Manuel d'utilisation / d'entretien du produit ST-TRC du fabricant Hearth and Home Technologies
Aller à la page of 40
1 - Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. - What to do if you smell gas • Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any phone in your building.
2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide . NO OTHER vent systems or components MA Y BE USED . This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance.
3 TABLE OF CONTENTS Safety and Warning Information ............................................... 2 Service Parts Lists .................................................................... 4 Section 1: Approvals and Codes ............................
4 * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. 2 3 Standing Pilot 3 5 6 4 7 1 8 Log Assembly (NG , LP) Exploded Parts Diagram (GN, PL) Vue éc.
5 (NG , LP) Exploded Parts Diagram / Vue éclatée des pièces IMPOR TAN T : THIS IS DA TED INFORMA TION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts.
6 * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. 12 Log Assembly 1 STANDING PILOT 2 4 5 6 3 2 (NG , LP) Exploded Parts Diagram (GN, PL) Vue écl.
7 (NG , LP) Exploded Parts Diagram / Vue éclatée des pièces IMPOR TAN T : THIS IS DA TED INFORMA TION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts.
8 * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. 9 Log Assembly STANDING PILOT 1 2 5 6 4 3 7 8 15 (NG , LP) Exploded Parts Diagram (GN, PL) Vue .
9 (NG , LP) Exploded Par ts Diagram / Vue éclatée des pièces IMPOR TAN T : THIS IS DA TED INFORMA TION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts.
10 * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. STANDING PILOT 1 3 7 8 4 6 5 2 9 Log Assembly (NG , LP) Exploded Parts Diagram (GN, PL) Vue é.
11 (NG , LP) Exploded Par ts Diagram / Vue éclatée des pièces IMPOR TAN T : THIS IS DA TED INFORMA TION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts.
12 Appliance Certification The Heat-N-Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. Certification MODELS: PIER-TRC, S T-TRC, L-CORNER-TRC, R-CORNER-TRC LABOR ATORY: Underwriters Laboratories TYPE: Direct Vent Gas Fireplace STANDARD: ANSI Z21.
13 Getting Started Introducing the Heat-N-Glo Gas Fireplaces Heat-N-Glo direct vent gas fireplaces are designed to oper- ate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
14 Figure 1. Diagram of the PIER-TRC ELECTRICAL ACCESS GAS LINE ACCESS REAR COLLARS GAS CONTROLS & LABELS BOTTOM GRILLE SIDE GLASS DOOR END GLASS DOOR TOP STANDOFFS TOP GRILLE TOP VENT COLLARS FRO.
15 Figure 2. Diagram of the ST-TRC LEFT SIDE FRONT RIGHT SIDE TOP VENT COLLARS REAR VENT COLLARS ELECTRICAL ACCESS GAS LINE ACCESS GAS CONTROLS & LABELS BOTTOM GRILLE TOP GRILLE TOP S TANDOFFS GLA.
16 Figure 3. Diagram of the L & R CORNER-TRC LEFT SIDE FRONT RIGHT SIDE REAR VENT COLLARS ELECTRICAL ACCESS GAS LINE ACCESS GAS CONTROLS & LABELS BOTTOM GRILLE SIDE GLASS DOOR TOP GRILLE END G.
17 Installing the Fireplace Step 1. Locating the Fireplace The diagram below shows space and clearance require- ments for locating a fireplace within a room. Minimum Clearances from the Fireplace to Combustible Materials Inches mm Glass Sides or Ends .
18 Framing should be constructed of 2 X 4 lumber or heavie r. Model A B C D E VENTED VENTED TOP REAR PIER-TRC 43 1/4 40 1/4 41 1/2 23 1/4 45 29 7/8 ST-TRC 47 46 41 1/2 23 1/4 45 29 7/8 CORNER-TRC’S 43 1/4 40 1/4 41 1/2 24 3/4 45 29 7/8 Figure 5.
19 NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93mm) AT EACH JOIN T. Figure 6. D-Series Direct Vent Component Specifications (5-inch inner pipe / 8 5/8-inch outer pipe) D V - 3 6 D 5 3/4” (146mm) 8 3/4” .
20 Figure 7. Vent System Components and Termination Kits Step 3. Installing the Vent System A. Vent System Approvals These models are approved to use D-series direct vent pipe components and terminations (see Figures 6 and 7). Ap- proved vent system components are labeled for identifica- tion.
21 Figure 8. Straight Up Vertical Venting STRAIGHT UP VERTICAL VENTING V (FT .) 40' MAX. (12.4 M) STRAIGHT OUT HORIZON TAL VENTING H Max. Run 24" (610 mm) Figure 9.
22 VENTING WITH ONE (1) 90° ELBOW V (F T .) H (F T .) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.86m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.
23 VENTING WITH TWO (2) 90° ELBOWS V (F T .) H + H 1 (F T .) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.86m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5' MIN. (1.5m) 15' MAX.
24 VENTING WITH TWO (2) 90° ELBOWS V H H + H 1 1' MIN. (305 mm) 2' MAX. (610 mm) 3' MAX. (914 mm) 2' MIN. (610 mm) 4' MAX. (1.22 m) 6' MAX. (1.86 m) 3' MIN. (914 mm) 6' MAX. (1.86 m) 9' MAX. (2.7 m) 4' MIN.
25 Figure 15. Venting with three 90° elbows VENTING WITH THREE (3) 90° ELBOWS 1' MIN. (305 mm) 2' MAX. (610 mm) 3' MAX. (914 mm) 2' MIN. (610 mm) 4' MAX. (1.22 m) 6' MAX. (1.86 m) 3' MIN. (914 mm) 6' MAX. (1.86 m) 9' MAX.
26 VENTING WITH THREE (3) 90° ELBOWS V (F T .) H (F T .) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.86m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 17' MAX. (5.1m) NOTE: H + H 1 = 17' MAX.
27 ! W ARNING: A 3/8 INCH (9.5 MM) BEAD OF STOVE CEMENT MUST BE PLACED AROUND THE 5 INCH (127 MM) FIREPLACE ST ARTING COL- LAR BEFORE A TT ACHING THE FIRST VENT COM- PONENT . F AILURE T O SEAL THIS JOINT MA Y CAUSE THE FIREPLACE T O OPERA TE IMPROPERL Y .
28 For V ertical Runs - The vent system must be supported every eight (8) feet (2.4m) above the fireplace flue outlet by wall brackets. T o install support bracket s for vertical runs: • Attach wall brackets to the vent pipe and secure the wall bracket to the framing members with nails or screws.
29 For Vertical Runs - One ceiling firestop is REQUIRED at the hole in each ceiling through which the vent passes. To install firestops for vertical runs that pass through ceilings: • Position a plumb bob directly over the center of the verti- cal vent component.
30 ! C. Vent Termination For Horizontal Terminations - To attach and secure the termination to the last section of horizontal vent: • Rotate and interlock the ends as described at the begin- ning of the Installing Vent Components section. • The termination kit should pass through the wall firestops from the exterior of the building.
31 ______________________________________________________________________ ______________________________________________________________________ _______________________________________________________.
32 For Vertical Terminations - To locate the vent and install the vent sections: • Locate and mark the vent centerpoint on the underside of the roof, and drive a nail through the centerpoint. • Make the outline of the roof hole around the centerpoint nail.
33 Step 4. Positioning, Leveling, and Securing the Fireplace • Place the fireplace into position. • Level the fireplace from side to side and from front to back. • Shim the fireplace with non-combustible material, such as sheet metal, as necessar y.
34 Figure 31. Gas Supply Line • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing. • At the gas line access hole the gap between the supply piping and gas access hole can be plugged with non- combustible insulation to prevent cold air infiltration.
35 Step 8. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE- VENT ACCIDENT AL FIREPLACE OPERA TION. For Standing Pilot Ignition Wiring Appliance Requirements • This appliance DOES NOT require 110-120 VAC to operate.
36 For Intermittent Pilot Ignition (IPI) Wiring Appliance Requirements This appliance requires that 110-120 VAC be wired to the junction box. Maintain correct polarity when wiring the junc- tion box. Operation using Battery Power This fireplace has an optional battery operation.
37 Step 9. Finishing Figure 35 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace. See Figures 4 and 5 for other fireplace clearances.
38 Installing the Trim Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace, but MUST NEVER overlap onto the front face. The joints between the finished wall and the fireplace top and sides can only be sealed with a 300° F .
39 ! ! Step 12. Lighting the Fireplace Y ou’ve reviewed all safety warnings, you’ve checked the fireplace for gas leaks, you know the vent system is unobstructed, and you’ve checked for faulty components. Now you’re ready to light the fireplace.
40 Maintaining and Servicing Your Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and main- tenance will depend on use and the type of installation, you should have a qualified service technician perform an appli- ance check-up at the beginning of each heating season.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Hearth and Home Technologies ST-TRC c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Hearth and Home Technologies ST-TRC - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Hearth and Home Technologies ST-TRC, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Hearth and Home Technologies ST-TRC va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Hearth and Home Technologies ST-TRC, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Hearth and Home Technologies ST-TRC.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Hearth and Home Technologies ST-TRC. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Hearth and Home Technologies ST-TRC ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.