Manuel d'utilisation / d'entretien du produit T874A-F du fabricant Honeywell
Aller à la page of 12
1 60-1165—6 Q674 Switch Positions Model System Fan A Heat-Auto-Cool Auto-On B Heat-Off-Cool Auto-On C Off-Auto Auto-On D None None E Off-Heat-Auto-Cool Auto-On G Off-Auto None T874A-F Multistage Thermostats/Q674A-E,G Subbases TRADELINE ® Installation Instructions for the Trained Service Technician.
2 60-1165—6 Fig. 1—Installation of subbase on outlet box. 2. Pull electrical wires through the cover plate (if use d) and subbase cable opening (Fig. 3). See Wiring the Subbase section before pulling any wires. IMPORTANT: Use 18 gauge, color-coded thermostat cable for proper wiring.
3 60-1165—6 3. Firmly tighten each terminal screw. 4. Fit wires as close as possible to the subbase. Push exc ess wire back into the hole. 5. Plug hole with nonflammable insulation to prevent drafts from affecting the thermostat. Fig. 5—Jumper RC and RH for single trans- former system.
4 60-1165—6 Fig. 8—T874A-D/Q674A in standard heating/cooling system. Fig. 9—T874C,D/Q674B in standard heating/cooling system with separate transformers for heating and cooling. H1 FALL L1 (HOT) L2 1 RH W1 W2 O G Y2 Y1 RC HEAT RELAY 2 HEAT RELAY 1 HEAT OFF COOL SYSTEM SWITCH H1 ANTICIPATOR C1 ANTICIPATOR AUTO ON FAN SWITCH 2 1 POWER SUPPLY.
5 60-1165—6 Fig. 10—T874D/Q674B in standard heating/cooling system with single transformer for heating and cooling. Exact replacement for York model no.
6 60-1165—6 Fig. 12—T874A,D,F/Q674D in standard heating/cooling system. Fig. 13—T874D/Q674E in standard heating/cooling system..
7 60-1165—6 Fig. 14—T874A-F/Q674G in standard heating/cooling system. Fig. 15—T874C/Q674B in standard application..
8 60-1165—6 Fig. 16—Typical Q674 terminal designations. The thermostat and subbase used determines the number of system components controlled. TEMPERATURE LEVER STOPS Some thermostats have factory-installed temperature lever locking screws (Fig. 17) and/or stop brackets (Fig.
9 60-1165—6 9. Firmly tighten the mounting screw. 10. If the HEAT and COOL levers are to be locked in place at a specific temperature, use the two insulated head screws supplied instead of the two adjustable lever stop brackets. CAUTION Do not use standard screws that provide metal-to- metal contact with the stop brackets.
10 60-1165—6 2. Move the system switch to AUTO or HEAT (if used) . 3. After one minute, read the ammeter and record the reading: Stage 1: __________ amperes. Stage 2: __________ amperes. NOTE: If equipment cycles too fast, set the indicator to a higher current rating, not more than one-half division at a time, and recheck cycle rate.
11 60-1165—6 Calibration THERMOSTAT T874 Thermostats are accurately calibrated at the factory. They do not have provision for field calibration. THERMOMETER The thermometer in the thermostat has been accurately calibrated at the factory. The thermometer should need ad- justment only if it has been dropped or shifted due to mishan- dling.
12 60-1165—6 www.honeywell.com/yourhome Automation and Control Solutions Honeywell International Inc. Honeywell Limited—Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Honeywell T874A-F c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Honeywell T874A-F - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Honeywell T874A-F, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Honeywell T874A-F va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Honeywell T874A-F, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Honeywell T874A-F.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Honeywell T874A-F. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Honeywell T874A-F ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.