TS and BB ONL Y) 2000 SERIES QTY . DESCRIPTION P/N A 1 TRANSFORMER 120V/240V TO 24V 024032 B 1 2 PIN CONNECTOR 032207 C 1 9 PIN CONNECTOR 028303 D 1 F A T MEL T.
31 CM & AA 2000 ELECTRICAL ASSEMBL Y FRONT DRAIN SEE INSIDE FR YER DOOR FOR CURRENT WIRING DIAGRAMS COMPONENT CODES: P – POWER SWITCH TH – THERMOSTAT HL – HIGH LIMIT AA 2007 ELECTRICAL ASSEM.
32 BB 2000 ELECTRICAL ASSEMBL Y AA 2010 ELECTRICAL ASSEMBL Y FRONT DRAIN.
33 BB 2006 ELECTRICAL ASSEMBL Y Electrical Assembly not shown to scale BB 2000 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER.
34 BB 2006 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER 34 X 24 BB 2007 ELECTRICAL ASSEMBL Y FRONT DRAIN.
35 34 X 24 BB 2008 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER 34 X 24 BB 2007 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER.
36 Electrical Assembly not shown to scale TS 2000 ELECTRICAL ASSEMBL Y BB 2006 SP ARK IGNITION WITH SAFE & EASY ® FIL TER.
37 TS 2007 ELECTRICAL ASSEMBL Y FRONT DRAIN TS 2000 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER.
38 TS 2007 ELECTRICAL ASSEMBL Y BASKET LIFT FRONT DRAIN TS 2007 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER.
39 TS 2007 ELECTRICAL ASSEMBL Y SP ARK IGNITION FRONT DRAIN TS 2009 ELECTRICAL ASSEMBL Y BASKET LIFT FRONT DRAIN.
40 TS 2007 ELECTRICAL ASSEMBL Y SP ARK IGNITION WITH SAFE & EASY ® FIL TER TS 2009 ELECTRICAL ASSEMBL Y BASKET LIFT FRONT DRAIN.
41 34 X 24 TS 2007 ELECTRICAL ASSEMBL Y FRONT DRAIN 34 X 24 TS 2007 ELECTRICAL ASSEMBL Y FRONT DRAIN.
42 34 X 24 TS 2007 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER 34 X 24 TS 2008 AND ALL TS MODELS 2009 ELECTRICAL ASSEMBL Y FRONT DRAIN.
43 34 X 24 TS 2007 AND ALL TS MODELS 2009 ELECTRICAL ASSEMBL Y SP ARK IGNITION WITH SAFE & EASY ® FIL TER 34 X 24 TS 2008 AND ALL TS MODELS 2009 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL T.
44 CPU 2007 ELECTRICAL ASSEMBL Y WITH SAFE & EASY ® FIL TER CPU 2007 ELECTRICAL ASSEMBL Y FRONT DRAIN.
45 CPU 2007 ELECTRICAL ASSEMBL Y SP ARK IGNITION WITH SAFE & EASY ® FIL TER CPU 2007 ELECTRICAL ASSEMBL Y SP ARK IGNITION FRONT DRAIN.
46 BASKET LIFT ELECTRICAL ASSEMBL Y NON-CPU MODELS SERIES 2007 BASKET LIFT ELECTRICAL ASSEMBL Y PRE 2007 (ALL FRYERS).
47 BASKET LIFT ELECTRICAL ASSEMBL Y WITH CPU MODELS SERIES 2007.
.
.
KEA TI N G LI M ITE D W AR RANTY C AR D PLEASE CO M PLETE AND MAI L A T O NCE–WARR ANTY IS N O T I N EF FECT U NTIL CAR D IS R ETU R NE D. W AR RANTY CAR D IS AL SO AV AI LABLE T O C OM PLETE ON LI NE A T YOU R CO NVEN I E NC E.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Keating Of Chicago Fryer c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Keating Of Chicago Fryer - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Keating Of Chicago Fryer, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Keating Of Chicago Fryer va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Keating Of Chicago Fryer, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Keating Of Chicago Fryer.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Keating Of Chicago Fryer. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Keating Of Chicago Fryer ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.