Features Novel exterior Excellent selected material, compact structure, arc streamline, simple line, luxurious and elegant, novel design, representing international prevalent trend.
.
Safety Notice 2 ! ! WARNING: CAUTION: Operations displaying this symbol may result in fatal injury. Operations displaying this symbol may result in serious injury. A. Instructions for installation B. Instructions for operation Installation only by authorized professionals through local distributors.
3 Avoid unnecessarily plugging and unplugging the appliance. Be sure that the power plug is clean and completely inserted to the socket. The appliance must only be used for room air conditioning. Never operate the appliance with wet hand. Keep plants or pets away from the air source.
Keep the room well ventilated, especially in rooms where burners are used. Disconnect the appliance when cleaning. Unplug the appliance when operation of the appliance stops. Make sure that fan stops before cleaning. Keep gas burners away from moving air from the appliance.
Components Introduction Air filter Indoor unit sensor(inside) Switch button Power plug Air outlet Impeller (left-right adjustment) Impeller (up-down adjustment) Air inlet Front cover INDOOR .
Components Introduction 6 POWER HI-POWER TIMER OPERATING INDOOR UNIT DISPLAY P ANEL ON/OFF Each part stands for: 1. Power indicator illuminating means the appliance in operating condition. 2. Timer indicator illuminating means the appliance in timer or sleep condition.
Components Introduction REMOTE CONTROL UNIT A A T .SETTING T .SETTING C A A HOUR ON OFF H.P. ON/OFF TEMP. SLEEP FLAP ON .
Components Introduction 8 HOW TO USE REMOTE CONTROL UNIT Install the battery 1 2 3 RESET button Sliding cover After replacement of batteries, the LCD on the remote control unit will display the status. 1. Press the two sides of the cover of the battery component and slide it downward and remove.
Operation Manual PREPARA TION BEFORE RUNNING Raise the front cover, and then install the air filter . MANUAL OPERATION (COOLING, DEHUMIDIFICA TION, FAN) Basic operation 1.Before running the appliance, press the "MODE" for selection one mode of the dehumidification, cooling and fan.
Operation Manual AUTO RUN Basic operation 1. Press the "MODE" button for selection of the "AUTO" function for automatic cessation of the appliance. 2. Press the "ON/OFF" button and the appliance is then set in automatic mode.
FLAP Operation Manual FAN SPEED AND DIRECTION ADJUSTMENT Basic operation When the appliance works, press "FAN/MUTE" change airflow speed. Press "FAN/MUTE" each time, indoor unit fan speed can be altered among , , , .
Operation Manual TIMER SWITCH ON/OFF Postponed Start Setting The appliance will start operating after the period set by the timer. When the appliance is set in the "Cooling" mode, a desired temperature will be reached after a desired set time (the reservation function).
C A A T .SETTING T .SETTING Operation Manual SLEEP SETTING MODE/HI-POWER OPERATION/AIR FRESHING Hi-power operation The appliance set in this mode will produce lower temperature air than ordinary condition. This function can make you feel comfortable rapidly in summer.
Maintenance 2 2 1 1 ! CAUTION Cuts and abrasions may result from contact with the sharp components inside the appliance. Clean the air filter once very two weeks. 1. Cleaning of indoor unit Wipe the indoor unit with a dry soft cloth damped in 40 ℃ water.
Maintenance 4. Cleaning and replacement of air fresh filter Raise the front cover and take out the air filter. T ake out the dirty air fresh filter from the air filter.
Wise Operation Blockage of the air inlet or outlet may reduce the cooling capacity of the appliance. Cooling capacity can be reduced by accumulated dirt on the air filter. Clean the air filter when noise is heard or water drops accumulate at the outlet.
Trouble S hooting Failure of airflow conversion Airflow cannot be altered when the dehumidification are started. Postponed operation The safety function postpones 3 or 5 minutes before operation after the appliance is connected to the power supply.
Trouble S hooting Make sure any of the following circumstances occurs: Failure of Operation Failure of Desired Cooling Capacity Power failure Operation of the appliance will be recovered after failure of power supply.
Trouble S hooting Contact the after-sales service for repair should any of the following events occur (see the Warranty Card). Strange sound Water leakage from indoor unit Loosed or corroded.
Technical Tables and Diagrams O 1. PERMITTED AMBIENT TEMPERATURE FOR THE AIR CONDITIONER IS AS FOLLOWING: +18~+43 C(GB/T 7725-1996). 3. REFRIGERANT FLOW DIAGRAM KF-5002GWE AC, 220V- 220V 50Hz 1.92 5.0kW 3 750m /h R22/1.85kg 13.0kg/54.0kg 。 8m/80 230V kW ~ 3 2.
Technical Tables and Diagrams 4. ELECTRICAL WIRING DIAGRAM FAN MOTOR 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 123 1 2 1 2 1 2 1 2 1 ~ 7 1 ~ 7 135 135 123 1 2 1 2 1 2 1 2 1 2 1 2 ROOM COIL SU COM CM FLAP1 FLAP2 FM PULSE IN SW PRY SEC 0 1 2 3 4 5 21 INDOOR UNIT POWER TRAN.
Appendix: Installation 1. SUMMARY 1.1 Notice This operation manual has explicit information for installation and maintenance in most conditions. Contact the local distributor or after-sales service for further information. 1) Wiring notice Only qualified professionals should carry out wiring of the appliance.
Appendix: Installation 8 2. INSTALLA TION LOCATION 2.1 Indoor unit 2.2 Outdoor unit ! ! WARNING WARNING Maintain the required space around the appliance to prevent overheat.
Lining cover Back cover Refrigerant tube Electrical cable Air exchange tube ! CAUTION Appendix: Installation 3. INSTALLA TION OF INDOOR UNIT 3.1 Take off the back cover 1) Release the clips as shown by the mark " " on the back cover.
Appendix: Installation Figure 14 3.5 Wiring (1)Before wiring, make sure the rated voltage indicated on the nameplate conforms to the local power voltage. (2)Wiring should be carried out in accordance with the instructions on the electrical schematic diagram (Figure 14).
Min. 8mm Thickness of 8mm Heat insulation materials Tapered nuts Copper tube Flarer 5.REFRIGERANT TUBE 5.1 Flaring the tube (1) Cut the tube with a tube cutter to the desired length (30.50cm is recommended) (2) Smooth the edge of the copper tube with a reamer or a file.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Hisense Group KF-5002GWE c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Hisense Group KF-5002GWE - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Hisense Group KF-5002GWE, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Hisense Group KF-5002GWE va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Hisense Group KF-5002GWE, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Hisense Group KF-5002GWE.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Hisense Group KF-5002GWE. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Hisense Group KF-5002GWE ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.