Manuel d'utilisation / d'entretien du produit BY82000 du fabricant Jacuzzi
Aller à la page of 26
SUMMER RAIN ™ II 2 PERSON SHOWER SYSTEM ONE W ALL INST ALLA TION AND OPERA TING INSTRUCTIONS Jacuzzi Whirlpool Bath © BY82000 03/05.
Note: This is a professional grade product. A knowledge of construction techniques, plumbing and electrical installation according to codes are required for proper installation and user satisfaction. We recommend that a licensed contractor perform the installation of all Jacuzzi Whirlpool Bath © products.
CONTENTS Specifications _________________________________________________________________________ 2 Enclosure Specifications ________________________________________________________________ 3 Rough-in.
Important: Read complete instructions before beginning installation. Each unit arrives ready for installation, equipped with base, glass and associated hardware. Remove the unit from the carton. Retain the shipping carton until satisfactory inspection of the product has been made.
ROUGH-IN REFERENCE ENCLOSURE SPECIFICATIONS 48" 27-1 1/16" TOP VIEW 72" 38-15/16" 36" 1" TILE FLANGE BLOWER MOTOR FOR UNITS WITH AIR AIR LINE FOR UNITS WITH AIR 84" .
COMPONENT IDENTIFICA TION FRONT VIEW SIDE VIEW GLASS SIDE P ANEL GLASS DOORS RAIL BRACKET AND COVER CAP SIDE SUPPORT RAIL CENTER SUPPORT RAIL AIR TOWER W A TER TOWER SEA T BASE DOOR POST DOOR POST W A.
PRELIMINARY ROUGH-IN The floor structure beneath the unit must be able to support a total weight of the unit and bather. Refer to page 2, SPECIFICATIONS, for weight specifica- tions . Refer to COMPONENT IDENTIFICATION on page 4 to help identify parts.
STEP 6 With a large screwdriver and the tool included with the drain, tighten the inside compression nut to seal the drain pipe connection. After drain is fully installed, test for proper drainage. If the shower base does not drain properly, rectify this condition before proceeding with the installation.
STEP 7 Place cement board or equivalent on top of shower base flange and secure to studwall. Apply tile (or other finishing material) leaving a 1/8" gap between the finishing material and the shower base flange lip. Seal this gap with silicone sealant.
T OWERS AND DOORS INST ALLA TION THESE INSTRUCTIONS ARE FOR SUMMER RAIN UNITS WITH AND WITHOUT AIR FEATURE OPTION. REFER TO COMPONENT IDENTIFICATION ON PAGE 4 TO HELP IDENTIFY PARTS. All wall finish tiling, trim, and sealing should be completed before beginning this part of the installa- tion.
TOWERS AND DOORS INST ALLA TION STEP 4 Take the side support rails and install a cover cap and wall bracket on each end. Place the center support rail into slot on each tower. If rail does not readily fit into slots, it may be necessary to loosen the bolts holding towers to base (it may only be necessary to loosen one tower).
TOWERS AND DOORS INST ALLA TION STEP 5 Two shut-off valves are provided per water tower. To hook up supply lines, unscrew valves from braided line. Using thread sealant, screw each valve to stub out at bottom of tower. Then reconnect braided line using provided gasket.
TOWERS AND DOORS INST ALLA TION STEP 6 Move the door assembly to the door post on water tower and slide the assembly into the door post. Locate the base of the door into the slot of serrated door positioner that positions the hinge barrel as shown.
TOWERS AND DOORS INST ALLA TION FINISH W ALL EDGE OF BASE GLASS SIDE PANEL MOUNTED PARALLEL TO EDGE OF BASE W ALL POST T APE (3) SCREWS (3) STEP 9 Position the fixed glass wall post so that the glass side panel will be parallel with the outside edge of the base.
TOWER AND DOOR INST ALLA TION STEP 12 Align the glass with glass jamb and insert. Repeat STEPS 8 through STEP 10 for the other fixed glass panel. W ALL POST GLASS GLAZING GASKET INSIDE OF ENCLOSURE AP.
STEP 16 Install handles as shown. Note orientation of handle. Hand tighten knob. Flat screw has a screw driver notch. Do not over tighten either knob or flat screw as cracked glass may result.
TOWERS AND DOOR INST ALLA TION APPL Y SEALANT ALONG BASE AND SIDE OF W ALL POST AND GLASS AND W ALL POST (BOTH SIDES) APPL Y SEALANT ALONG BASE OF FIXED GLASS (BOTH SIDES) APPL Y SEALANT ALONG SIDE OF.
OPERA TION SHOWER T OWERS 16 Jacuzzi Whirlpool Bath © BY82000 03/05 Shower Head There are three selectable positions: Jet, Normal Pul- sating, and Aerated flow. Body Sprays (2 Upper and 2 Lower) To adjust the flow and intensity, turn as shown. The spray can also be turned to change the direction of the spray.
OPERA TION CONTROLLER To turn ON press ON/OFF button or turn ON water at either shower tower. The unit will then automatically go into a preheat cycle to heat the air transmission pipes. There will be a 5 (five) minute pause while the system preheats.
To remove any lime scale from the shower head and body sprays, rub with your finger the outer ring of nozzles on the shower head and all nozzles on the body spray. To clean the foot temperature tester, unscrew the nozzle and back flush the wire mesh filter.
T OWER FIXTURES REP AIR P ARTS 19 Jacuzzi Whirlpool Bath © BY82000 03/05 TOWER ASSEMBLY WASHER (PART OF D709827) 4 6 9 (5X) 10 11 (4X) 13 14 15 16 17 18 19 3 (5X) 2 (5X) 1 (5X) 8 5 12 PART OF D709827 7 (PART OF U547000) 1. C546000 Lock Nut, 1/2" NPT WP (5X) 2.
TOWER PLUMBING REP AIR P ARTS 1 11 4 5 4 7 10 6 14 12 13 5 4 16 11 2 8 2 3 2 3 3 17 15 9 18 19 18 18 18 ITEM NO. QTY. PART NO. DESCRIPTION 1 1 Y221000 TOWER, 2 PERSON SHOWER 2 3 U401000 FTG, ELL, .50" FST x 10 mm BARB 3 4 Y724000 1/2" ELBOW, SLIP x THREAD, SCH 40 4 3 7164000 ELL, STREET, .
21 Jacuzzi Whirlpool Bath © BY82000 03/05.
Printed in U.S.A . Jacuzzi Whirlpool Bath © BY82000 03/05 Printed on Recycled Pape r Jacuzzi Whirlpool Bath National Headquarters P.O. Box 702168, Dallas, TX 75370-2168 Service Support: (800) 288-4002 PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Jacuzzi Whirlpool Bath P .O. Box 702168 Dallas, TX 75370-2168 WARRANTY COVERAGE Jacuzzi Whirlpool Bath (the “Company”) offers the following express limited warranty to the original purchaser of any Jacuzzi Whirlpool Bath Designer Collection Bath Product (“unit”) who purchases the product for personal or single family use (“user”).
RESPONSIBILITIES OF OTHERS Inspecting the unit prior to installation is the responsibility of the installer or building contractor who acts on behalf of the user. They are responsible for ensuring the unit is free of defect or damage. Notices are placed on and in the unit and on the shipping carton advising the installer of this responsibility.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Jacuzzi BY82000 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Jacuzzi BY82000 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Jacuzzi BY82000, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Jacuzzi BY82000 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Jacuzzi BY82000, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Jacuzzi BY82000.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Jacuzzi BY82000. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Jacuzzi BY82000 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.