Intel® RAID Controller SRCSASPH16I Hardware Guide i Intel ® RAID Controller SRCSASPH16I Hardware Guide Intel Order Number: E33256- 001.
ii Intel® RAID Controller SRCSASPH16I Hardware Guide INFORMATION IN THIS DOCUMENT IS PROVID ED IN CONNECTION WITH INTEL(R) PROD- UCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY R IGHTS IS GRANTED BY THIS DOCUMENT.
Intel® RAID Controller SRCSASPH16I Hardware Guide iii Preface This is the primary reference and user ’ s guide for the Intel ® RAID Controller SRCSASPH16I, which can be used for SAS and SA T A disk drives. It contains installation instructions and specifications.
iv Intel® RAID Controller SRCSASPH16I Hardware Guide.
Intel® RAID Controller SRCSASPH16I Hardware Guide v Figures Figure 1. Inserting the Intel ® RAID Controller SRCSASPH16I into a PCI Express* Slot ........................................................................... ............................
vi Intel® RAID Controller SRCSASPH16I Hardware Guide.
Intel® RAID Controller SRCSASPH16I Hardware Guide vii Contents Preface .............. ................................. .............................. ............... ........................... .i i i Audience .......................................
viii Intel® RAID Controller SRCSASPH16I Hardware Guide.
Intel® RAID Controller SRCSASPH16I Hardware Guide ix Tables Table 1. Jumper Descriptions ........................................................ .......................................... 12 Table 2. Specifications ..................................
1 Intel® RAID Controller SRCSASPH16I Hardware Guide 1O v e r v i e w This chapter provides a ge neral overview of the Intel ® RAID Controller SRCSASPH16I.
Intel® RAID Controller SRCSASPH16I Hardware Guide 2 The SAS controller supports the ANSI Serial Attached SCSI (SAS) standard, version 1.0. In addition, the controller supports the Serial A T A (SA T A) protocol defined by the Serial A T A specification, version 1.
3 Intel® RAID Controller SRCSASPH16I Hardware Guide • User specified rebuild rate (% of system resources to use from 0-100%). W ar ning: Exceeding 50% rate may caus e operating system e rr ors caused by waiting for contr oller access.
Intel® RAID Controller SRCSASPH16I Hardware Guide 4 — I/0 setting: Determines whether to read /write from cache to improve performance: ^ Cache I/O: W rites to the cache and next rea d checks the cache first. ^ Direct I/O: Never uses cache, all data goes from host to disk to host.
5 Intel® RAID Controller SRCSASPH16I Hardware Guide Operating System Support The RAID Controller SRCSAS PH16I suppor ts major operating systems, including: • Microsoft W indows Server 2008*, Mic r oso ft W indows Serve r 2003*, and Microsoft W ind ows XP* • Red Hat* Enterprise Linux 4.
Intel® RAID Controller SRCSASPH16I Hardware Guide 6 not inhibit airflow . The point-to-point SA T A architecture eliminates inherent difficulties created by the legacy A T A mast er -slave architecture, while maintaining compatibility with existing A T A firmware.
7 Intel® RAID Controller SRCSASPH16I Hardware Guide 2I n t e l ® RAID Controller SRCSASPH16I Hardware Installation This chapter describes the proced ures used to install the Intel ® RAID Controller SRCSASPH16I with internal and extern al connectors.
Intel® RAID Controller SRCSASPH16I Hardware Guide 8 Installation 1. Power off the computer and all drives, en closures, and system components. Remove the power cord from the computer . 2. Remove the chassis cover and access the PCI Express add-in card slots.
9 Intel® RAID Controller SRCSASPH16I Hardware Guide — Plug the cable into co nnector at the inside edge of the adapter . Figure 2. Connecting the Disk Drive Note: System thr oughput pr oblems can occur if us ing SAS cables that do not come with the RAID contr oller and that ar e not the corr ect ty pe.
Intel® RAID Controller SRCSASPH16I Hardware Guide 10 10. W atch the boot process until you see a BIOS message to info rm you of the key combination to press to enter the RAID BIOS Console. It will look similar to the following message: Press <CTRL><G> to run BIOS Console 2.
11 Intel® RAID Controller SRCSASPH16I Hardware Guide Configuring the Storage Adapter After performing the Intel ® RAID Controller SRCSASPH16 I installation, you must configure the storage adapter and inst all the operating system driver .
Intel® RAID Controller SRCSASPH16I Hardware Guide 12 3I n t e l ® RAID Controller SRCSASPH16I Characteristics This chapter describes the characteristics of the Intel ® RAID Controller SRCSASPH16I. Figure 4 displays the c onnectors and headers on the controller and T a ble 1 describes them.
13 Intel® RAID Controller SRCSASPH16I Hardware Guide Technical Specifications The design and implementation of the Intel ® RAID Controller SRCSASPH16I minimizes electromagnetic emissions, susceptibility to radio frequency energy , and the effects of electrostatic discharge.
Intel® RAID Controller SRCSASPH16I Hardware Guide 14 T able 2 lists the specifications for the Intel ® RAID Controller SRCSASPH16I . Array Performance Features T able 3 shows the RAID Controller SRCS ASPH16I array performance features.
15 Intel® RAID Controller SRCSASPH16I Hardware Guide Fault Tolerance T able 4 shows the RAID Controller SRCSASPH16I fault tolerance features. Maximum Size of I/O Requests 6.
Intel® RAID Controller SRCSASPH16I Hardware Guide 16 Electrical Characteristics This section provides the power requirements for the RAID Cont roller SRCSASPH16I. T able 5 lists the maximum power requirements. Thermal and Atmospheric Characteristics Table 6.
17 Intel® RAID Controller SRCSASPH16I Hardware Guide Safety Characteristics The RAID Controller SRCSASPH16I meet s or exceeds the requirements of UL flammability rating 94 V0. Each bare board is also marked with the supplier name or trademark, type, and UL flam mability rating.
Intel® RAID Controller SRCSASPH16I Hardware Guide 18 A Glossary of Terms and Abbreviations BIOS Basic Input/Output System. Software that provides basic read/write capability . Usually kept as firm wa re (ROM based). The system BIOS on a server board is used to boot and control the system .
19 Intel® RAID Controller SRCSASPH16I Hardware Guide SAS Serial Attached SCSI. A serial, point-to-poi nt, enterprise-level device interface that leverages the proven SCSI protocol set.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Intel SRCSASPH16I c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Intel SRCSASPH16I - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Intel SRCSASPH16I, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Intel SRCSASPH16I va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Intel SRCSASPH16I, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Intel SRCSASPH16I.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Intel SRCSASPH16I. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Intel SRCSASPH16I ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.