F300E Electronic Air Cleaner PRODUCT DA T A ® U.S. Registered Trademark Copyright © 2000 Honeywell • All Rights Reserved APPLICA TION The F300E Electronic Air Cleaner is mounted in the retur n air duct of a forced air heating, cooling, or v entilating system.
F300E ELECTRONIC AIR CLEANER 68-0240-1 2 SPECIFICA TIONS IMPORT ANT The specifications giv en in this publication do not include nor mal manuf acturing toler ances .
F300E ELECTR ONIC AIR CLEANER 68-0240-1 3 Fig. 1. Air c leaner efficiency and pressure drop at v arious airflow rates. Weight: See T able 2. Dimensions: See Fig. 2. Underwriters Laboratories Inc. Listed: File No . E30954. Accessories: 203365A Conv ersion Kit for changing 120V , 60 Hz pow er supply to 240V , 60 Hz or 220/240, 50 Hz.
F300E ELECTRONIC AIR CLEANER 68-0240-1 4 Fig. 2. Installation dimensions of Electr onic Air Cleaner in in. (mm). PLANNING THE INST ALLA TION Application The F300E Electronic Air Cleaner is used in a forced air heating, cooling, or ventilating system. It removes airborne par ticles from the air circulated through it.
F300E ELECTR ONIC AIR CLEANER 68-0240-1 5 1. Mount it as far as possib le upstream from the air cleaner . 2. Install a standard disposable furnace filter between the humidifier and the air cleaner to trap water droplets and hard water salts . 3. F requently clean the air cleaner to prev ent a hard water salt b uildup.
F300E ELECTRONIC AIR CLEANER 68-0240-1 6 Fig. 3. Mounting positions with v ariety of furnace installations. Determine Duct Design Requirements The air cleaner is adaptable to all ne w or existing f orced air heating, cooling and ventilating systems used in residential applications.
F300E ELECTR ONIC AIR CLEANER 68-0240-1 7 ❑ Place bloc ks under the cabinet so the unit is firmly suppor ted and lev el. The 5/8 in. (16 mm) mounting foot on the cabinet hinge plate provides the minimum clear ance required f or the access door hinge.
F300E ELECTRONIC AIR CLEANER 68-0240-1 8 Fig. 7. Connect ductw ork to air cleaner . Note turning vanes. Locking plier s hold duct to air cleaner cabinet during installation. Install Optional W8600F Air Cleaner Monitor The W8600F Air Cleaner Monitor is an option a v ailable for use with the F300E.
F300E ELECTR ONIC AIR CLEANER 68-0240-1 9 Select W ash Frequency Use the W8600F DIP switches to prog ram the time between SER VICE indications. Be sure to select the setting according to the conditions of the home.
F300E ELECTRONIC AIR CLEANER 68-0240-1 10 10. Plug the driver board assemb ly into the J1 power supply connector . 11. Replace the power supply bo x cov er .
F300E ELECTR ONIC AIR CLEANER 68-0240-1 11 Fig. 16. P osition of cell ke y determines orientation of cell (arro w on key must point do wnstream). 4. Tighten the screw into the ne w hole. 5. Inser t the electronic cell. The ioniz er section will now be on the air-entering (upstream) side of the cabinet.
F300E ELECTRONIC AIR CLEANER 68-0240-1 12 P3 P4 P1 P2 J3 BLACK W4 W2 W1 W3 AIRFLOW SWITCH BOARD ORANGE GRAY VIOLET BLACK 1 INTERLOCK SWITCH. 2 SHORTING BAR. 3 AIRFLOW SWITCH DISABLE JUMPER. 4 OPTIONAL W8600F AIR CLEANER MONITOR. DRIVER BOARD AND CABLE PROVIDED WITH W8600F.
F300E ELECTR ONIC AIR CLEANER 68-0240-1 13 • Outside air , if used, is mix ed with retur n air or heated, as necessary , bef ore it can reach the air cleaner . • Airflow arro ws on the electronic cell point downstream. • Prefilter is on the upstream side of the cell.
F300E ELECTRONIC AIR CLEANER 68-0240-1 14 NO TE : T o let the heating or air conditioning system operate normally while the cell(s) are being washed, simply turn off the air cleaner switch. V acuum the prefilter or brush, or soak it in a tub . Do not wash the prefilter in the dishwasher or car w ash.
F300E ELECTR ONIC AIR CLEANER 68-0240-1 15 Fig. 23. Replacing an ionizer wire . COLLECTOR TERMINAL COLLECTOR TERMINAL IONIZER TERMINAL M6155 5. Rinse the cell(s) and prefilter(s) with a hard spra y of very hot water; rinse the tub clean, then fill the tub with clean hot water and soak f or 5 to 15 minutes.
F300E ELECTRONIC AIR CLEANER 68-0240-1 16 Modification to Reduce Ozone Odor W ARNING Electric Shock Hazar d. Can cause personal injury . Alwa ys disconnect power and open the access door before opening the po wer supply cov er. The electronic air cleaner generates a small amount of ozone in normal operation.
F300E ELECTR ONIC AIR CLEANER 68-0240-1 17 Fig. 25. Move J5 shor ting bar to reduce ozone production about 20 to 25 percent. P3 P4 P1 P2 M15099 J3 J4 J5 SHUNT IN OZONE REDUCTION POSITION J5 IN NORMAL .
F300E ELECTRONIC AIR CLEANER 68-0240-1 18 REPLACEMENT PARTS/EXPLODED VIEW Nominal Return Air Opening No. Description 16 x 20 in. (406 x 508 mm) 16 x 25 in.
F300E ELECTR ONIC AIR CLEANER 68-0240-1 19 Fig. 27. Components of the Electronic Air Cleaner (2-cell model shown). M14740 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20.
F300E ELECTRONIC AIR CLEANER 68-0240-1 20 Parts and Accessories Not Illustrated ELECTRICAL TROUBLESHOOTING W ARNING Electric Shock Hazar d. Can cause personal injury or equipment damage. The follo wing procedures expose hazardous liv e par ts. Disconnect from power betw een checks and proceed carefully .
F300E ELECTR ONIC AIR CLEANER 68-0240-1 21 TR OUBLE SHOOTING AIR CLEANERS WITH PERFORMANCE INDICA T OR. Fig. 28. T roub leshooting air cleaner s. MAKE SURE ELECTRONIC CELLS ARE CLEAN, DRY, AND CORRECTLY INSTALLED. MAKE SURE PREFILTERS ARE IN CABINET SLOT FARTHEST FROM FURNACE OR AIR HANDLER.
F300E ELECTRONIC AIR CLEANER 68-0240-1 22.
F300E ELECTR ONIC AIR CLEANER 68-0240-1 23 YEAR ELECTRONIC AIR CLEANER WASH REMINDER SCHEDULE , M982A JF M A M J J AS O N D INSTALLATION DATE:.
Home and Building Control Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 68-0240-1 G.H. Rev . 9-00 Home and Building Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Honeywell F300E c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Honeywell F300E - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Honeywell F300E, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Honeywell F300E va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Honeywell F300E, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Honeywell F300E.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Honeywell F300E. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Honeywell F300E ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.