quick start guide hp surestore fc 1Gb/2Gb switc h 16B www.hp.c om.
Notice © Hewle tt- Pa ck ard C ompa n y , 2001. Al l rig ht s reserv ed. Part numbe r: A73 40-96 002 Edition : E1201 Hewlett-Pa ckard Comp any makes no war ranty of any kind wi th regard to thi s material , includ ing, bu t not limited to , the imp lied warrantie s of merchanta bility and fitness for a particular purpose.
iii Revision Histor y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Related Publ ications . . .
iv Quick Sta rt Guide Next Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Settin g QuickLoop Mode o n Ports . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Settin g Up Speed Negotia tion .
v Revision History Up dat es For the m ost curr ent in formatio n about the HP Sures tore FC 1Gb/2Gb Switch 16B, visit th e support W eb sit e located at http://www .hp.com/sup port/fc16B . For infor mati on about product availa bili ty , configur ation , and co nnecti vity , consult your HP accou nt representat i ve.
vi Quick Sta rt Guide For info rmation about Fibre Channe l standards, vi sit the Fibre Cha nnel Associat io n W eb site, loc at ed at http: //www .fibrechannel.c om . Distri buted Fabri cs User’s Gu ide , version 3.0 A vailabl e only on CD Zoning User ’s Guide , versio n 3.
1 1 INST ALLING THE SWITCH Product Descripti on The HP Sures tore FC 1Gb/2 G b Swit ch 16B is a 16-port Fi bre Channel gigabit switch t hat suppor ts link speeds u p to 2 Gbps. Each port automa ticall y negoti ates to the highest common sp eed of all devic es connecte d to the port.
2 Quick Sta rt Guide • The ambient air temper ature ne ar the swit ch must not e xceed 40 degr ees Cels ius. Th is is p ar ticul arly im p orta nt to v er ify if t he sw itch is in stall ed in a clo sed or multi- rack assembly . • The vo lume of ai r flow av ailable to the s witch must be at le ast 300 cu bic feet pe r minute.
Install ing the Switc h 3 • Four r ubber mou nting fee t (used only for sett ing up t he switch as a sta nd -alon e uni t) • T wo rails and one bag of rail mountin g hardware (required i f the swi.
4 Quick Sta rt Guide b. T urn on the p ower supply (flip the AC swit ch to “I”) when ready t o supply po w er t o the swit ch. The s witch aut omatically runs POST (pow e r on se lf-tes t) eac h time it is turn e d on. c. If the FC 16B includes a second power supply , repeat Steps 4a and 4b for the remaining power supply .
Install ing the Switc h 5 The foll owing items ar e require d to install t he switch in a ra ck: • FC 16B switch • Pow er ca bles • #2 Phill ips and T25 T orx scre wdrivers • Rails an d rail m.
6 Quick Sta rt Guide CAUTION For prope r airfl ow , the SFP media side of t he FC 16B faces the rear of the rack. Th is mountin g allo ws air to ent er f rom the front of the r ack and to ex haust at the rea r of the rack, similar to ot her rack- mounted equipment.
Install ing the Switc h 7 – Fo r a Com paq/R ittal r ack, as sembl e each of the two b rackets with (2) spacers , (2) M5 flat washe rs, and (1) M5 T orx head screw with capti ve loc k was h ers as show n in Figure 3 . Note For t he Co mpaq/R itta l rack, th e alig nment pins w ill be restin g on the top surfaces of the spacers.
8 Quick Sta rt Guide Figure 4. Inst alling the Tin nerman Clips (HP Rack) – For a Compaq/Ritta l rack, instal l (2) #10- 32 square T innerman nu ts for eac h of the front co lumns of the rack in the top and bottom positi ons of the three -hole EIA pa ttern.
Install ing the Switc h 9 5. A ssemb le the outer ra ils by comple ting the fo llowin g step s: a. As an ai d in assembly , two rubber was hers have been i ncluded to hel p keep the rear slotted p ortion of the ou ter rail flus h against the r ear rail-t ray br acke ts.
10 Quick Sta rt Guide Figure 7. Assemb ling the Outer Ra ils (HP Rack) – For a Compaq/Rit tal rac k, instal l one #10-32 x 5 / 8 Phillips pan-head screw in the upper hole loc ation of the ri ght rail . Then, instal l one # 10-32 x 5/8 Phillips pan-he ad screw in the lower locat ion of the left rail.
Install ing the Switc h 11 CAUTION Do not use any other s crews other than the si x that are provided. Use of any longer lengths c an cause da mage to internal components of the switc h. Bef ore ti ghten ing s cr ews, m ake s ure th at the ra ils are cente red to the ov erall h eight of the swit ch.
12 Quick Sta rt Guide b. T urn on the p ower supply (flip the AC swit ch to “I”) when ready t o supply po w er t o the swit ch. The s witch aut omatically runs POST (pow e r on se lf-tes t) eac h time it is turn e d on. c. If the FC 16B includes a second power supply , repeat Steps 8a and 8b for the remaining power supply .
13 2 SETUP System Componen t s The HP Sures tore FC 1Gb/2Gb Swit ch 16B co nsists of t he following components : • A 1U ch ass is , de si gned to be mounte d i n a 19-inch ra ck, wit h forced-a ir cooling that flows from the p ower supply side of t he switch to the SFP medi a s ide.
14 Quick Sta rt Guide – One LED in the cente r of the power supply si de to indicat e the over all sw itch s ta tus. • T wo universal input a nd redundant power s upplies with AC swit ches and buil t-in fans. The powe r supplies plug into int e rnal blind-mat e connecto rs when installed i n the chassis.
Setup 15 The ports on the SFP media sid e of the FC 1 6B are color -coded in groups with four purple ports a lternat ing with f our unmarked ports to indicate which ports can be used in the same ISL T runking group.
16 Quick Sta rt Guide T o turn the FC 16B on, co nnect one or both power suppli es to a power sourc e, th en fli p the AC powe r swit ch to th e “I” p ositi on. T o turn th e switc h of f, turn off bo th power supplies ( if bot h ar e in stalled) by fli ppi ng e ach AC power swit ch to the “O” p osition.
Setup 17 GBIC optic m odul es. LC to SC cab les or ad apters are r equired t o connect the cabl es together . T o connect an SC cable to th e FC 16B, us e the HP C7540A - 2M LC male - SC ma le cab le ada pter . Connect i nter switch li nks (ISLs) between two FC 16B s witches us ing an LC to LC cable.
18 Quick Sta rt Guide • W o rk stati on tha t has a te rmin al emul ator a pplic ation (s uch a s HyperT erminal) • Serial cable provided wi th the switch, fo r connecting the switch to the workst.
Setup 19 – In a UNIX envi r onment , en te r t he f ol lowing string at th e prompt: tip /dev/ttyb -9600 f. From t he term inal e mula to r app lic ation , log o n to th e s witch with administ rative privil eges thr ough the serial connection. The de fault administ rative logon is admin and the default pas sword is password .
20 Quick Sta rt Guide Note The seria l port i s intende d only for use duri ng the ini tial s etting of the IP ad dress and for se rvice purposes. Us ing the serial port during normal swi t ch operation o r for regular mai ntenance is not recomme nded.
Setup 21 a. D isabl e the s witch b y ente ring the fo llo win g: switchDisable b. E nter the follo w ing: configure c. E nter th e follo wing at the Fabric parameters prompt: y d.
22 Quick Sta rt Guide c. Connect t he cables to the SFPs as app ropriate to the fabric t opology . Positi on each cabl e so t hat t he key ( the ri dge on o ne sid e of th e cabl e connecto r) is aligned wi th th e slot in the SFP . Then, inser t the cable into the S FP unt il it is firmly seat ed an d the la tchin g mec hanism clic ks.
Setup 23 1. V eri fy that the RSHD s ervice ( on a UNIX machin e) or the FTP servi ce (on a W indows machine) i s running on the ho st workstation. 2. Login to t he switch as the admin user .
24 Quick Sta rt Guide system con figuration fil e, and password is th e pas sword for th e use r ID specif ied. Note The passwor d operand i s only required if you are using FTP .
Setup 25 Configuring Supported Dev ices HP Surestore Director FC-64 Switch The FC 16B swit ch can be used wit h the HP Surestore D irect or FC-64 switch.
26 Quick Sta rt Guide HP Surestore V A 7400 The FC 16B also can s upport a 2Gb connection to an HP Surestore V irtual Array 7400 . Set the port spe ed to 2Gb usi ng the telnet c ommand portCfgSpeed . Use the V irtual Front Panel (VFP ) on the V A 7400 an d configur e the devic e as fol lows : 1.
27 3 DIAGNOSTICS Switch St atus Indicators System activit y and status can be determined thr ough the activi ty of the LED s on th e swi t c h. Note The LEDs may fl ash yellow during diagnostic tes ts; gree n, yellow , or orang e during POST .
28 Quick Sta rt Guide • One swit ch status LED in th e center of th e power supply side t o indicate whether t he switch is on and has succ essfully booted , and whether an y of the po rts are fault y . LEDs on the SFP Media S ide Figure 12 shows the SFP medi a side of t he FC 16B with the LEDs iden tified.
Diagn ostics 29 The followi ng table desc ribes the LEDs ab ove each port on th e right. These LEDs indic ate the speed of the port. Fast-fla shing green (on 1 / 4 second; of f 1/4 second) The por t is in int ernal l oopback (diag nosti c). No actio n require d.
30 Quick Sta rt Guide The foll owing table descr ibes the LEDs belo w the serial por t. These LEDs indicat e the swit ch power . LEDs on the Pow er Supply Side Figure 13 shows t he power supp ly side of the s witch with the LEDs iden tified. Figure 13 .
Diagn ostics 31 The foll owing tab le describe s the LEDs on each powe r supply . These LEDs indicat e the st atus of the rel a ted power supply . The foll owing table descr ibes the LED in the cente r of the power supply side. This L ED ind icate s the st atus o f the s witch .
32 Quick Sta rt Guide Maintenance and Diag nostic T est s The FC 16B does not re quire any regular physica l maintenance, an d is designed to minimize th e chance of failure, incl uding dia gnostic t ests and field- replace able units. Diagnost ic tests are pr ovided to help troublesho ot the hardware a nd the firmware .
Diagn ostics 33 Note The trans m it and recei ve spee d of the l inks may b e temporar ily locked t o a specific sp eed during dia gnostic t esting. Con tent Addressa ble Me m ory (CA M ) Te s t camT est V erifies CAM functionali ty . Run of fline. Port Loopbac k Te s t por tLo opback T es t Check s all swit ch main board hardwar e.
34 Quick Sta rt Guide Error Messages T o analyze error m ess ages, acce ss the error mess age log via a T elnet session usi ng the errDump c ommand. Note any mess ages be fore r emoving power fr om the switch; err or mess ages are s t ored in RAM and ar e lost when power is r emoved.
35 4 S PECIFICATIONS Genera l The followi ng table lists the gener al speci fica tions fo r the HP Surestore FC 1Gb/2Gb Switch 16B. Specific ation D escri ption Fabric init ializa tion C omplies wit h FC-SW 5.0 IP over Fib re Channel (FC-IP) Complies with FC-IP 2.
36 Quick Sta rt Guide Environment al The foll owing table lis ts the acceptab le environmental ranges. Mo des of ope ration Fibre Channel Clas s 2 and Class 3 Aggregat e switch I/O bandwidth 64 Gbps i.
Specific ation s 37 Dimensions The foll owing table lis ts the di mensions of the FC 16B. Power Supply The foll owing table lis ts the powe r supply specifi cations . V ibration (non-ope rating) 10 G , 0-5 kHz at 1.0 octave/ minute Condition Ac cept able Range Dim en sion Va l u e Height 1U Dept h 24 i n ches ( 61.
38 Quick Sta rt Guide.
39 PRODUCT REGULATORY INFORMA TION FCC EMC St atement (USA) This equipment has been tested and found to com ply with th e limits for a Class A digital device, pursuant to Part 15 of the FC C Rules.
40 Quick Sta rt Guide Germany Nois e Declarati on Schalldr uckpegel Lp = 46 .1 dB(A) Am Arb eits platz (ope ra tor po siti on ) Normaler B etrieb (norm al operation) Nach ISO 7779:19 99 ( T ypprüfung.
Product Re gulatory Inform ation 41 Laser Safety A. Certi fication and Cl assification Info rmation When equipped with n ative Fibre Channel adapters, this product contains a laser internal to the small form factor plug gable (SFP) transceiver modules.
42 Quick Sta rt Guide Declaration of Confor mity DECL A R A T ION OF CONFOR MITY acc ordin g to I SO/ IEC G ui de 2 2 and EN 45 014 Manufacturer's Nam e: Hewle tt-Packard Company Networ k Stor age S olutions Organiz ation M a nu fact urer's A ddress: 8000 Foothills Blvd.
.
.
.
Technical information in this docum ent is subject to change without notice. © Copy right Hewl ett-Packard Company 2001. All right reserved. Reproduction, adaptation, or trans latio n without prior written permission is prohibited except as allowed under the copyright laws.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté HP (Hewlett-Packard) A7340-96002 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du HP (Hewlett-Packard) A7340-96002 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation HP (Hewlett-Packard) A7340-96002, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le HP (Hewlett-Packard) A7340-96002 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le HP (Hewlett-Packard) A7340-96002, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du HP (Hewlett-Packard) A7340-96002.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le HP (Hewlett-Packard) A7340-96002. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei HP (Hewlett-Packard) A7340-96002 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.