CONNECTION DIAGRAM 8-Lead Plastic Mini-DIP (N), Cerdip (Q) and SOIC (R) Packages –IN R G –V S +IN R G +V S OUTPUT REF 1 2 3 4 8 7 6 5 AD620 TOP VIEW REV.
AD620–SPECIFICA TIONS (Typical @ +25 8 C, V S = 6 15 V, and R L = 2 k V , unless otherwise noted) AD620A AD620B AD620S 1 Model Conditions Min Typ Max Min Typ Max Min Typ Max Units GAIN G = 1 + (49.4 k/R G ) Gain Range 1 10,000 1 10,000 1 10,000 Gain Error 2 V OUT = ± 10 V G = 1 0.
AD620 AD620A AD620B AD620S 1 Model Conditions Min Typ Max Min Typ Max Min Typ Max Units DYNAMIC RESPONSE Small Signal –3 dB Bandwidth G = 1 1000 1000 1000 kHz G = 10 800 800 800 kHz G = 100 120 120 120 kHz G = 1000 12 12 12 kHz Slew Rate 0.75 1.2 0.
AD620 REV. E –4– NOTES 1 Stresses above those listed under Absolute Maximum Ratings may cause perma- nent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied.
AD620 REV. E –5– T ypical Characteristics (@ +25 8 C, V S = 6 15 V, R L = 2 k V , unless otherwise noted) INPUT OFFSET VOLTAGE – m V 20 30 40 50 –40 0 +40 +80 PERCENTAGE OF UNITS –80 SAMPLE SIZE = 360 10 0 Figure 3.
AD620–T ypical Characteristics FREQUENCY – Hz 1000 100 10 1 10 1000 100 CURRENT NOISE – fA/ ! Hz Figure 9. Current Noise Spectral Density vs. Frequency RTI NOISE – 2.0 m V/DIV TIME – 1 SEC/DIV Figure 10a. 0.1 Hz to 10 Hz RTI Voltage Noise (G = 1) RTI NOISE – 0.
AD620 REV. E –7– FREQUENCY – Hz PSR – dB 160 1M 80 40 1 60 0.1 140 100 120 100k 10k 1k 100 10 20 G = 1000 G = 100 G = 10 G = 1 180 Figure 14. Positive PSR vs. Frequency, RTI (G = 1–1000) FREQUENCY – Hz PSR – dB 160 1M 80 40 1 60 0.1 140 100 120 100k 10k 1k 100 10 20 180 G = 10 G = 100 G = 1 G = 1000 Figure 15.
AD620 REV. E –8– OUTPUT VOLTAGE SWING – Volts p-p LOAD RESISTANCE – V 30 0 0 10k 20 10 100 1k V S = 6 15V G = 10 Figure 20. Output Voltage Swing vs. Load Resistance .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... ...
AD620 REV. E –9– .... .... .... .... .... .... .... .... ........ .... .... .... .... .... .... .... .... ........ Figure 26. Small Signal Pulse Response, G = 100, R L = 2 k Ω , C L = 100 pF .... .... .... .... .... .... .... .... .... .... ....
AD620 REV. E –10– V B –V S A1 A2 A3 C2 R G R1 R2 GAIN SENSE GAIN SENSE R3 400 V 10k V 10k V I2 I1 10k V REF 10k V +IN – IN 20 m A 20 m A R4 400 V OUTPUT C1 Q2 Q1 Figure 33. Simplified Schematic of AD620 THEORY OF OPERATION The AD620 is a monolithic instrumentation amplifier based on a modification of the classic three op amp approach.
AD620 REV. E –11– Make vs. Buy: A Typical Bridge Application Error Budget The AD620 offers improved performance over “homebrew” three op amp IA designs, along with smaller size, fewer compo- nents and 10 × lower supply current.
AD620 REV. E –12– 3k V +5V DIGITAL DATA OUTPUT ADC REF IN AGND 20k V 10k V 20k V AD620B G=100 1.7mA 0.10mA 0.6mA MAX 499 V 3k V 3k V 3k V 2 1 8 3 7 6 5 4 1.
AD620 REV. E –13– Precision V-I Converter Th e AD620, along with an other op amp and tw o resistors, makes a precision current source (Figure 37). The op amp buffers the reference terminal to maintain good CMR. The output voltage V X of the AD620 appears across R1, which converts it to a curre nt.
AD620 REV. E –14– COMMON-MODE REJECTION Instrumentation amplifiers like the AD620 offer high CMR, which is a measure of the change in output voltage when both inputs are changed by equal amounts. These specifications are usually given for a full-range input voltage change and a speci- fied source imbalance.
AD620 REV. E –15– GROUND RETURNS FOR INPUT BIAS CURRENTS Input bias currents are those currents necessary to bias the input transistors of an amplifier.
AD620 REV. E –16– OUTLINE DIMENSIONS Dimensions shown in inches and (mm). Plastic DIP (N-8) Package 8 14 5 0.430 (10.92) 0.348 (8.84) 0.280 (7.11) 0.240 (6.10) PIN 1 SEATING PLANE 0.022 (0.558) 0.014 (0.356) 0.060 (1.52) 0.015 (0.38) 0.210 (5.33) MAX 0.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Analog Devices AD620 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Analog Devices AD620 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Analog Devices AD620, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Analog Devices AD620 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Analog Devices AD620, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Analog Devices AD620.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Analog Devices AD620. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Analog Devices AD620 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.