Manuel d'utilisation / d'entretien du produit DR90 du fabricant Honeywell
Aller à la page of 16
D C A B F G 1 G 2 G 3 G 4 E T rueDR Y™ DR90 (1) 10-in. duct collar (1) 6-in. duct collar (1) MERV II Filter (1) Filter Door (1) Installation Guide Prestige Comfort System (wir eless) T ruelAQ H8908 Manual Dehumidistat VisionPRO IAQ control (included with DR90VPIAQ) T ools r equired to install T rueDR Y DR90 3/8-in.
Installation Checklist Included in This Box A T rueDR Y™ DR90 (1) B 10-in. duct collar (2) C 6-in. duct collar (1) D MER V II Filter (1) E Filter Door (1) F Installation Guide Control Options (Sold .
T rueDR Y TM NEED HELP? For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-fr ee at 1-800-468-1502. Read and save these instructions. ® U.S. Registered T rademark. Patents pending. Copyright © 2010 Honeywell Inter national Inc.
AbouttheT rueDR Y™DR90Dehumidier The Honeywell T rueDRY DR90 ensures the home is maintained at proper humidity levels through its high performance and efficiency . Benefits • Removes upto 90pints ofwater per dayfromthe indoor air .
VisionPRO IAQ T otal Comfort System (YTH9421C1010) • Controlsboth heating/coolingand dehumidification. • Sensor includedfor displayingoutdoor temperature. • Intuitive userinterface foreasy 7-daytemperature pr ogramming.
Specications Install T rueDR Y DR90 according to National Electric Codes. Dimensions in inches and (mm): Product weight: 92.2 lbs. Shipping weight: 102 lbs. Shipping dimensions: 21.5 in. H x 18.5 in. W x 40.2 in. L Media Filter: MERV 11, 13.75 in. H x 13.
Install to Fit Y our Application T rueDry DR90 Dehumidication System 69-2407—01 5 Flex duct is r ecommended in connecting to the T rueDRY DR90 collars to reduce vibration noise. M24745 Electrical r equirements: 115 V AC outlet. Ground fault interrupter (GFI) recommended.
Ideal when… • Drying aspecific ar ea ofthe house. • Running withA/C operationrequires backdraft damper on the exhaust port to minimizebackdraft whenT rueDR Y DR90 is not on but A/C is.
T erminal Description * NOTE: The outer screws on the terminal block secure the block to the chassis. They ar e not used for wiring. A wiring terminal block is located on the side panel of the T rueDR Y unit.
Wiring (continued) T rueDry DR90 Dehumidication System 69-2407—01 8 Follow this diagram for ducted operation with an external humidity control. TrueDRY HV AC MECHANICAL DEHUMIDIS TA T THERMOST AT G Y W RR c G Y W R C M29840 DRY CONT ACTS + + FA N C DPDT RELA Y, 2.
Wiring (continued) Follow this diagram if using T rueDRY DR90 with a powered dehumidistat such as T rueIAQ (DG115EZIQ). HV AC THERMOST AT G Y W RR c M29842 IF A THERMOST AT OTHER THAN A TH51 10, TH5220, TH5320, TH61 10, TH6220, TH6320, TH81 10, TH8320, OR TH8321 IS USED, A RELA Y MA Y BE REQUIRED TO ISOL AT E THE G WIRE.
Cleaning Apply power to T rueDR Y DR90. T urn the humidity control to a low RH% level to initiate a dehumidification call. Confirm that the T rueDR Y DR90 compressor and fan turn on. The furnace blower will also tur n on to circulate air . This will take up to two minutes.
T rueDry DR90 Dehumidication System 69-2407—01 11 T echnical Description T rueDRY DR90 uses a refrigeration system similar to an air conditioner to remove heat and moistur e fr om incoming air and add heat to the air that is discharged. Hot, high-pr essure refrigerant gas is routed fr om the compressor to the condenser coil.
T r oubleshooting (continued) Problem Recommended T roubleshooting Steps Fan does not run with ventilation activated. Compressor runs briefly but cycles on & off with humidity contr ol tur ned to ON. 1. Loose connection in fan cir cuit. 2. Obstruction prevents fan r otation.
Parts List Figure Reference Description Part Number 1 T rueDRY with no controls DR90A1000 2 T rueDR Y with VisionPRO IAQ Contr ol DR90VPIAQ 3 Pr estige Comfort System YTHX9321R5003 4 VisionPRO IAQ T o.
Honeywell International Inc. 1985 Douglas Drive North Golden V alley , MN 55422 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive T oronto, Ontario M1V 4Z9 http://yourhome.honeywell.com Automation and Control Solutions ® U.S. Register ed T rademark.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Honeywell DR90 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Honeywell DR90 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Honeywell DR90, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Honeywell DR90 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Honeywell DR90, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Honeywell DR90.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Honeywell DR90. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Honeywell DR90 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.