1 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 Models: Cosmo-I30 Cosmo-I35 • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________.
3 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 4 B. Limited Lifetime W arranty.
5 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 B. Limited Lifetime W arranty (continued).
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 6 C. BTU Speci fi cations MODELS: Cosmo-I30, Cosmo-I35 LABORA TOR Y : Underwriters Laboratories, Inc.
7 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 2 2 Operat ing Instruc tions Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 8 C. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth.
9 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 I. Before Lighting Fireplace Before operating this fi replace for the fi rst time, have a quali fi ed technician : • V erify all shipping materials have been removed from inside and/or underneath the fi rebox.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 10 J. Lighting Instructions (IPI) The IPI system may be operated with four AA-cell batteries. When using batteries, unplug the transformer . T o prolong bat- tery life, remove them when using the transformer .
11 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 Initial Break-in Procedure • The appliance should be run three to four hours continuously on high. • T urn the appliance off and allow it to completely cool. • Remove fi xed glass assembly .
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 12 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care.
13 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 14 Burner Ignition and Operation Frequency: Annually By: Service T echnician T ools needed: Protective gloves, vacuum cleaner , whisk broom, fl ashlight, voltmeter , indexed drill bit set, and a manometer .
15 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual VERTICAL TERMINA TION CAP (SECTION 8.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 16 B. Design and Installation Considerations Heat & Glo gas inserts are designed for installations into solid fuel masonry or factory built fi replaces that have been installed in accordance with the National, Provin- cial, State and local building codes.
17 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 5 5 F ireplace Size Requirements Figure 5.1 Fireplace Opening In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 18 B. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing or fi nishing material closer than the minimums listed must be construct- ed entirely of noncombustible materials (i.
19 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 ..................
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 20 7 7 Installation Preparation Prepare the existing solid fuel masonry or factory built non-combustible fi rebox for installation.
21 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 B. V enting Components CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during instal- lation.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 22 Figure 8.2 CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT ADHESIVE • T rim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 8.2). • Place 3/8 inch bead of 300º F silicone on fl ue tile top.
23 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 F . Installing Adaptor and T ermination Cap For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 8.4) . T o install adaptor see Figure 8.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 24 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a quali fi ed technician (NFI certi fi ed or factory-trained) using Hearth & Home T echnologies speci fi ed and approved parts.
25 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 26 Figure 10.2 Fan Wiring Diagram BLOWERS BLOWER RECEPT ACLE BLK GRN BLK BLK GRN BLK WHT GRN BLK BLK GRN WHT BLK BLK BLK BLK PLUG.
27 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 PLUG 120V EXISTING OUTLET GRN (2) BLK (2) BLK (2) GRN (2) BLK (2) STEPS 3 & 4 WHT (2) BLOWER SPEED CONTROL (RHEOST A T) SE.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 28 1 1 11 Finishing A. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing or fi nishing material closer than the minimums listed must be construct- ed entirely of noncombustible materials (i.
29 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 A. Remove Glass Assembly See Section 12.F . B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the control cavity .
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 30 G. Air Shutter Setting Air shutter settings should be adjusted by a quali fi ed ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run.
31 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 1 3 13 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 32 IntelliFire Plus™ Ignition System (continued) Symptom Possible Cause Corrective Action 4.
33 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 1 4 14 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 34 B. V ent Kits Components Direct V ent Flex Liner Kits (see Figure 14.2) LINK-DV -30B or (LINK-DV -30): Masonry 3 inch fl ex liner kit. Expands to 30 feet. Includes: two liners, termination cap, fl ashing, and link adapter .
35 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 C. Service Parts COSMO-I30 Beginning Manufacturing Date: June 2010 Ending Manufacturing Date: ______ Part number list on following page.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 36 C. Service Parts List COSMO-I30 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
37 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 C. Service Parts Beginning Manufacturing Date: June 2010 Ending Manufacturing Date: ______ COSMO-I35 Part number list on following page.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 38 C. Service Parts List COSMO-I35 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
39 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 Service Parts COSMO-I30, COSMO-I35 Beginning Manufacturing Date: June 2010 Ending Manufacturing Date: ______ 3 4 5 6 7 8 9 10 11 12 13 14 1 2 #12 IPI V alve Assembl y IMPORT ANT : THIS IS DA TED INFORMA TION.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 40 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 7571 215 th Street West, Lakeville, MN 55044 www .heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Heat & Glo LifeStyle COSMO-I30 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Heat & Glo LifeStyle COSMO-I30 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Heat & Glo LifeStyle COSMO-I30, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Heat & Glo LifeStyle COSMO-I30 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Heat & Glo LifeStyle COSMO-I30, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Heat & Glo LifeStyle COSMO-I30.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Heat & Glo LifeStyle COSMO-I30. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Heat & Glo LifeStyle COSMO-I30 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.