Manuel d'utilisation / d'entretien du produit MSM-508 du fabricant ICP DAS USA
Aller à la page of 27
April 29, 2008 TM Web Management Us er Manual Industrial Managed Ethernet Switch Version 1.0 This document applied to models of MSM-5 08,MSM-508FC /FCS/FT C o p y r i g h t © I C P D A S C o .
April 29, 2008 CONTENTS 1. Web Connectio n .......................................................................... 2 2. Basic Setting ............................................................................... 4 Informati on ............ ..
April 29, 2008 10. Authentication ..................................... ..................................... 22 Account ........ ............ ............ ........... ........ ............ ............ ......... 22 Accessi ble IP ............
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 1 Connection Basic Setting Redundant Setting Port configurat ion Relay Alarm Email Alar.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 2 1. W eb Connection The default net work setting (fac tory default setting) of Manage d Switch is : IP : 192.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 3 For log in to Web Managem ent, your browser m ust support HTTP authentication.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 4 2. Basic Setting This chapter desc ribes ho w to setting the c omm only inform ation on your Managed Switch. Information Module Name : : : : Use to specif y the Switch N ame, and als o displa yed as the console prom pt.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 5 Onl y MS Series Switch s upports a real tim e clock . For RS Series S witch, the <Date Ti m e Setting> f unction is inval id. Network IP Address : : : : IP address is an identifier f or a de vice on a TCP/IP network .
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 6 Mask : : : : The (subnet) M ASK is used to determ ine the subnet of an IP address. Same as th e IP address, a MASK contains four bytes (32 bit s) and it is often ex pressed in the dotted-decim al notation.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 7 COM1 port is t he RS232 standar d, use for Co nsole Connec tion. Factor y default setti ng is: Baud Rate : 1 15 200 Data Bit : 8 Parity Check : 0 (None) S top Bit : 1 COM2 is the R S485 standard, use f or Modbus com m unication.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 8 3. Redund ant Setting Redundant LAN t opolog y is a structur e to provide t he link failure recover y and escaping n etwork loops. It allows you t o setup the re dundant l oops for supporting bac kup connect ions.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 9 Recovery T i me Setting Recovery Time (C yber-Ring Prot ocol) : : : : Recover y time is the durat ion of conn ections that f rom failure oc curred to retur n to norm al.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 10 Forward Time (ST P Protocol) : : : : Forward dela y is the durati on tim e that packages from pre- forwarding s tate to forward state. Factory default is 10000ms , the variable is from 4000ms to 3 0000m s (30 sec).
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 1 1 4. Port configuration Mirror Mirror Port sett ing is comm onl y used to m onitor the network traffic, it can help you to collect and trace abnorm al packets of each port without interrup ting data transm ission.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 12 T runking This f unction is used for s etting the groups of link aggregation . Port trunk ing allows user to combine m ultiple ph ysical ports into a single l ogical cha nnel.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 13 Port P ort Num ber Speed P ort transm ission speed. ( 10 Mbps / 100 M bps ) Duplex Fl ow Control M ode. Both H alf-duplex an d Full-duplex modes ar e supported.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 14 5. Relay A larm Managed Switch offer a relay contact output on T erminal Block of the Switch equipm ent. It is able to connect to a l ight, bu zzer …etc. warnin g device and notify s ystem f ailures imm ediately .
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 15 6. Email A larm ICPDAS Manag ed Switch c an notify you by email whe n the specif ied event occ urred. This chapter will guide you how to sett ing the related parameter s.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 16 Email Setting User can selec t “Disable A larm Mail” to stop the em ail alarm sending (f actory default). If email alarm is enabled, th ere are two m ethods of em ail report for you select.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 17 Email Record Switch Managem ent can k eep the sending date, tim e and status of each w arning em ails. But only the lat est 50 send ing records will be saved.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 18 7. VLAN Virtual LANs (VLAN) allows you to setting logical groups of devices, even they are not located on the same physical segment.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 19 Port based VL A Ns In this function , user can de term ine the output ports whic h this input port c an send fr ames to. For example, in above figure, onl y the ingress come fr om Port 4 and Port 8 can be send out from Port 1.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 20 8. QoS Quality of Ser vice (QoS) pr ovides diff erent priority to di fferent data flow . It can m ake you to classif y and prioritize data fram es. ICPDAS Manag ed Switch s upport 4 classes of servic es priorit y queues.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 21 IP T oS/DiffServ Enable/Disabl e specified p orts using the TOS (T ype of Service) a nd/or DiffServ (Differentiated Service) f ield in IPv4 fr ame. 802.1p T ag over T os/Diff Serv If <802.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 22 9. Diagnosis Ping In this function , user can in put the IP address and cl ick SUMIT button to c heck if the IP is reachable.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 23 At the system initial, the def ault account and password are: Admin and A dmin . Accessible IP Y ou can set the rem ote IP address here to f ilter the illega l access.
Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 24 Default Setting This f unction allows you to clean all sett ings and lo ad the def ault value to S witch Managem ent. Current factor y default val ues are : Netwo rk Setting IP A ddress : 192.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté ICP DAS USA MSM-508 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du ICP DAS USA MSM-508 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation ICP DAS USA MSM-508, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le ICP DAS USA MSM-508 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le ICP DAS USA MSM-508, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du ICP DAS USA MSM-508.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le ICP DAS USA MSM-508. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei ICP DAS USA MSM-508 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.