IMPORTANT GENERAL SAFETY INFORMATION - ADDITIONAL SPECIFIC SAFETY ALERTS APPEAR IN THE FOLLOWING INSTRUCTIONS. DO NOT LIFT OR CARRY WATER HEATER BY THE TOP COVER. WATER HEATER DAMAGE OR PERSONAL INJURY MAY OCCUR IF THE COVER BECOMES DETACHED. READ CAREFULLY THE PRODUCT INSTALLATION, OPERATING AND MAINTENANCE MANUAL.
❑ THIS PRODUCT MUST BE INSTALLED AND MAINTAINED BY A LICENSED PROFESSIONAL PLUMBER, ELECTRICIAN, AS APPLICABLE. IN ADDITION TO THE INSTRUCTIONS IN THIS MANUAL, FOLLOW ALL APPLICABLE LOCAL AND STATE CODES INCLUDING MA CMR 248 OR IN THE ABSENCE OF SUCH CODES, THE CURRENT EDITIONS OF THE NATIONAL PLUMBING CODE AND THE NATIONAL ELECTRIC CODE.
-3- If a steel hydropneumatic tank is in place, replace it with a properly sized diaphragm expansion tank. Otherwise, significant heat transfer problems can occur by causing air to be trapped in the heat exchanger.
-4- 4. HYDROMAX ™ Plumbing DOMESTIC WATER PIPING 1. Connect the cold water supply to the pipe labeled COLD WATER. 2. Connect the HOT WATER piping to the domestic hot water system. 3. When all domestic water piping is complete, open the cold water supply and allow some water to enter the tank.
5. Ener-G-NET ™ Wiring -5- Ener-G-NET incorporates all of the temperature sensing and control necessary for HYDROMAX™ operation. Built-in switching relays may be wired to operate the boiler control and circulator pump or zone valve. The diagram below illustrates these internal switching functions.
-6- Ener-G-NET ™ Wiring Common wiring diagrams are shown below. Select the appropriate diagram for the application. Diagrams are popular examples only.
6. Ener-G-NET ™ Control Setup & Adjustment -7- Ener-G-NET features two distinct programming areas: User Modes and Installer Settings . User Modes consist of three end-user functional modes, while Installer Settings are primarily accessed upon initial setup to specify critical operating parameters.
-8- 7. Mechanical Aquastat Wiring Diagrams Common wiring diagrams are shown below. Select the appropriate diagram for the application. Diagrams are popular examples only. If your application is not shown, contact Amtrol Technical Support at 401.535.1216.
-9- PROBLEM POSSIBLE CAUSES SOLUTION No hot water 1. No power to unit 2. Circulator air-bound 3. Faulty circulator or zone valve 4. Faulty control 5. Boiler inoperable 1. Check circuit breaker, boiler emergency switch and boiler reset switch. 2. Purge air.
SCALDING HAZARD . If the water temperature is over 120°F, household members can suffer serious or fatal scalding and painful and permanent injury.
Description ID HM-41 Models HM-80 Models Heat Exchanger Replacement Kit 1 2713R002 2712R002 T op Cover Half (2 Required) 2 2704R512 2704R512 Mounting Panel, Digital Control 3 2704R525 2704R525 Mountin.
9040-694 (10/11) HYDROMAX, Ener-G-NET , AMTROL, AMTROL logo, Therm-X-T rol, and EXTROL are registered trademarks of AMTROLInc.andafliatesintheU.S.andelsewhere. Allrightsreserved. 1400 Division Road, West W arwick, RI 02893 T : 401.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Amtrol HM-80Z c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Amtrol HM-80Z - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Amtrol HM-80Z, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Amtrol HM-80Z va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Amtrol HM-80Z, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Amtrol HM-80Z.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Amtrol HM-80Z. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Amtrol HM-80Z ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.