PRODUCT DA T A ® U.S. Registered Trademark Copyright © 1997 Honeywell Inc. • All Rights Reserved D896 Automatic V ent Damper GENERAL D896 Automatic V ent Dampers are used with atmospheric type, gas-fired equipment to reduce home heating losses b y closing off the vent betw een heat cycles.
D896 A UT OMA TIC VENT D AMPER 68-0186 2 ORDERING INFORMA TION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distr ibutor , ref er to the TRADELINE® Catalog or price sheets for complete ordering number .
D896 A UT OMA TIC VENT D AMPER 68-0186 3 NO TE: A minimum of a 30 V A transf or mer must be used when D896 is installed with S86/S8600/S8610/ S8620. Electrical Connections: F our-wire plug receptacle. Thermostat Anticipator Setting: 0.13A. Operating Times: Appro ximate Damper Opening Time: 30 seconds.
D896 A UT OMA TIC VENT D AMPER 68-0186 4 IMPORT ANT 1. The atmospheric draft hood outlet area must be smaller or equal to the inlet area of the damper assembly . 2. If a second gas valv e needs to be installed, refer to the gas valv e manufacturer instructions f or the procedure.
D896 A UT OMA TIC VENT D AMPER 68-0186 5 Fig. 3. Installing D896 V ent Damper . IMPORT ANT Ne ver mount the vent damper with the motor actuator abov e or below the vent. Do not install the damper blade plug if the v ent damper is installed on a system with a continuous or standing pilot.
D896 A UT OMA TIC VENT D AMPER 68-0186 6 Fig. 5. D896 with co ver off. Honeywell D892/D896 Wires Honeywell D80B Wires Johnson Q35 Wires EFFIKAL RVG Wires Yellow Orange Green 1 Orange Blue and Red Whit.
D896 A UT OMA TIC VENT D AMPER 68-0186 7 MV MV/PV PV GND (BURNER) 24V GND 24V SPARK S8600F, H, M; S8610F,H POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. REMOVE PLUG ONLY IF USING VENT DAMPER. FUSE BLOWS ON STARTUP WHEN PLUG IS REMOVED; THEN MODULE OPERATES ONLY WHEN VENT DAMPER IS CONNECTED.
D896 A UT OMA TIC VENT D AMPER 68-0186 8 Fig. 10. Snap-Tite™ Bo x Connector release. Checkout Heating 1. Tu rn on the po wer supply . 2. If using a thermostat, set the heat anticipator at 0.13A. 3. Set the thermostat or controller to 10 ° F (6 ° C) above the room temperature to call f or heat.
D896 A UT OMA TIC VENT D AMPER 68-0186 9 Thermostat Setting Symptom Possible Cause Action Set thermostat 10°F above room temperature to call for heat. No response from D896. Incorrect wiring or blown fuse. • Check the circuit breaker or fuse and, if necessary, reset or replace.
D896 A UT OMA TIC VENT D AMPER 68-0186 10 ANSI ST ANDARDS EXHIBIT A Procedure For Saf ety Inspection of an Existing Appliance Installation The f ollowing procedure is intended as a guide to aid in determining that an appliance is proper ly installed and is in a safe condition f or continuing use.
D896 A UT OMA TIC VENT D AMPER 68-0186 11 EXHIBIT B Procedure f or Installing Electrically Operated Automatic Vent Damper De vices on Existing Appliances This procedure is intended as a guide to aid in safely installing an electrically operated or mechanically actuated automatic vent damper de vice on an existing appliance .
D896 A UT OMA TIC VENT D AMPER 68-0186 12 Honeywell Europe S.A. 3 Avenue du Bourget B-1140 Brussels Belgium Honeywell Asia Pacific Inc. Room 3213-3225 Sun Hung Kai Centre No.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Honeywell D896 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Honeywell D896 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Honeywell D896, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Honeywell D896 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Honeywell D896, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Honeywell D896.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Honeywell D896. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Honeywell D896 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.