instruction manual AXlink Bus Controllers AXB-IRS4 IR/Serial Interface (4 P orts).
AMX Limited W arranty and Disc laimer AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Co.
T able of Contents i AXB-IRS4 IR/Serial Interface (4 P o rts) T able of Contents Product Information ........ ................ ................. ................ .............. .............. ............ 1 Specifications .............................
ii AXB-IRS4 IR/Serial Interface (4 Ports) T able of Contents.
Product Information 1 AXB-IRS4 IR/Serial Interface (4 P o rts) Pr oduct Inf ormation The AXB-IRS4 (FIG. 1) is an AXCESS bus de vice you can program to cont rol up to four infrared (IR) or serial-controlled audiovisual de vices such as televis i ons and video cassette recorders.
Product Information 2 AXB-IRS4 IR/Serial Interface (4 Ports) AXB-IRS4 Specificati ons (Cont.) PWR co nnector 2-pin captive wire connector connec ts an external 12 VDC power supply to the AXB-IRS4.
Configuration and Installation 3 AXB-IRS4 IR/Serial Interface (4 P o rts) Configuration and Installation Setting the Device DIP Swi t ch The 8-position DEVICE DIP sw itch sets the AXlink identification number for the AXB-CAM. Make sure the de vice number matches the numb er assigned in the AXCESS software program.
Configuration and Install ation 4 AXB-IRS4 IR/Serial Interface (4 Ports) P ositions 1-4: Carrie r signal enable/disab le DIP Swit ch positio ns 1-4 on the CARRIER/B A UD DIP switch determine wether the AXB-IRS4 transmits carrier signals along with the IR equipment codes .
Configuration and Installation 5 AXB-IRS4 IR/Serial Interface (4 P o rts) Setting the Internal J umpers (E1 and E2) f or AXlink or RS-232 Comm unication Internal jumpers are located on th e circuit card inside the AXB-IRS 4 enclosure. Y ou will need a Phillips-head scre wdriver to open the enclosure.
Configuration and Install ation 6 AXB-IRS4 IR/Serial Interface (4 Ports) Wiring the AXB-IRS4 The serial, IR, AXlink, and power supply connectors are located on the rear panel of the AXB-IRS4 as sho w n in FIG. 5. The AXlink connector can also be used for RS-232 communications.
Configuration and Installation 7 AXB-IRS4 IR/Serial Interface (4 P o rts) Using AXlink for data and powe r Connect the Central Controller's AXlin k connector to the AXlink/RS-232 connector , on the rear panel of the AXB-IRS4, for data and 12 VDC power , as shown in FIG.
Configuration and Install ation 8 AXB-IRS4 IR/Serial Interface (4 Ports) FIG. 8 shows the AXlink/RS-232, DB-9, and power supply wiring diagram. For some applications, you may need to strap pins 7 (request to send) and 8 (clear to send) together dependin g on the PC (as shown in the illustration).
Configuration and Installation 9 AXB-IRS4 IR/Serial Interface (4 P o rts) Connecting an IR de vice IR devices connect to the AXB-IRS4 with an IR device cable. The cables supplied with the AXB- IRS4 are designed to accommodate the IR de vi ces in your system.
Configuration and Install ation 10 AXB-IRS4 IR/Serial Interface (4 Ports) Contact your AMX dealer before y ou replace the lithium battery and verify that the y have a current copy of the AXCESS pro gram for your AXB-IRS4. This will av oid any inadvertent loss of data or a service outage.
Programming 11 AXB-IRS4 IR/Serial Interface (4 P o rts) Pr ogramming Channel Setting Commands The AXB-IRS4 channel settings listed in th e following table set IR output channels. The AXB- IRS4 can process up to two IR or serial de vice chann el setting commands simultaneously .
Programming 12 AXB-IRS4 IR/Serial Interface (4 Ports) Send Com mands (C ont.) Command Description 'CH',channel number T ransmit the IR pulses that select the proper chan nel. Enter all channel numbers below 100 as two digits . For ex ample, enter channel 1 as 01.
Programming 13 AXB-IRS4 IR/Serial Interface (4 P o rts) Send Com mands (C ont.) Command Description "'SP',code" T ransmit IR code pulses. Pulse time is set by the CT ON and CTOF com- mands. Va r i a b l e : code = 1-252 Example: SEND_COMMAND 1,"'SP',2" T ransmits a pulse out for command n umber 2 to device 1.
Programming 14 AXB-IRS4 IR/Serial Interface (4 Ports) RS-232 Pr otocol Commands The RS-232 protocol commands listed in the follow ing tables send control signals from an RS-2 32 device to the AXB-IRS4. The follo wing RS-23 2 figur es are grouped together by IR output, channel pulse time, and carrier commands.
Programming 15 AXB-IRS4 IR/Serial Interface (4 P o rts) RS-232 Pr otocol Commands (Channel Pulse Time) RS-232 Pr otocol Commands (Carrier) RS-232 Pr otocol Commands (IR Output - Cont.) Command Description ON[Dev ,Chan] Star t IR outpu t on the designated device and channel.
Programming 16 AXB-IRS4 IR/Serial Interface (4 Ports) RS-232 Pr otocol Commands (Miscellaneou s) RS-232 Pr otocol Commands (Miscellaneou s ) Command Description ECHO OFF Disable the terminal ch aracter's echo function. ECHO ON Enable the terminal character's echo function.
Programming 17 AXB-IRS4 IR/Serial Interface (4 P o rts).
AMX reserves the right to alter specif ications with out no tice at a ny time . brussels • dallas • los ang eles • mexico city • philad elphia • shanghai • singapor e • tampa • toronto * • yo rk 3000 research drive, richardson, TX 75082 USA • 469.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté AMX Interface Port AXB-IRS4 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du AMX Interface Port AXB-IRS4 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation AMX Interface Port AXB-IRS4, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le AMX Interface Port AXB-IRS4 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le AMX Interface Port AXB-IRS4, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du AMX Interface Port AXB-IRS4.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le AMX Interface Port AXB-IRS4. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei AMX Interface Port AXB-IRS4 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.