Manuel d'utilisation / d'entretien du produit 831.21007 du fabricant Image
Aller à la page of 20
¨ USERÕS MANUAL Model No. 831.210070 Serial No. The serial number can be found in the location shown below . Write the serial number in the space above. CAUTION Read all precautions and instruc- tions in this manual before using this equipment. Save this manual for future reference.
T ABLE OF CONTENTS IMPORT ANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 BEFORE YOU BEGIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 IMPORT ANT SAFETY INSTRUCTIONS W ARNING: TO REDUCE THE RISK OF DROWNING, ELECTRIC SHOCK, OR SERIOUS INJUR Y , READ THE FOLLOWING IMPORT ANT PRECAUTIONS BEFORE USING THE RENEW 207. READ AND FOLLOW ALL INSTRUCTIONS 1. It is the responsibility of the owner to ensure that all users of the RENEW 207 are adequately informed of all precautions.
4 20. Do not use an extension cord with the RENEW 207; this could damage the motor and will void the warranty . 21. DANGERÑIf you will be using the RENEW 207 outside, do not bury the power cord. Keep the power cord away from lawn mow- ers, hedge trimmers, and other similar equip- ment.
34. W ARNINGÑT o reduce the risk of injury or drowning: Consult your physician about pos- sible side-effects of any medications you may be taking before using the RENEW 207. Heat from the water , in conjunction with some medications, may cause drowsiness and increase the risk of drowning.
6 BEFORE YOU BEGIN Spa Shell Wood Panels Cover Latch Locking Buckle Console Filter Spa Cover Power Cord Ground Fault Circuit Interrupter (GFCI) Access Cover Congratulations for selecting the new IMAGE ¨ RENEW 207 massage spa.
7 CHOOSING A LOCA TION FOR THE RENEW 207 There are many factors to consider when choosing a location to set up the RENEW 207. These factors vary depending on whether you plan to use the spa inside or outside. We have listed several factors you may wish to consider as you decide where you want to set up the spa.
1. Before beginning assembly , make sure that you have read and understand the information in the box above and on the previous page. Remove the four screws from the access cover on the console side of the spa. Remove the access cover by sliding it down and then pulling the bottom of it away from the spa.
4. Attach the nozzle of the included air pump to the valve on the Insulating Liner (4). Fill the Insulating Liner with air . Be careful not to overfill the Insulating Liner . Lay the Spa Cover (1 1) on the floor as shown. Set the Insulating Liner (4) inside the Spa Cover .
10 USING THE RENEW 207 The RENEW 207 is designed to seat two adults. The spa holds 150 gallons of water and offers an automat- ic, programmable heating (70¡ F to 104¡ F) and filtra- tion system. Seven thera-jets soothe and relax tired, sore muscles, and the strength of the massage is adjustable.
TESTING AND TREA TING THE W A TER The hydrotherapy spa comes with a starter chemical pack for maintaining the water in the spa. Disregard the directions on the individual packages of ÒQUICK pHix It DOWNÓ and ÒQUICK pHix It UP .Ó However , the directions on the bottle of ÒNon-chlorine ShoxÓ and ÒBromine BaseÓ are correct.
12 SECURING THE SP A COVER The spa cover can be secured by snapping the latches on the spa cover into the buckles on the side of the spa. The buckles can be locked by inserting the key and turning it clockwise 1/4 turn. T o unlock the buck- les, insert the key and turn it counter- clockwise 1/4 turn.
13 The RENEW 207 is designed to provide years of enjoyment. Follow the guidelines below to properly maintain the spa. MAINTENANCE SCHEDULE DAIL Y ¥ Check the water level. If necessary , refill the spa to the level shown in step 3 on page 8. ¥ Adjust the pH balance and sanitizer level if needed (see W A TER CHEMISTR Y on page 14).
14 W A TER CHEMISTR Y The hydrotherapy spa comes with a starter chemical pack for maintaining the water in the spa. (See TEST- ING AND TREA TING THE W A TER on page 1 1.
15 T o drain the RENEW 207, follow these steps: 1. Set the temperature control on the console to the lowest setting. 2. Unplug the power cord. 3. Remove the access cover from the spa. 4. Remove the drainage hose from the clip and attach a garden hose to the valve on the drainage hose.
16 1. SYMPTOM: THE SP A WILL NOT OPERA TE a. Check the power cord. The power cord must be plugged into a grounded outlet (see PLUGGING IN THE RENEW 207 on page 10). b. Check the GFCI breaker to see if it is tripped or if it was not turned on. Reset the GFCI breaker .
17 8. SYMPTOM: THE W A TER PULSA TES OR THERE IS MINIMUM W A TER FLOW a. This usually occurs only when the water level is low . Add water to the level shown in step 3 on page 8. b. The filter may be dirty . Check the filter and clean it if necessary .
18 P ART LISTÑModel No. 831.210070 R0400A Note: Ò#Ó indicates a non-illustrated part. Specifications are subject to change without notice. Key No. Qty .
32 26 5 1 2 3 4 6 11 13 15 2 14 16 28 29 37 7 19 20 21 12 9 25 22 23 30 31 39 24 27 42 34 33 18 41 35 8 10 10 17 17 40 43 43 40 36 40 38 3 4 EXPLODED DRA WINGÑModel No.
ORDERING REPLACEMENT P ARTS T o order replacement parts, simply call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday , 6 a.m. until 6 p.m. Mountain T ime (excluding holidays). T o help us assist you, please be pre- pared to give the following information when calling: ¥ The MODEL NUMBER of the product (831.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Image 831.21007 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Image 831.21007 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Image 831.21007, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Image 831.21007 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Image 831.21007, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Image 831.21007.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Image 831.21007. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Image 831.21007 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.