Manuel d'utilisation / d'entretien du produit fps50 du fabricant A.O. Smith
Aller à la page of 103
~ ~ -- ~- I';:::;:: t;;.i( - --- -- ~ ' , ~ K -r~~ : --' :::=::;- ~ ( ;,,' tF ~~~. ~ 0-'1 ~ n ; q F' ~;;;;~~, n II : ~ r =~~~ ~~~ Models FPS 40 and 50 Series 226-227 FPSE 40 and 50 Series 226E FPD 40 and 50 Series 226-227 ruc Wc ~~D~w Prepared by the Technical Information Dept.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK WORKBOOK INTRODUCTION Technical Information Irvino. Texas 1 @1995 A.D. Smith Water Products Co..
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK TABLE OF CONTENTS SUBJECT PAGE PAGE SUBJECT Service and Operation Choosing the Best Water Heater 3 FPS 40 & 50 Introduction 21 When to choose t.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK CHOOSING THE BEST WATER HEATER Technical Information Irving, Texas 3 @1995 A.D. Smith Water Products Co.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK CHOOSING THE BEST WATER HEATER cant..
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK CHOOSING THE BEST WATER HEATER cant..
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK VENTING INSTALLATION.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK VENTING INSTALLATION cant. Exterior installation clearance requirements are crucial and must be met to ensure compliance with all safety and code requirements. If all clearances cannot be met, do not unpack the heater.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK VENTING INSTALLATION cant. Exterior installation clearance requirements are crucial and must be met to ensure compliance with all safety and code requirements. If all clearances cannot be met, do not unpack the heater.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK VENTING INSTAllATION cant..
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK VENTING INSTAllATION cant..
VENTING INSTAllATION cant..
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK VENTING INSTAllATION cant..
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK VENTING INSTAllATION cant..
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK VENTING INSTALLATION cant..
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK VENTING INSTAllATION cant.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK AIR FOR COMBUSTION Checking for Draft On initial start up, check for the correct draft on the Power Shot. To check the draft, place a smoke stick directly in front of the inlet air damper while the heater is firing.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK AIR FOR COMBUSTION cant. SOLUTION CONDITION CAUSE Seal vent joints Burnt gas odor when heater is operatinq Leaking vent joints Blocked vent Clear vent blockaQe The majority of the complaints associated with the operation of the will likely be a direct result of improper venting.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK AIR FOR COMBUSTION cont. CONDITION CAUSE SOLUTION Free air damper Excessive heat build-up in PVC venting Inlet air damper not opening completely Bl.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK AIR FOR COMBUSTION cont. Negative Pressure Diagnosing pilot outage complaints requires an examination of the environment in which the heater is installed. Mechanical vent fans are the chief cause of negative pressure.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK AIR FOR COMBUSTION cont. A.D. Smith Water Products Co Technical Information Irving, Texas 20.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cant. -A~I DISCONNECT FROM ELECTHICAL SUPPLY BEFORE SERVICING UNIT. REPLACE ALL DOORS AND PANELS BEFORE OPERATING HEATER. ~ "" 115~LT POWER SOURCE CONNECTOR, Gim "" w ~ ~ I O/Y.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cant. Technical Information Irving, Texas 23 @1995 A.D. Smith Water Products Co.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cant Trouble- shooting cont PRELIMINARY CHECKS 1. Gas valve knob is in ON position 2. Pilot is burning 3. 120 VAG is supplied to heater. (See page 25) 4. Thermostat is calling for heat 5.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cant. Trouble- shooting cont..
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cant. @1995 A.D. Smith Water Products Co. Technical Information Irving, Texas 26.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cont. BLOWER DOES NOT RUN cant. Trouble- shooting cont. RESULTS If: then: the fan does not run, replace the fan assembly. the fan does run, go to Step 2. @1995 A.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cant. BLOWER DOES NOT RUN cont. Trouble- shooting cont. RESULTS If: then' replace the cable the fan does not run, go to Step 3.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cant. BLOWER DOES NOT RUN cant. Trouble- shooting cont RESULTS If: then replace the harness the fan does not ru.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cont. Technical Information IrvinQ, Texas 30 @1995 A.D. Smith Water Products Co.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cant BLOWER RUNS CONSTANTLY (No call for heat) cont Trouble- shooting cont RESULTS If: then replace the fan assembly the fan continues to run, go to Step 2 the fan stops, @1995 A.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cant. BLOWER RUNS CaNST ANTL Y (No call for heat) cant. Trouble- shooting cont.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTLY (No call for heat) cant. Trouble- shooting cont. RESULTS If: then: the fan continues to run, replace the harness the fan stops, replace the gas pressure switch.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cant @1995 A.D. Smith Water Products Co. Technical Information Irving, Texas 34.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cant BLOWER RUNS CONSTANTLY (No main burner) cont. Trouble- shooting cont. RESULTS If: then the meter does not read 120 VAG, replace the air switch the meter does read 120 VAG, go to Step 2 Technical Information Irving, Texas 35 @1995 A.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cant BLOWER RUNS CONSTANTLY (No main burner) cant. Trouble- shooting cont. RESULTS If: then the meter does not read 120 VAG, replace the cable the meter does read 120 VAG, go to Step 3 Technical Information Irving, Texas 36 @1995 A.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTLY (No main burner) cont. Trouble- shooting cont. RESULTS If: then: the meter does not read 120 V AC replace the harness the meter does read 120 V AC, replace the solenoid.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cont PILOT PROBLEMS Trouble- shooting cont. The following are possible causes of pilot problems: 1. Incorrect pilot position; the pilot should engulf the tip of the thermocouple 38" to 12", 2.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 SERVICE AND OPERATION cant. MAIN BURNER PROBLEMS Trouble- shooting cont. The following are possible causes of main burner problems: 1. Unlevel burner will cause yellow flames 2. Burning and the orifice indicates main gas valve may not be fully closing.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 40 and 50 PARTS LIST PSD-1-263/b RESIDENTIAL WATER HEATER PARTS LIST MODELS FPS-40 AND 50 SERIES 226/227 L;'~ @).,~ ffi]'G;J WATER PRODUCTS COMPANY 5621 W. 115TH STR~~T, ALSIP, ILLINOl5 60462/1-600-433-2545 April 1994 Technical Information Irving, Texas 40 @1995 A.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK S,~i,s22§!:2~Z ~Ef§.;?Q 43fl17-;oS 4.38' 7-Je 181382 181382 161360 16'360 161920 16'920 161936 18'9362: 181g36-1 IB1936-3 IBI806 181806 !!!!!! 1 2 3 4 5 D~~ ftpl!Of1 6 7 181805.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION FPD 40 and 50 SERVICE AND OPERATION Technical Information Irving, Texas 42 @1995 A.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK Technical Information Irving, Texas 43 @1995 A.D. Smith Water Products Co..
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cont FPD 40 and 50 SERVICE AND OPERATION cont. Page I Subject I Preliminary Checks Page 45 Page 46 I Blower do.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cont. FPD 40 and 50 SERVICE AND OPERATION cont. @1995 A.D. Smith Water Products Co.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cont. FPD 40 and 50 SERVICE AND OPERATION cont..
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cant. FPD 40 and 50 SERVICE AND OPERATION cant. BLOWER DOES NOT RUN cont. Trouble- shooting cont. RESULTS If: then the meter does not read 120 VAG, replace the blower assembly.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cant. FPD 40 and 50 SERVICE AND OPERATION cant. BLOWER DOES NOT RUN cant. Trouble- shooting cont RESULTS If: then: the meter does not read 120 VAG, replace the cable.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cont. FPD 40 and 50 SERVICE AND OPERATION cont. BLOWER DOES NOT RUN cont. Trouble- shooting cont. RESULTS If: then the meter does not read 120 V AC replace high limit.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cant. FPD 40 and 50 SERVICE AND OPERATION cant. BLOWER DOES NOT RUN cant. Trouble- shooting cont. Technical Information Irving, Texas 50 @1995 A.D. Smith Water Products Co.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION FPD 40 and 50 SERVICE AND OPERATION cont. @1995 A.D. Smith Water Products Co.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cant. FPD 40 and 50 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTLY (No call for heat) cont. Trouble- shooting cont. RESULTS If: then the blower continues to run, replace the blower.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cant. FPD 40 and 50 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTLY (No call for heat) cant.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cont. FPD 40 and 50 SERVICE AND OPERATION cont. Trouble- shooting cont. BLOWER RUNS CONSTANTLY (CAlliNG FOR HEAT, NO PilOT) First make the Preliminary Checks (see page 45), then perform each of the following tests until cause of the failure is determined: 1.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cant. FPD 40 and 50 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTLY (Calling for heat, no pilot) cant. Trouble- shooting cont. RESULTS If: then: the meter does not read 24 V AC replace the pressure switch.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cant. FPD 40 and 50 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTLY (Calling for heat, no pilot) cant. Trouble- shooting cont. RESULTS If: then the meter does not read 24 VAG, replace the cable.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cant. FPD 40 and 50 SERVICE AND OPERATION cant. Trouble- shooting cont.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cont. FPD 40 and 50 SERVICE AND OPERATION cont. BLOWER RUNS CONSTANTLY (Calling for heat, no pilot) cant Troub.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cant. FPD 40 and 50 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTLY (Calling for heat, no pilot) cant Trouble- shooting cont. Technical Information Irving, Texas 59 @1995 A.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cont. FPD 40 and 50 SERVICE AND OPERATION cont. BLOWER RUNS CONSTANTLY (Calling for heat, no pilot) cant. Trouble- shooting cont. RESULTS If: then: the meter does not read continuity, replace pilot valve.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cont. FPD 40 and 50 SERVICE AND OPERATION cont..
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cant. FPD 40 and 50 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTLY (Calling for heat, pilot is lit, no main burner) cant. Trouble- shooting cont. RESULTS If: then: the meter does not read 24 VAG, replace the 1.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cant. FPD 40 and 50 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTLY (Calling for heat, pilot is lit, no main burner) cont. Trouble- shooting cont. RESULTS If: then the meter does not read continuity, replace main valve.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cant. FPD 40 and 50 SERVICE AND OPERATION cant. PILOT PROBLEMS Trouble- shooting cont. The following are possible causes of pilot problems: 1. An open E.C.O. (high limit) will not allow the heater to relight.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 SERVICE AND OPERATION cont. FPD 40 and 50 SERVICE AND OPERATION cont. MAIN BURNER PROBLEMS Trouble- shooting cont. The following are possible causes of main burner problems: 1. Unlevel burner will cause yellow flames.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPSE 40 and 50 PARTS LIST FPD 40 and 50 PARTS LIST ill.. @J.. ~~ WATER PROOUCTS COMPANY 582' w. , '5TH 8TR~~T. ~l81". IllINOIS 8O.'2rl-800-433-25.5 JUly 1995 P,,'NTED'" V.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK ~n" 222,'223 ~~~~ ~~~? FPSE.40 ~PSE.50 ,~ De~t,pll()tI ~ ~ ~~.Q ~~ A"!J'B Doot L&" . . . . . . 181450 181450 J A.-ode ,.. 43816.38 4J8'6.3a 43817.29 43817.35 .J BaH'e .
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION @1995 A.D. Smith Water Products Co. Technical Information Irving, Texas 68.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. @1995 A.D. Smith Water Products Co Technical Information Irving, Texas 69.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cont. Page Subject Preliminary Checks Page 71 Page 72 Blower does not run Blower runs constantly (No call for heat) Page 76 Blower runs constantly (Calling for heat, no pilot) .
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. Trouble- PRELIMINARY CHECKS shooting cont. Technical Information Irving, Texas 71 A.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant,.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. BLOWER DOES NOT RUN cont. Trouble- shooting cont RESULTS If: then: the meter does not read 120 VAG, replace the blower assembly.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. BLOWER DOES NOT RUN cant. Trouble- shooting cont. j @1995 A.D. Smith Water Products Co.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. BLOWER DOES NOT RUN cant. Trouble- shooting cont. RESULTS If: then: the meter does not read 120 VAG, replace the thermostat. the meter does read 120 VAG, go to preliminary checks.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cont. PRELIMINARY CHECKS EXCEPTIONS 4. Heater should be calling for heat.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTLY (No call for heat) cont Trouble- shooting cont.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTLY (No call for heat) cant. Trouble- shooting cont. RESULTS If: then" the blower continues to run, replace the cable the blower stops, see preliminary checks.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. Trouble- shooting cont. BLOWER RUNS CONSTANTLY (CAlliNG FOR HEAT, NO PilOT) First make the Preliminary Checks (see page 71) then perform each of the following tests until cause of the failure is determined: 1.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cont. BLOWER RUNS CONSTANTLY (Calling for heat, no pilot) cant. Trouble- shooting cont. RESULTS If: then: replace the air pressure switch the meter does not read 24 VAG the meter does read 24 VAG, go to Step 2.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTLY (Calling for heat, no pilot) cont Trouble- shooting cont. RESULTS If: then: the meter does not read 24 VAG, replace the vent high limit. the meter does read 24 VAG, go to Step 3.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cont. BLOWER RUNS CONSTANTLY (Calling for heat, no pilot) cont. Trouble- shooting cont. RESULTS If: then: the meter does not read 24 V AC, replace the blower. the meter does read 24 VAG, go to Step 4.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTLY (Calling for heat, no pilot) cant. Trouble- shooting cont. ~ RESULTS If: then: the meter does not read 24 VAG replace the cable. the meter does read 24 VAG, go to Step 5.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cont. BLOWER RUNS CONSTANTLY (Calling for heat, no pilot) cont. Trouble- shooting cont. RESULTS If: then: the meter does not read 24 VAG, replace high limit the meter does read 24 VAG, go to Step 6.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTL Y'(Calling for heat, no pilot) cant.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant BLOWER RUNS CONSTANTLY (Calling for heat, no pilot) cant. Trouble- shooting cont. RESULTS If: then: the meter does not read 24 V AC, replace the 1.1.0. the meter does read 24 VAG, go to Step 8.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cont. BLOWER RUNS CONSTANTLY (Calling for heat, no pilot) cant. T rouble- shooting cont.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTLY (Calling for heat, no pilot) cant. Trouble- shooting cont.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. Technical Information Irving, Texas 89 @1995 A.D. Smith Water Products Co.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTLY (Calling for heat, pilot is lit, no main burner) cant. Trouble- shooting cont. RESULTS If: then: the meter does not read 24 VAG, replace the I.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. BLOWER RUNS CONSTANTLY (Calling for heat, pilot is lit, no main burner) cont. Trouble- shooting cont RESULTS If: then: replace the main valve. the meter does not read continuity, the meter does read continuity, check gas supply.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. PilOT PROBLEMS Trouble- shooting cont. The following are possible causes of pilot problems: 1. An open E.C.O. (high limit) will not allow the heater to relight. (See page 84).
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 SERVICE AND OPERATION cant. MAIN BURNER PROBLEMS Trouble- shooting cont. The following are possible causes of main burner problems: 1. Unlevel burner will cause yellow flames. 2. Burning at the orifice indicates main gas valve may not be fully closing.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS 75 PARTS LIST - 33 R 4 2 ~ 3 AEUEF VALVE ~ 1 .~~ -- - Q - 3511 21 I ~ r~ I~~ 22 ~..; ~ I 24 g! A_rccaas CLO- TYPO ~ -'TYPO - j;k T-.;- ~. -no-- j ~;-' ::; =o:Z--" ..,..,--- 5 , .,-.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK FPS-75 SERIES 230/231 THRU 232/233 Description Part Number Item 1 Anode , 180618-42 Baffle 2 Baffle, Flue ...,..",.",.,."."."... 182193 3 Flue Restrictor '.."'.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK PART INFORMATION CONTROL MODELS SPECIFICATION Fan Draws.75 amp, Turns at 3325 RPM Draws.75 amp, Turns at 3325 RPM Draws 1.8 amp, Turns at 3000 RPM FPS40-50 FPSE & FPD40 - 50 FPS75 Air Pressure Switch FPS40-50 FPSE & FPD40 - 50 FPS75 Closes at .
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK SERVICE CHECKLIST VI PROPER SEQUENCE OF OPERATION yes yes yes yes yes yes yes yes no no no no no no no no A.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK i SERVICE CHECKLIST cant. VII. SAFETY A. Gas yes yes yes yes yes no no no no no Does pilot flame prove before main burner ignites? Does damper blade fully open before ignition sequence occurs? Is burner cover plate in place? Is burner floor shield in place? Does liD lockout occur after 30 sec.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK QUESTIONS AND ANSWERS FPS MODELS What is the CFM of the blower? Q Maximum of 60 CFM A. Will the blower move more air through the unit than conventional venting and thereby cause less heat to be transferred into the water? Q No.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK QUESTIONS AND ANSWERS cant. Q Is there a maximum distance that the vent cap can terminate from the exterior wall? A.
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK ADDITIONAL INFORMATION If the inlet air damper does not open to provide dilution air, the PVC vent will sag due to excessive temperature. Propane units do not have a bypass in the gas solenoid valve.
&c @)c 0[fiJDcu:'~ A DIVISION OF A.O. SMITH CORPORATION 00 FOR ADDITIONAL INFORMATION CONTACT A.O. SMITH TECHNICAL INFORMATION DEPARTMENT AT 1-800-527 -1953.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté A.O. Smith fps50 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du A.O. Smith fps50 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation A.O. Smith fps50, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le A.O. Smith fps50 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le A.O. Smith fps50, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du A.O. Smith fps50.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le A.O. Smith fps50. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei A.O. Smith fps50 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.