Manuel d'utilisation / d'entretien du produit Anterus du fabricant AMX
Aller à la page of 38
Operation/Reference Guide Control System Accessories Anterus ™ RFID Solution ANT-RDR Reader ANT-BDG Badge ANT-TAG Device/Asset Tag Last Updated: 10/22/200 8.
AMX Limited Warranty and Disclaimer This Limited W arranty and Disclaimer extends only to products purchased directly from AMX or an AMX Authorized Partn er which include AMX Dealers, Distributors, VIP’s or other AMX authorized entity .
Table of Contents i Anterus RFID Solution Table of Contents Anterus™ RFID Solution ........... .......................................................................... 1 Overview .............................. ......................... ...........
ii Anterus RFID Solution Table of Contents Anterus Configuration Manager ......... ............................................... ............... 15 Overview ........... .................... ......................... ................... .............
Anterus™ RFID Solution 1 Anterus RFID Solution Anterus ™ RFID Solution Overview The Anterus™ RFID Solution provides a Radio Fr equency IDentification (RFID) solution from AMX that extends the capabilities of the integrated A/V or control system.
Anterus™ RFID Solution 2 Anterus RFID Solution ANT-RDR RFID Reader The ANT -RDR (FG5172) connects to the NetLinx controller to initiate system events whene ver an ANT - T A G D evice/Asset tag, or ANT -BDG ID badge passes into its zone (FIG.
Anterus™ RFID Solution 3 Anterus RFID Solution ANT-RDR Prod uct Specific ations The following table pro vides product specifications for the ANT -RDR Reader: ANT-RDR Mounting/Installation The ANT -RDR can be DIN-Rail mo unted using the (optional) AC-DIN-EXTR DIN Rail Mounting Bracket (FG532-05).
Anterus™ RFID Solution 4 Anterus RFID Solution Anterus RFID Tags The two types of RFID T ags ( ANT -T A G , and ANT -BDG ) a re described in the following subsections: RFID Tags - Internal Battery An internal lithium battery powers the Anterus RFID T ags.
Anterus™ RFID Solution 5 Anterus RFID Solution ANT-TAG Device/Asset Tag The ANT -T A G Device/Asset T ag (FG5172-01) attaches to devices to identify and track loca tion, and trigger system e vents (FIG. 4). . Attach the ANT -T A G to a stationary or mobile asset to monitor the location of the asset.
Anterus™ RFID Solution 6 Anterus RFID Solution ANT-TAG Moun ting/Installation ANT -T A G T ags can be mounted on a variety of non-metallic items. Where permanent f ixing is required, VHB double-sided tape is used ( L-T A400 ).
Anterus™ RFID Solution 7 Anterus RFID Solution ANT-BDG Product Spec ifications ANT-BDG Mounting/Installation ANT -BDG T ags can be mounted on a variety of ite ms. Where permanent fixing is required VHB double- sided tape is used (Product number L-T A200); otherwis e, the tags may be worn on a necklace or clipped to clothing.
Anterus™ RFID Solution 8 Anterus RFID Solution Signal Strength Behavior of AMX RFID Tags and Readers The AMX RFID system tracks assets and personnel by measuring the strength of the RF signal rec ei ved from a periodically transmitting badge or tag.
Anterus™ RFID Solution 9 Anterus RFID Solution People and Objects When radio signals pass through materials other than air their strength is typically reduced more than passing through the same distance in air . The amount of additional decrease depends on the type of material.
Anterus™ RFID Solution 10 Anterus RFID Solution Conclusions T wo basic conclusions can be ma de from examining FIG. 9: First, a very strong signal implies the person or object is very close to the reader . This is simply due to the fact that it is impossible to recei ve a strong signal from far aw ay .
Installation 11 Anterus RFID Solution Installation Overview Installation and configuration of the Anterus solution includes connecting the ANT -RDR Reader to the NetLinx Master via AxLink, and using the ANT -RDR’ s built-in web interface to name each RFID tag, and specify communications and security settings.
Installation 12 Anterus RFID Solution Wiring Guidelin es The interface requires a 12 VDC power to operate properly . The interface uses a PSN2.8 po wer supply . The Central Controller supplies power via the AXlink cable or external 12 VDC power supply .
Installation 13 Anterus RFID Solution T o calculate the AXlink wiring distance formula for data an d power: 1. <T otal current consumption of all device's on AXlink cable> *<wire resistance per foot> * 2 = <voltage drop per foot>.
Installation 14 Anterus RFID Solution.
Anterus Configuration Manager 15 Anterus RFID Solution Anterus Configuration Manager Overview The Anterus Duet Module interfaces ANT -RDR Readers with NetLinx controllers, and adds the Anterus Configuration Manager to the NetLinx Master’ s built-in web console.
Anterus Configuration Manager 16 Anterus RFID Solution 4. Click the System button to access the Manage System page. The initial view is of the Manage System tab (FIG. 15). 5. Open the Manage De vices tab (FIG. 16). FIG. 15 Manage System page - Manage System tab FIG.
Anterus Configuration Manager 17 Anterus RFID Solution 6. Under Device Configur ation P ages , click on RF ID , then select AMX Anterus (FIG. 17). This opens the RFID Conf iguration Manager (Main page).
Anterus Configuration Manager 18 Anterus RFID Solution This page provides basic information on the entire Anterus System (in the Global Settings ro w), as well as for each ANT -RDR connected to the NetLinx Master: RFID Configuration Manager •N a m e Displays the Name assigned to each ANT -RDR.
Anterus Configuration Manager 19 Anterus RFID Solution Global Register Page Click the Conf igure icon in the Global Settings ro w (at the top of the RFID Conf igurati on Mana ger page - see FIG.
Anterus Configuration Manager 20 Anterus RFID Solution Global Reader Con figuration Optio ns The top section of the Global Re gister page contains ANT -RDR configuration options (FIG. 20): These options apply to ALL ANT -RDR Readers in the system.
Anterus Configuration Manager 21 Anterus RFID Solution Adding a Tag to the System 1. Click the Add T ag b utton in the bottom-left corner of the Global Re gister page (FIG. 21) to add a ne w RFID T ag to the system. This in vokes a set of fields for the ne w T ag at the bottom of the page (FIG.
Anterus Configuration Manager 22 Anterus RFID Solution Anterus Tags Configuration Opt ions The lower section of the Global Re gister page contains T ag configuration options. There is a separate entry for each T ag in the Anterus system (FIG. 20): FIG.
Anterus Configuration Manager 23 Anterus RFID Solution Viewing Tag Details Click on the Details icon for an y T ag to in vok e a popup windo w containing details for that T ag (FIG. 24): The T ag Details popup displays various data about the selected T ag.
Anterus Configuration Manager 24 Anterus RFID Solution Reader Configuration Pages Click the Configur e icon for any Reader in the RFID Configuration Manag er page - see FIG. 18 on page 17) to access the Reader Configuration page sho wn in FIG. 25: FIG.
Anterus Configuration Manager 25 Anterus RFID Solution Reader Configu ration Opti ons The top section of this page provides configura tion options for the selected A NT -RDR: FIG.
Anterus Configuration Manager 26 Anterus RFID Solution The lower section of this page provides conf igu ration options for each T ag assigned to this Reader: Tag Configuration Options (R eader Configuration Page) • T a g ID: Indicates the T ag ID assigned to each T ag ( display-only).
Programming 27 Anterus RF ID Solutio n Programming Anterus Duet Module - Overview The COMM module transla tes between the stand ard in terface described belo w and the device protocol. It parses the buf fer for responses from the device, sends strings to control the de vice, and receives commands from the UI module or telnet sessions.
Programming 28 Anterus RFID Solution DEFINE_EVENT DATA_EVENT[vdvAnterus] { ONLINE: { SEND_COMMAND vdvAnterus,'PROPERTY-Identifiers,97;98;99' SEND_COMMAND vdvAnterus,'REINIT' } } Port Mapping This module uses a si ngle virtual de vice: Channels The channels supported by the COMM module are listed be lo w .
Programming 29 Anterus RF ID Solutio n Send Commands (Cont.) ?AP Auto Poll T ime The T ags actively transmit, and the Reader picks them up and stores them into an event cue.
Programming 30 Anterus RFID Solution AXLink Channels Whenev er communications with a Master is established, the Master assu mes the ANT -RDR is at the default channel status.
Programming 31 Anterus RF ID Solutio n AXLink Levels Lev els are a means of applying a v alue to a physical element on the de vice. The ANT -RDR supports 8-bit le vels only with v alues from 0-255 to represent RSSI v alues. When a de vice comes ONLINE, the Master assumes the de vice is at the default le vel sta tus with all lev els set to 0.
Programming 32 Anterus RFID Solution.
Programming 33 Anterus RFID Solution.
10/08 © 2008 AM X. All rights reserved. AMX and the AMX logo are regist ered trademarks of AMX. AMX reserves the right to alter specifications without noti ce at any time. It’s Your World - Take Con trol™ 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA • 800.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté AMX Anterus c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du AMX Anterus - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation AMX Anterus, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le AMX Anterus va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le AMX Anterus, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du AMX Anterus.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le AMX Anterus. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei AMX Anterus ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.