instruction manual AXlink Bus Controllers AXB-232++ RS-232/422/485 Interface.
.
T able of Contents i AXB-232++ RS-232/422/485 Interface T able of Contents Product Information ........ ................ ................. ................ .............. .............. ............ 1 Front Panel ......................................
ii AXB-232++ RS-232/422/485 Interface T able of Contents.
Product Information 1 AXB-232++ RS-232/422/485 Interface Pr oduct Inf ormation The AXB-232++ RS-232/422/ 485 Interface is an AXlink b us cont roller that provides remote control for de vices that require a variety of control protocols. The AXB-232++ extends RS-232, RS-422, or RS-485 control to remot e sources over the 4-wire AXlink data/power bus.
Product Information 2 AXB-232++ RS-232/422/485 Interface Specifications The follo wing table lists the sp ecif ications for the AXB-232++. Specifications P ow er 12 VDC @ 160 mA Processor On board 32-bit proc essor and 384K (of non-volatile memor y) run Axcess programs independent of the control system.
Installation and Wiring 3 AXB-232++ RS-232/422/485 Interface Installation and Wiring The AXB-232++ can be used as an independent RS-232/422/485 -controlled in terface by setting the internal jumpers. C onfigure the communication pa rameters usin g the DIP switches on the front panel.
Installation and Wiring 4 AXB-232++ RS-232/422/485 Interface Setting jumper JP5 to set the RS-422 port for RS-48 5 use 1. Disconnect the RS-232/ 422/485 connectors. 2. Unscre w the two scre ws on the rear panel, and remove the panel. 3. Slide the circuit board out of the enclosure.
Installation and Wiring 5 AXB-232++ RS-232/422/485 Interface Setting the RS-232/42 2 DIP switc h Set the stop bits, data bits, parit y , and baud rate on the RS-2 32/422 DIP switch, located on the front panel (see FIG.
Installation and Wiring 6 AXB-232++ RS-232/422/485 Interface Wiring De vices to the AXB-232++ Preparing cap tive wires T o connect the wiring into a captiv e-wire connector: 1. Strip 1/4 inch off the wire insulation for all four wires. 2. T in 2/3 of the exposed wire.
Installation and Wiring 7 AXB-232++ RS-232/422/485 Interface Using RS-232 When communicating via RS -232, connect t he wiring as sh o wn in FIG. 6. Using Hard ware Handshaking When the controlled device requires hardw are handshaking, connect the wiri ng as sho wn in FIG.
Installation and Wiring 8 AXB-232++ RS-232/422/485 Interface Rack- mounting the AXB-232++ (optional) T o rack-mount the AXB-23 2++ into the optional A C-RK Accessory Rack Kit: 1. Remov e any connected po wer, and AXlink a nd RS-232 connectors from the rear panel.
Programming 9 AXB-232++ RS-232/422/485 Interface Pr ogramming Send_Commands The AXB-232++ supports t he same command set as the AXC-232. The following table lists the AXB-232++ Send_Commands. AXB-232++ Send_Commands B9MOFF Sets data bit mode to normal with DIP switch settings (default).
Programming 10 AXB-232++ RS-232/422/485 Interface AXB-232++ Send_Commands (Cont.) CHARD Sets delay betw een all transmitted characters to the increment specified. Syntax: 'CHARD-<time>' Va r i a b l e : time = 100 microsecond increments 0 - 255.
Programming 11 AXB-232++ RS-232/422/485 Interface Axcess pr ogram c haracteris tics The AXB-232++ is capable of running Axcess prog rams. It handles string processing, relieving AXlink and the Master of the processing times. AXB-232++ Send_Commands ( Cont.
Programming 12 AXB-232++ RS-232/422/485 Interface Send_String Escape Sequences The AXB-232++ does not regard certain three-character combin ations wi thin a Send_Strin g program as literal characters, b ut as commands . The following table lists those combinations.
Programming 13 AXB-232++ RS-232/422/485 Interface AXB-232++ Pr ogram Statements The Axcess program of the AXB-2 32++ communicates with the ma ster as De vice 0. Its de vice communicates with the RS232/422 Input/Outpu t (I/O) of the AXB-232++ as Device 1.
Programming 14 AXB-232++ RS-232/422/485 Interface Xmodem Timing Commands The following table lists the AXB-232++ Xmodem timing commands. Xmodem timeouts exist to accommodate potential Ethernet delays and for consistency among and within products.
Programming 15 AXB-232++ RS-232/422/485 Interface Reserved Channels The follo wing table lists the channels reserv ed on Device 0. Axcess Master Mode When an Axcess device is placed in "Master Mode", the Central Controller’ s PR OGRAM port is moved to the Axcess de vice’ s RS-232 por t.
AMX reserves the right to alter specif ications without notice at any time. 032-004-171 8 9/05 © 2005 AMX Corporation. All rights reserved. AMX, the AMX logo, th e building icon , the home icon, and th e light bulb icon are a ll trademarks of AMX Corporatio n.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté AMX AXB-232++ c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du AMX AXB-232++ - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation AMX AXB-232++, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le AMX AXB-232++ va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le AMX AXB-232++, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du AMX AXB-232++.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le AMX AXB-232++. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei AMX AXB-232++ ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.