Manuel d'utilisation / d'entretien du produit MS3780 du fabricant Honeywell
Aller à la page of 52
MS 378 0 Fusi on Omni/Single Li ne Scanner ™ User’s Guide.
Disclaimer Honeyw ell Internat ional Inc . (“ HII”) reserv es th e right t o make ch anges i n specificat ions and ot her i nform ation contai ned in t his do cument w ithout pr ior notice, and t he re ader should in all cases c onsult HII to deter mine w hether any such chang es have be en mad e.
ii T ABLE OF C ONTENTS Introducti on Product O verview ............................................................................................. 1 Scanner an d Accessor ies ..........................................................................
iii T ABLE OF C ONTENTS Troublesh ooting Gu ide ....................................................................................... 23 Design Spe cification s ........................................................................................
1 I NTRODUCTION The MS 3780 Fus ion ™ is a hand - held, omnidir ectional bar code scanner with optional single - line scanning c apabilities. It utilizes the pow erful Honyewell QuantumE s can engine to pro vide an outstanding scan performan c e on all standard 1D bar cod e symbol ogie s, i ncl udi ng GS1 D a taBar™ (RSS) .
2 I NTRODUCTION Scanner and A ccessories B ASIC K IT C OMPONENTS Part No. Descripti on MS3780 Fusion S canner 00 - 02 2 69 M S3780 User’s Guide * 00 - 02407 M etroSelect ™ * Guides al so available for download at www. hon ey well aidc .co m. Configurati on Guide * O PTION AL A CCES SO RIES Part No.
3 I NTRODUCTION Scanner and A ccessories O PTION AL A CCES SO RIES Part No. Descripti on MVC - 3MNC - N 7052 V oltage Conv erter Cable, ±12 VDC to +5.
4 I NTRODUCTION Scanner Components Figure 1 . Scanner Components I TE M N O . D ESCRIPTION 1 Re d Output W indow, Laser Aperture (S ee page 36 ) 2 Mode S elect Button (See page 13 ) 3 Beeper (S ee pag.
5 I NTRODUCTION Caution and Serial Number Labels Figure 2. Caution and Serial Labels Caution: To maintain compliance with applicable standards, all circuits connected to the scanner mu st meet the requirements for SELV (S afety E xtra L ow V oltage) according to EN/IEC 60950- 1.
6 I NTRODUCTION Maintenance Smudges and dirt on the unit' s window can inter fere with the unit's performa nce. If the window requires clean ing, use only a mild gla s s clean er containing no ammonia. W hen clean ing th e window , spray the clea ner onto a lint f ree, non - abrasive cl eaning cloth t hen gent ly w ipe the w indow clean.
7 I NSTALLATION RS232 or Light Pen 1. Turn off the host device. 2. Plug the m ale 10 - pin R J 45 end of the Pow erLink cable into the 10 - pin sock et on th e MS3780. 3. Connect th e 9 - pin female end of the PowerLink c able to the appro priate communicat ion port on the host devi ce.
8 I NSTALLATION RS485 o r O C I A 1. Turn off the host device. 2. Plug the m ale 10 - pin R J45 end of the MVC c able into t he 10 - pin sock et on th e MS3780.
9 I NSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the m ale 10 - pin R J45 end of the PowerLink c able into the 1 0 - pin socket on the M S3780. 3. Disconnect t he keyboard fro m the host device. 4. Connect th e “Y” end of the P owerLink cable to the keyboard and th e keyboar d port on the host PC.
10 I NSTALLATION Stand - A l one Keyboard 1. Turn off the host device. 2. Plug the m ale 10 - pin R J 45 end of the Pow erLink cable into the 10 - pin sock et on th e MS3780. 3. Connect th e other end of th e PowerLink cabl e to the keyboard port on the host device.
11 Figure 11 . I NSTALLATION Full Speed or Lo w Speed USB (Integrated) 1. Turn off the host device. 2. Plug the m ale 10 - pin R J45 end of the USB Pow erLink cable int o the 10 - pin sock et on th e MS3780. 3. Plug the ot her end of the U SB interface cable into the host device’s USB port.
12 I NSTALLATION EAS Deactivation S W 1 and S W 2 are th e switc h banks i nside the Checkpoi nt Device that set the deactivatio n range . T he follow ing is a li st of Checkpoint recommended sw itch bank settin gs.
13 S CANNER O PERATION The Scan Pat tern Mode Select Button There are tw o configurable s can pattern mod es available w ith the MS3780. • The pr imary sc an pattern m ode is the default scan pattern active when the scanner start s. By default, the primary sc an pattern is se t to all - scan - li nes for omnid irectional r eading.
14 S CANNER O PERATION How to Use CodeGate and t he Manual A cti vation Mode For illus tration p urposes the unit ’s scan pattern h as been set to single - l ine (menu r eading) mode . C ODE G A TE M ANUAL A CTI VATION M O DE * * This feature is not a default setting.
15 S CANNER O PERATION A udibl e Indicators When the M S3780 is in operat ion, it can prov ide audible fee dback. These sounds ind ic ate th e status of the scanner. E ight settings are available for the tone of th e beep (normal, six alternate to nes and no tone) .
16 S CANNER O PERATION Visual Indicator s There are fo ur LEDs locate d on the t op of th e MS3780. W he n the scanner is on, the flashing or constant il lumination of t he LEDs in dicates the stat us of the current scan and the scanner.
17 S CANN ER O PERATION Failure Mode Indi cators Both Blue LEDs Flashing with O ne Emitted Raz zberr y Tone This indica tes that the s canner has ex perienced a laser subs ystem failure. Return the un it to a Honey well author ized service ce nter for repai r.
18 S CANNER O PERATION Depth of Field Specifications* Normal Scan Zone Specificat ions are b ased on a 0.33 m m (13 mil ) bar code. Figure 19 . Normal Depth of Field * All specifi cations are su bject to ch ange without not ice.
19 S CANNER O PERATION Depth of Field Specifications* Reduced Scan Zone Specificat ions are b ased on a 0.33 m m (13 mil) bar code. Figure 20 . Reduced Depth of Field * All specifi cations are su bject to ch ange without not ice.
20 S CANNER O PERATION Depth of Field by B ar Code Element Width* Normal Scan Zone M INIMU M B AR C ODE E LE MENT W IDTH A B C D E F mm .13 .15 .19 .25 . 33 .66 mils 5. 2 5.7 7.5 10 13 26 Figure 21 . Normal Scan Zone by Bar Code Element Width * All specifi cations are su bject to ch ange without not ice.
21 S CANNER O PERATION Depth of Field by B ar Code Element Wi dt h* Reduced Scan Zone M INIMU M B AR C ODE E LE MENT W IDTH A B C D E F mm .13 .15 .19 .25 . 33 .66 mils 5. 2 5.7 7.5 10 13 26 Figure 22 . Reduced S can Zone by B ar Code Element Width * All specifi cations are su bject to ch ange without not ice.
22 S CANNER O PERATION IR Activation Range* Fusion’s de fault power save mode † is Laser O ff then M otor Off Delayed . This pow er save mode turns the laser off after five mi nutes of non - us e. The motor w ill turn off aft er twenty - five minutes of non - use .
23 T ROUBL ESHOOT ING G UIDE The follow ing guide is for reference purposes only. C ontact a Honey we l l representa tive at to preserv e the limited w arranty terms on page 39 . Symptoms Possible Cau se(s) Solution All Interfa ces The unit h as no LEDs, beeper or motor s pi n.
24 T ROUBL ESHOOT ING G UIDE Symptoms Possible Cau se(s) Solution All Interfa ces The unit scans a ba r code, but locks up after the first scan ( the white LED stays o n ). The scanner is configure d to support some form of host handshakin g but is not receiving th e signal.
25 T ROU BLESHOOTI NG G UIDE Symptoms Possible Cau se(s) Solution All Interfa ces During pow er up the un it beeps 3 tim es. There is a non - volati le RAM failure. Contact a serv ice repr esentat ive. During pow er up the un it razze s continuous ly.
26 T ROUBL ESHOOT ING G UIDE Symptoms Possible Cau se(s) Solution RS232 Onl y The host is receiving d ata but the da ta does not look correct. The scanner and host may not be configured for the sa m e inter face. Check that the scanner and t he host are configur ed for the s ame interface.
27 D ESIGN S PECIFICATIONS MS3780 Operational Normal Depth of Field: 25 mm - 280 mm (1 "- 11 " ) 0.33 mm (13 mi l) bar code Reduced Depth of Field: 25 mm - 150 mm (1 "- 6" ) Omni Scan Scan Speed: 1333 scan lines per second No. of Scan Lines: 20 Single -L ine Scan Speed: 67 scan lines per second No.
28 D ESIGN S PECIFICATIONS MS3780 E lectrical Voltage S upply: 5VDC ± 0.25V Operating Power: 1.375 W Standby Power: 1.0 W Operating Current: 275 mA typical at 5VDC Standby Current: 200 mA typical at 5VDC DC Transformers: Clas s II; 5.2VDC @ 1 A For regulatory complianc e information , see pages 36 - 38 .
29 A PPLICATIONS AND P ROTOC OLS The model nu mber on each s canner inc ludes the scanner number and fac tory default com munications prot ocol. S CANNER V ERSION I DENTIFIER I NTERFACE MS3780 9 OCIA .
30 C ONFIGURATION M ODES The MS 3780 Series scanner h as three modes o f confi guratio n. • Bar Codes The MS 3780 can be co nfigured by scann ing the bar code s included in th e Single - Lin e Configur ation Guide or the Su pple m ental Co nfiguration G uide .
31 U PGRADING THE F I R MW A R E The MS 3780 Fus ion is part of Honey well’s line of s canners w ith flash upgradeab le firmw are. The upgrade process require s a new firmw are file supplied to the customer by a customer serv ice repre s entativ e and Honeyw ell’s Metr oSet 2 software .
32 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections The MS 3780 scanner i nterfaces ter minate to a 10 - pi n modul ar socket. The seria l number la bel indicat es the inter face enab led when the scan ner is shipped fro m the factory. Figure 24 .
33 S CANNER AND C ABLE T ERMINATIONS Figure 25 . MS3780 - 11 RS485 MS3780 - 9 OCIA Pin Function Pin Function 1 Ground 1 Ground 2 RS232 Tr ansmit Out put 2 RS232 Tr ansmit Out put 3 RS232 Receiv e .
34 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) RS232 Pow erLink Cable 53-53000 x-3 Pin Function 1 Shield Gr ound 2 RS232 Tr ansmit Out put 3 RS232 Receiv e Input 4 DTR .
35 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge PowerLink Cable 53 - 53002x -3 Pin Function 5- Pin DIN, Fem ale 1 Keyboard Cl ock 2 Keyboard D ata 3 No Co.
36 R EGULA TOR Y C OMPLIANCE Safety ITE Equipment IEC 60950 - 1 Sec ond Edition , EN 60950 -1 Second Edit ion Laser Laser Class 1: IEC 60825 - 1: Second E dition, 2007 , EN 60825 -1: Second Edit ion, 2007 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No.
37 R EGULA TOR Y C OMPLIANCE Atten zione L’utilizzo di sist emi di controllo, di regolazioni o di pr ocedi menti diversi da quelli descritti nel presente Manual e può provocare delle esposizioni a r aggi laser rischio se. Il cliente non deve assoluta m ente ten tare di r iparare egli stesso lo scanne r laser.
38 R EGULA TOR Y C OMPLIANCE EMC Changes or modificati ons not expressly approved by the party responsible for com pli ance could void the user’s authority to operate the equipment. Warnung! Dies ist ein e Einrichtung der Kla sse A. Diese Einrichtung ka nn im Wohnberei ch Funkstörungen v erursachen.
39 L IMITED W ARRAN TY Honeyw ell International Inc . ("HII") w arrants its products and opti onal accessorie s to be f ree from defects in materia ls and workma nship and to conform t o HII’s p ublished specifi cations ap plicable to th e product s purchas ed at the time of shipmen t.
40 L IMITED W ARRAN TY All provisions of this Lim ited Warrant y are s eparat e and sev erable, which mean s that if any prov ision is he l d invalid and unenforceab l e, such d etermination sha ll not affect the validity of e nforceability of the other prov isions hereof.
41 I NDEX A AC ....................................... 2, 7 – 11 Access ories ............................... 2, 3 Adapter .......................................... 9 Audible In dicator .. 15– 17, 23– 26, 31 B Bar Code ....... 15– 17, 23– 26, 27, 30 Bar W idth .
42 I NDEX M Maintenanc e .................................. 6 Manual ............................... 2, 15, 29 Meteor ......................................... 31 Metr oSelect ................................ . 30 Metr oSet2 ..........................
43 C USTOMER S UPPORT Technical Assistance If you ne ed assist ance installin g or troubleshooti ng your devi ce, please contact us by usin g one of the method s below: Knowledge B ase: www.hsmknowledgeba se. com Our Know ledge Base provide s thousands of i mm ediate s olutions.
.
.
.
.
Honeyw ell Scanning and M obility 9 680 Old Bai les Road Fort M il l, SC 29707 www .honey wellaidc. com 00 - 02269 Rev G 11 /12.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Honeywell MS3780 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Honeywell MS3780 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Honeywell MS3780, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Honeywell MS3780 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Honeywell MS3780, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Honeywell MS3780.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Honeywell MS3780. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Honeywell MS3780 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.