Manuel d'utilisation / d'entretien du produit HGFD65 ML-126418 du fabricant Hobart
Aller à la page of 36
701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.hobartcorp.com HOBAR T HGF , HGD AND HGC SERIES GAS FR YERS WITH OR WITHOUT FILTER-IN-A-DRAWER MODELS HGF35 ML-126994 HGF45 ML-126995 HGF65 M.
– 2 – IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED.
– 3 – TABLE OF CONTENTS GENERAL ............................................................................................................................................ 5 SPECIFICATIONS .........................................................
– 4 – TABLE OF CONTENTS (cont.) HGFC SERIES .................................................................................................................................. 2 1 CONTROLS ...........................................................
– 5 – Installation, Operation and Care of MODELS HGF, HGD and HGC SERIES GAS FRYERS SAVE THESE INSTRUCTIONS GENERAL Hobart HGF, HGD and HGC Series Gas Fryers are produced with quality workmanship and material. Proper installation, usage and maintenance of your fryer will result in many years of satisfactory performance.
– 6 – OPTIONS AND FEATURES • Stainless Steel Tank (Standard) • Basket Lift with Timer (D and C series) • Tri-, Twin- or Single-Basket (D and C series) • Manual Pilot or Electronic Ignition.
– 7 – 3 Cabinets in Battery Filter Filter Filter Fryer Fryer Fryer AB C Fryer Dump Fryer A BC Fryer Fryer Dump AB C Filter A B C Dump Fryer Fryer 4 Cabinets in Battery (For 35 and 45 Only) AB C D .
– 8 – HGF SERIES FRYMATE (Dump Station) Model HGFO Frymate Dump Station can be configured in a battery with fryers 15 1 / 2 " (39 cm) or 21" (53 cm) in width. Frymate provides a final prep area where excess oil drains away and product is seasoned, packaged and kept ready for sale.
– 9 – INSTALLATION Before installing the fryer, verify that the type of gas (natural or propane) agrees with the specifications on the fryer data plate, which is located on the inside of the door panel. Ensure the fryer is configured for the proper elevation.
– 10 – LOCATION The equipment area must be kept free and clear of combustible substances. Minimum clearance from combustible construction is 6" (15 cm) from the sides and 6" (15 cm) from the back of the fryer. Minimum clearance from noncombustible construction is 0" from the sides and 0" from the back.
– 11 – ASSEMBLY When installed, the fryer must be restrained to prevent tipping to avoid the splashing of hot liquid. The means of restraint may be the manner of installation, such as connection to a battery of appliances or installing the fryer in an alcove, or by separate means, such as adequate ties.
– 12 – GAS CONNECTIONS CAUTION: Al l g a s s u p pl y c onnections and any pipe joint compound must be resistant to the action of propane gases. The gas inlet is located on the lower right rear of the fryer. Codes require that a gas shutoff valve be installed in the gas line ahead of the fryer.
– 13 – LEVELING FRYER 1 . Place a spirit level on top of the fryer after gas connections have been made. 2 . Adjust the legs to ensure that the fryer is level front-to-back and side-to side in the final installed position. FLUE CONNECTIONS The fryer must be located under a hood with adequate connection to an exhaust duct.
– 14 – OPERA TION WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT FRYING COMPOUND CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL FRYING COMPOUND FROM THE TANK.
– 15 – LIGHTING INSTRUCTIONS FOR HGF FRYER WITH MANUAL PILOT IGNITION NOTE: HGF fryer is only available with manual ignition. CAUTION: Be fo r e t u rning the burners on, the fry tank must be filled with liquid or melted shortening. 1 . Turn the thermostat OFF.
– 16 – STARTUP WITH ELECTRONIC IGNITION (HGFD & HGFC(F) SERIES) CAUTION: Be fo r e t u rning the burners on, the fry tank must be filled with liquid or melted shortening. 1 . Plug the power cord into an appropriate grounded receptacle and turn the main gas valve on.
– 17 – CONTROL DESCRIPTION Power switch; for turning the fryer on or off. For cleaning purposes when the fryer is filled with water. Tem- perature is maintained at approximately 192 ° F (89 ° C). For entering and exiting the program mode. For scrolling through program parameters.
– 18 – PROGRAMMING Temperature, time, energy source and other parameters must be set before operating. Once these parameters are set, the fryer can be operated at the touch of a button. Press to enter the program mode and scroll through the parameters.
– 19 – Melt Options (HGD Series) When using solid shortening in the fryer, the CY S (solid shortening) option must be used. Solid shortening must be gently warmed to a liquid state before heating to frying temperatures. Melting solid shortening without using this option will damage the fry tank and scorch the shortening.
– 20 – USING THE FRYER (After Startup) Models Without Basket Lift Option 1 . Load the fry basket(s); do not overfill. See Recommended Basket Capacities on page 30. 2 . Carefully lower basket(s) into shortening. 3 . Press to start the left timer. Press to start the right timer.
– 21 – HGFC(F) SERIES CONTROLS HGFC(F) Series Fryers have a microprocessor (computer) thermostat and timer. Control Guide Initiates program cooking cycles for units with or without basketlifts.
– 22 – PARAMETER STEPS LEFT DISPLAY RIG HT DI SPLAY Press SELECT OPTIONS Press DEGREES F or C F or C Press to select Fahrenheit or Celsius. DEGREES F or C F or C Press when complete. PROGRAM Press SELECT OPTIONS Press SET PASS NEW PASS Press to select NO PASS.
– 23 – Programming Guide (cont.) *Recovery - During a cold start, the controller measures the time the fryer takes to heat from 200 ° F to 250 ° F (93 ° C to 121 ° C) and compares it with factory default values.
– 24 – Melt Options When using solid shortening in the fryer, the SOLID melt option must be used. Solid shortening must be gently warmed to a liquid state before heating to frying temperatures. Melting solid shortening without using this option will damage the fry tank and scorch the shortening.
– 25 – TEMPERATURE AND TIME PROGRAMMING Temperature 1 . Press to enter program mode. PROGRAM is displayed in the window. 2 . Press to enter temperature mode. 000 ° F and TEMP are displayed in the window. 3 . Press through to enter desired fry temperature.
– 26 – Timers through : 1 . Press and enter the program mode. PROGRAM is displayed in the window. 2 . Press . The LED's on timers through are lit and SELECT PRODUCT is displayed in the window. 3. To select a timer, press one of the lit timer numbers; CK# 00:00 and TIME are displayed in the window.
– 27 – Setting Advanced Time Features 1 . Press and enter the program mode. 2 . Press for timers through , or press for timers through . The LEDs are lit on the timers available for programming, and SELECT PRODUCT is displayed in the window. 3 . Select a timer; the programmed time is displayed in the window.
– 28 – Time Programming Quick Chart Press to enter the program mode Press for timers to Press for timers to Select a Timer Press t o continue Set HOLD Time Select COMP or STRAIGHT Press Press Set .
– 29 – USING THE FRYER (After Startup) Models Without Basket Lift Option 1 . Load the fry basket(s); do not overfill. Refer to frying (All Models). 2 . Carefully lower basket(s) into shortening. 3 . Press the desired program number to select the product to be timed.
– 30 – FRYING GUIDELINES (All Models) • Heat shortening to set temperature. • Fry pieces of product that are about the same size together. • Drain or wipe dry raw or wet foods to minimize splatter when lowering into the hot shortening. • Keep shortening between the MIN and MAX lines.
– 31 – DAILY FILTERING WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. Filtering Guidelines (All Models) • Stand alone fryers are available in filter-ready and non-filter-ready versions. • Battery interplumbing is available only on fryers equipped with Filter-In-A-Drawer.
– 32 – Battery Interplumbing (Available Only on Filter-In-A-Drawer Models) A battery of fryers equipped with optional interplumbing connects the fry tanks to a common drain. Each tank has an individual drain valve. Only one tank can be filtered at a time.
– 33 – CLEANING WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. DAILY • Clean all exterior surfaces of your fryer at least once daily. • Use a damp cloth with warm water and a mild soap or detergent.
– 34 – 10. Drain the tank. 11. Rinse the tank thoroughly with clear, hot water (all traces of cleaner must be removed). 12. Dry the tank thoroughly. 13. Close the drain valve and add shortening. 14. Shortening level should be between the MIN and MAX lines.
– 35 – TROUBLESHOOTING GUIDE SYMPTOM No power when switch is turned on. Fryer will not heat. Fryer continues to heat. Fryer heats, but will not reach desired temperature. Fryer stops heating during operation. POSSIBLE CAUSES / SOLUTIONS Tripped breaker; fuse blown / Verify fryer is plugged in and outlet has power.
– 36 – FORM 35614 (February 2004) PRINTED IN U.S.A. ALARMS AND ERROR MESSAGES (HGD and HGC Series) Pilot Out - If the pilot is out, the control displays the following message: (Electronic ignition.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Hobart HGFD65 ML-126418 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Hobart HGFD65 ML-126418 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Hobart HGFD65 ML-126418, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Hobart HGFD65 ML-126418 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Hobart HGFD65 ML-126418, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Hobart HGFD65 ML-126418.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Hobart HGFD65 ML-126418. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Hobart HGFD65 ML-126418 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.