Service Manual CAUTION -Before servicing the unit, read the "safety precautions" in this manual. -Only for authorized service personnel. Thr ough-The-W all Air Conditioning HE A T CONT R OLLER, INC.
—2— 1. PREF A CE 1.1 SAFETY PRECAUTIONS ...............................2 1.2 INSULATION RESISTANCE TEST.................2 1.3 SPECIFICATIONS ..........................................3 1.4 FEATURE S ................................................
—3— 1.3 SPECIFICA TIONS 1.3.1 FOR BG-10 3A POWER SUPPLY COOLING CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) E.E.R (Btu/W.h) OPERATING INDOOR( ° C) TEMPERATURE OUTDOOR( ° C) REFRIGERANT (R-22) CHARGE (g) EVAPORATOR CONDENSER FAN, INDOOR FAN, OUTDOOR FAN SPEED (FAN/COOLING/HEATING) FAN MOTOR OPERATION CONTROL ROOM TEMP.
1.4 FEA TURES • Designed for cooling only. • Powerful and quiet cooling. • Top-down chassis for the simple installation and service. 1.5 CONTR OL LOCA TIONS 1.5.1 COOLING ONL Y MODEL • OPERA TION • Side air-intake, side cooled-air discharge.
— 5 — 2.1 MECHANICAL P ARTS 2.1.1 FRONT GRILLE 1. Open the inlet grille downward. 2. Remove the screw which fastens the front grille. 3. Pull the front grille from the right side. 4. Remove the front grille. (See Fig. 1) 5. Re-install the component by referring to the removal procedure.
Figure 7 — 6 — 2.2 AIR HANDLING P ARTS 2.2.1 ORIFICE, AND TURBO F AN 1. Remove the front grille. (Refer to section 2.1.1) 2. Remove the cabinet. (Refer to section 2.1.2) 3. Remove the 2 screws which fasten the evaporator at the left side and the right side.
— 7 — 2.2.3 SHROUD 1. Remove the fan. (Refer to section 2.2.2) 2. Remove the shroud. (See Fig. 9) 3. Re-install the components by referring to the removal procedures, above. 2.3 ELECTRICAL P ARTS 2.3.1 MO T OR 1. Remove the cabinet. (Refer to section 2.
— 8 — 2.3.4 PO WER CORD 1. Remove the control box. (Refer to section 2.1.3) 2. Unfold the control box. (Refer to section 2.3.3) 3. Disconnect the grounding screw from the Base pan. 4. Disconnect 2 receptacles. 5. Remove a screw which fastens the clip cord.
— 9 — 2.4 REFRIGERA TION CYCLE 2.4.1 CONDENSER 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the brace. (Refer to section 2.2.1) 3. Remove the 7 screws which fasten the condenser. 4. After discharging the refrigerant completely into a Freon TM Recovery System, unbraze the interconnecting tube at the condenser connections.
— 1 0 — — Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to discharge the refrigerant system using a Freon TM recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM .
— 1 1 — Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pinch-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve.
— 1 2 — 3. INST ALLA TION 3.1 INST ALLA TION REQUIREMENTS If you use an existing wall sleeve, you should measure its dimensions. Install the new air conditioner according to these installation instructions to achieve the best performance.
— 1 3 — 3.2 INST ALLA TION • Pick a location which will allow the conditioned air to blow into the area you want. Good installation with special attention to the proper position of the unit will lessen the chance that service will be needed. ITEMS IN INSTALLATION HARDWARE You may not need all parts in the kit.
P R OCEDURE If you are using the new sleeve (optionally A s u pplie d w it h y o u r unit),sk i p t o ste p 3 . Otherwise, install the plastic grille from the kit. Cut the plastic grille to 25-1/2" wide and 15-1/4" high. Place the plastic grille to the inside of the wall sleeve at the rear flange.
— 1 5 — PR OCEDURE B Redirect the louvers at the back of the wall sleeve to 60 ° angle as shown in the FIG 24 . The use of pliers is recommended. If the wall sleeve already has a rear grille, skip to step 4. If the wall sleeve does not have a rear grille or louvered panel, install the plastic grille from the kit.
— 1 6 — PR OCEDURE B CONTINUED Remove the backing from the support blocks and attach them to the inside of the wall sleeve as shown FIG 29 . Slide the baffle into slots of the support blocks. Install the new unit into the wall sleeve. Assemble trim as described in Step 6, Procedure A.
— 1 7 — Depth"D" of the e xisting wall slee v e (inches) Length "A" (inches) Suppor t Block Baffle A A 3 / 4 1- 3 / 4 4 18 D 18- 5 / 8 18- 5 / 8 D 19- 3 / 4 19- 3 / 4 D 22 FIG. 3 4 3.5 PR OCEDURE C Redirect the louvers at the back of the wall sleeve to 60 ° angle as shown in the FIG 3 0 .
— 1 8 — 7 1" high 3 / 4 " High Shim (2EA) 6" 6" FIG. 3 7 • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
— 19 — 4. TR OUBLESHOO TING GUIDE 4.1 OUTSIDE DIMENSIONS 20- 3 / 32 " (499mm) 24" (610mm) 14- 13 / 32 " (366mm) MODE TIMER POWER FAN SPEED Fan Energy Saver Cool Timer TEMP ' F F1 LOW F2 MED F3 HIGH CONDENSER COILS EV APORA T OR COILS FA N M OTO R : REFRIGERANT FLOW TURBO F AN CAPILLAR Y TUBE COMPRESSOR 4.
— 2 0 — 4.3 TR OUBLESHOO TING GUIDE In general, possible trouble is classified in two causes. The one is called Starting Failure which is caused from an electrical defect, and the other is Ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.
— 2 1 — Fails to Start Check circuit break er and fuse. Gas leakage at f eeler bulb of ther mostat Check control s witch. Only f an fails to start. Improper wiring. Def ect of fan motor capacitor . Irregular motor resistance ( ). Irregular motor insulation ( ).
— 2 — 2 2 — COMPLAINT CAUSE REMEDY Check voltage at outlet. Correct if none. Check voltage to rotary switch. If none, check power supply cord. Replace cord if circuit is open. Check switch continuity. Refer to wiring diagram for terminal identification.
— 2 3 — NAME PLATE RATING MINIMUM MAXIMUM 115V 103.5V 126.5V 208/230V 187V 253V COMPLAINT CAUSE REMEDY Check voltage. See the limits on the preceding. page. If not within limits, call an electrician. Check the wire connections, if loose, repair or replace the terminal.
— 2 4 — COMPLAINT CAUSE REMEDY Check the voltage. See the limits on the preced- ing page. If not within limits, call an electrician. Check overload, if externally mounted. Replace if open. (If the compressor temperature is high, remove the overload, cool, and retest.
— 2 5 — 5. SCHEMA TIC DIA GRAM 5.1 CIRCUIT DIA GRAM • MODEL : BG-10 3 A.
— 2 6 — 6. EXPLODED VIEW • MODEL : BG-10 3 A 567502 554160 550140 359012 352380 346811 349600 554031 149980 352115 35211A 130410 435300 43530 0A 147582 A 147581 135303 152302 147582 B 135312 349.
—27— 7. REPLACEMENT PARTS LIST MODEL: BG-103A 130410 3041A10064C BASE ASSEMBLY,SINGLE 1 EA 131400 3090A20017D CABINET 1 EA 135303 3530A10272A GRILLE,INLET 1 EA 135312 3531A18004D GRILLE ASSEMBLY,F.
Specifications and performance data subject to change without notice. HEA T CONTROLLER, INC. 1900 WELL WOR TH A VENUE • JA CKSON, MICHIGAN 49203 THE QU ALITY LEADER IN CONDITIONING AIR P/No.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Heat Controller BG-103A c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Heat Controller BG-103A - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Heat Controller BG-103A, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Heat Controller BG-103A va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Heat Controller BG-103A, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Heat Controller BG-103A.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Heat Controller BG-103A. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Heat Controller BG-103A ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.