Manuel d'utilisation / d'entretien du produit DMH24DB-1 du fabricant Heat Controller
Aller à la page of 35
Wall Mounted Multi-Split System Air Conditioning/Heat Pump DMC24DB-1 DMH24DB-1 Befor e servicing the unit, r ead the “safety pr ecautions” in this manual.
2 Multi type Air Conditioner Multi type Air Conditioner Ser vice Manual T ABLE OF CONTENTS Combination table ....................................................................................................................................... 3 Safety Precautions .
Ser vice Manual 3 Operation 1 Unit 2 Unit Combination of Indoor Unit(kBtu/h) Cooling Each Capacity Unit-A Unit-B UNIT-A(Btu/h) UNIT-B(Btu/h) Total Btu/h kW UNIT-A(Btu/h) UNIT-B(Btu/h) Btu/h kW Total C.
4 Multi type Air Conditioner Saf ety Precautions Safety Precautions T o pre v ent injur y to the user or other people and proper ty damage, the f ollowing instructions must be f ollow ed. ■ Incorrect operation due to ignoring instruction will cause har m or damage.
Ser vice Manual 5 Saf ety Precautions Do not install, remove, or re- install the unit by y ourself (customer). • There is risk of fire, electric shock, explosion, or injury. Be cautious when unpacking and installing the product. • Sharp edges could cause injury.
6 Multi type Air Conditioner Saf ety Precautions Do not open the inlet grill of the product during operation. (Do not touch the elec- trostatic filter , if the unit is so equipped.) • There is risk of physical injury, electric shock, or product failure.
Ser vice Manual 7 Saf ety Precautions When the product is not to be used f or a long time , disconnect the power b y turning off the breaker . • There is risk of product damage or failure, or unintend- ed operation. T ake care to ensure that nobody could step on or fall onto the outdoor unit.
8 Multi type Air Conditioner Saf ety Precautions Do not expose the skin direct- ly to cool air f or long periods of time. (Don't sit in the draft.) • This could harm to your health. Do not use the product f or special purposes, such as preserving foods, w orks of ar t, etc.
Ser vice Manual 9 Saf ety Precautions Do not rechar ge or disassemble the batteries. Do not dispose of batteries in a fire. • They may burn or explode. If the liquid from the batteries gets onto y our skin or clothes, wash it well with c lean water .
10 Multi type Air Conditioner Dimensions Dimensions Indoor Unit Split T ype Indoor Installation plate D H W W mm(in) 895(35.2) H mm(in) 282(11.1) D mm(in) 165(6.
Ser vice Manual 11 Outdoor Unit W D L1 L2 L4 L3 H L7 L5 L6 W mm(in) 870(34.3) H mm(in) 800(31.5) D mm(in) 320(12.6) L1 mm(in) 370(14.6) L2 mm(in) 25(1.
12 Multi type Air Conditioner Product Specifications Pr oduct Specifications DMC24DB-1 23,600/24,000 11,800/12,000 208/230V -- 2.4(0.085) 1.2(0.042) at 230V 1Ø, 208/230V, 60Hz Indoor – 9.4(331.9) Outdoor 53(1871.8) Indoor – 36/32/29 at 230V Outdoor 54 2,390/2,390 1,420/1,420 -- 10.
Ser vice Manual 13 Product Specifications DMH24DB-1 23,600/24,000 11,800/12,000 208/230V 23,600/24,000 11,800/12,000 2.4(0.085) 1.2(0.042) at 230V 1Ø, 208/230V, 60Hz Indoor – 9.4(331.9) Outdoor 53 Indoor – 36/32/29 at 230V Outdoor 54 2,390/2,390 1,420/1,420 2,440/2,440 1,620/1,620 10.
14 Multi type Air Conditioner Installation Installation Type "A" screw and plastic anchor Type "B" screw Remote Control Holder Installation plate Figure Figure Name Screw driver El.
Ser vice Manual 15 Installation Indoor unit 1. Do not hav e any heat or steam near the unit. 2. Select a place where there are no obstacles in front of the unit. 3. Make sure that condensation dr ainage can be conv e- niently routed aw a y . 4. Do not install near a doorwa y .
16 Multi type Air Conditioner Installation Multi Piping T ype Piping length and elev ation 24k 30m(100ft) 15m(50ft) 3m(10ft) 7.5m(25ft) 7.5m(25ft) Capacity(Btu/h) Max total length of all pipes (A+B) M.
Ser vice Manual 17 Installation The wall you select should be strong and solid enough to prevent vibration 1. Mount the installation plate on the wall with type "A" screws. If mounting the unit on a concrete wall, use anchor bolts. • Mount the installation plate horizontally by aligning the centerline using a level.
18 Multi type Air Conditioner Flaring Work and Connection of Piping Flaring w ork Main cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the following procedure. Cut the pipes and the cable. 1. Use the piping kit accessory or the pipes purchased locally.
Ser vice Manual 19 Flaring Work and Connection of Piping Check 1. Compare the flared work with the figure by. 2. If a flared section is defective, cut it off and do flaring work again. Indoor 1. Prepare the indoor unit's piping and drain hose for installation through the wall.
20 Multi type Air Conditioner Flaring Work and Connection of Piping 4. Indoor unit installation Hook the indoor unit onto the upper portion of the installa- tion plate.(Engage the two hooks of the rear top of the indoor unit with the upper edge of the installation plate.
Ser vice Manual 21 Flaring Work and Connection of Piping 1. Route the indoor tubing and the drain hose to the required piping hole position. 2. Insert the piping, drain hose, and the connecting cable into the piping hole. 3. Insert the connecting cable into the indoor unit.
22 Multi type Air Conditioner Wrap the insulation material around the connecting por- tion. 1. Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there may be no gap.
Ser vice Manual 23 Flaring Work and Connection of Piping Remove the battery cover from the remote con- troller. • Slide the cover according to the arrow direction. Insert the two batteries. • Be sure that the (+) and (-) directions are correct. • Be sure that both batteries are new.
24 Multi type Air Conditioner Outdoor Align the center of the pipings and sufficiently tighten the flare nut by hand. Finally, tighten the flare nut with torque wrench until the wrench clicks. • When tightening the flare nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench.
Ser vice Manual 25 Flaring Work and Connection of Piping Connect the cable to the indoor unit by connecting the wires to the terminals on the control board individually according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and the terminal No.
26 Multi type Air Conditioner Connect the cable to the Outdoor unit. 1. Remove the cover control from the unit by loosening the screw. Connect the wires to the terminals on the control board individually as the following. 2. Secure the cable onto the control board with the holder (clamper).
Ser vice Manual 27 Connecting the Cable betw een Indoor Unit and Outdoor Unit (1) Remove two-caps on the conduit panel. (2) Make a hole appropriate for the passage of connection cable through on cap by tool. (for low voltage line) (3) Pass the connecting cable through the hole.
28 Multi type Air Conditioner Connect the cable to the indoor unit CA UTION: Pro vide a cir cuit breaker between power sour ce and the unit as shown below . Air Conditioner Circuit Breaker Use a circuit breaker or time delay fuse . Main power source Model 24k 1 Ø , 230/208V P er max.
Ser vice Manual 29 Checking the Dr ainage, F or ming the Pipings and Long Pipe Setting Chec king the drainage T o check the draina ge . 1. Pour a glass of water on the evaporator. 2. Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit.
30 Multi type Air Conditioner Checking the Dr ainage, F or ming the Pipings and Long Pipe Setting Forming the piping Form the piping by wrapping the con- necting portion of the indoor unit with insulation material and secure it with two kinds of vin yl tape .
Ser vice Manual 31 Air Purging and Ev acuation Air and moisture remaining in the refrigerant system have undesirable effects as indicated below. 1. Pressure in the system rises. 2. Operating current rises. 3. Cooling(or heating) efficiency drops. 4. Moisture in the refrigerant circuit may freeze and block capillary tubing.
32 Multi type Air Conditioner Checking the Dr ainage, F or ming the Pipings and Long Pipe Setting 1. Connect the charge hose end described in the preceding steps to the vacuum pump to evacuate the tubing and indoor unit. Confirm the "Lo" knob of the manifold valve is open.
Ser vice Manual 33 Charging ■ Each outdoor unit is factory charged (nameplate charge) for the evaporator as well as a 7.5m(25ft) line set for each indoor line. Any time total line set is used either shorter or longer then the nominal 22.5m(75ft: for tri-zone) line set length the refrigerant charge has to be adjusted.
34 Multi type Air Conditioner 1. Check that all tubing and wiring have been properly con- nected. 2. Check that the gas and liquid side service valves are fully open. 1) Prepare remote controller Remove the battery cover by pulling it according to the arrow direction.
Ser vice Manual 35 Operation 1. MAIN UNIT FUNCTION • DISPLA Y Operation Indicator • On while in appliance operation, off while in appliance pause • Flashing while in disconnection or short in Thermistor (3 sec off / 0.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Heat Controller DMH24DB-1 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Heat Controller DMH24DB-1 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Heat Controller DMH24DB-1, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Heat Controller DMH24DB-1 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Heat Controller DMH24DB-1, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Heat Controller DMH24DB-1.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Heat Controller DMH24DB-1. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Heat Controller DMH24DB-1 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.