Manuel d'utilisation / d'entretien du produit MX06 100 du fabricant American Power Conversion
Aller à la page of 37
MX06 50 MX06 100 -48 VDC POWER SYSTEMS User’s Manual (Document # 990-9 131B).
MX06 Power Plant User’s Manual Page ii Table of Contents 1 Safety First! 1 1.1. W ARNING S YMBOLS .........................................................................................................1 1.2. G ENERAL P RECAUTIONS : ...............
MX06 Power Plant User’s Manual Page iii User Ou tputs................................................................................................................... ......18 User I nputs ..........................................................
MX06 Power Plant User’s Manual Page iv Revision History Revision Date By Preliminary 15 FEB, 2000 SCG PML-0216A 07 APR, 2000 SCG PML-0216B 05 MAY, 2000 SCG PML-0216C 26 JUN, 2000 DRD PML-0216D 27 OC.
MX06 Power Plant User’s Manual Page 1 1 Safety First! It is very important to follow all safety procedures when unpacki ng, installing and operating any sort of power equipment.
MX06 Power Plant User’s Manual Page 2 2 Introduction 2.1. General Information DC Power Plants from APC have unique features that make them easy to in stall, maintain, and upgrade. The rectifier units are modular and tr uly “hot-pluggable” into the shelf assembly without any separate AC wiring.
MX06 Power Plant User’s Manual Page 3 AC DC Control AC DC Control AC DC Control AC DC Control AC DC Control J3 USER ALARM INPU TS J2 ALARM RELAY OUTPUTS J5 MOTORIZED BREAKER CONTROLS J4 TEMPERATURE .
MX06 Power Plant User’s Manual Page 4 2.2. How to Use This Manual Each section of this manual ca n be read in any order and provi des a complete explanation of the subject described by the title. However, the sequence of the sections is designed to provide a typical step-by-step process fo r successful use of the equipment.
MX06 Power Plant User’s Manual Page 5 3 Installation 3.1. Unpacking Equipment Remove equipment from packing material and inspect for shipping damage or missing items. It is important to report damage or material shortages to the shipping carrier while a representative is on site.
MX06 Power Plant User’s Manual Page 6 Ventilation The rectifier modules for this system have fans t hat provide front-to-rear airflow for internal cooling. The power system housing should be moun ted such that there is free airflow to the front and back of the unit.
MX06 Power Plant User’s Manual Page 7 3.4. Battery Connections WARNING : Hazardous energy levels are present on bare conductors in the -48VDC distribution connec tion area of the plant. Accidental shorting of distribution conductors can cause ar cing and high currents that can cause serious burns or other physical harm.
MX06 Power Plant User’s Manual Page 8 Figure 3.4-1 Battery Cable Connection Locatio ns Battery LVD Connection The MX06 provides control for a motorized circ uit breaker on the –48 V battery string. This motorized circuit breaker is mounted on the ba ck of the MX06.
MX06 Power Plant User’s Manual Page 9 CM NO NC Yellow Yellow Brow n Orange 1 1 Batt Alm 2 2 Brown 3 3 Black 4 4 Orange 5 5 +BAT 6 6 Blue Black Orange Red Blue MX06 Breaker Side Motor Side J5 Battery.
MX06 Power Plant User’s Manual Page 10 Battery Temperature Probe Installation The 15 Ft (4.5m) temperature probe is used to m onitor the battery string temperature. To get the most representative temperat ure measurement, the probe should be placed in contact with a battery cell that is centrally loca ted.
MX06 Power Plant User’s Manual Page 11 3.6. Load Protection Installation Circuit Breaker Installation Standard circuit breaker output boar ds are available with two 30 Amp break ers or one 60 Amp breaker. Output boards are instal led at the factory and are not fiel d replaceable un its.
MX06 Power Plant User’s Manual Page 12 3.7. Load Connections Cable Size Considerations The DC load cable(s) should be sized to limit the voltage drop fr om the DC power plant to the loads per system design requirements. The cable( s) must also carry the full load current during battery operation.
MX06 Power Plant User’s Manual Page 13 GMT Fuse protected Load Connections Connections for ¼ to 15 Amp DC loads require a ring terminal with a 0.170 in (4.3 mm) clearance hole and are located at the rear of the unit. Load Connections should be made as shown in Figure 3.
MX06 Power Plant User’s Manual Page 14 RELAY OUTPUT J2 CONNECTOR DESIGNATIONS OUTPUT RELAY NOTES NC 1 MAJOR C 2 NO 3 NC 4 MINOR C 5 NO 6 NC 7 VERY LOW V C 8 NO 9 Figure 3.8-1 Output Relay Connections External Alarm Input Connections Four user-defined alarm inputs are provided on connector J3.
MX06 Power Plant User’s Manual Page 15 3.9. Rectifier Module Installation WARNING : Rectifier DC output ci rcuits will be damaged if battery is installed incorrectly.
MX06 Power Plant User’s Manual Page 16 5) Use a Digital voltmeter to measure t he system voltage using the “RTN” (+) and ”-NEG V” (-) test points on the fr ont panel. The volt age is set at the factory for –54.0 V dc. Use the “V ADJ” potent iometer to set th e voltage to the desired level.
MX06 Power Plant User’s Manual Page 17 4 T echnical Description The various MX06 models are modular stand-alon e –48 V dc power plants. Each can be configured to support most typi cal applications within their specified current capacity without special application eng ineering or assistance.
MX06 Power Plant User’s Manual Page 18 4.2. System Management A single plug-in circuit card provides the contro l, display and user interface functions for the MX06. Features include the following: Control Functions a) The Control Module is “hot-pluggable”.
MX06 Power Plant User’s Manual Page 19 User Inputs t) Temperature Probe: Provides input for battery voltage tem perature compensation. This feature operates only when the probe is attached. u) User Alar m Inputs: Four inputs are provided for user alarm inputs.
MX06 Power Plant User’s Manual Page 20 Battery Low Voltage Disconnect In order to prevent damage to the battery due to deep discharge, the DC power system has hardware support for a battery Low Voltage Disconnect (LVD). A battery LVD has the lo ads attached to the rectifiers and the battery is di sconnected from the system.
MX06 Power Plant User’s Manual Page 21 5 Operation 5.1. Description The MX06 is designed for years of operation with no user input. T he power system is pre-set at the factory with all parameters needed for normal operation. The front panel LEDs and the alarm output relays, indicate the general health of the unit.
MX06 Power Plant User’s Manual Page 22 MX06 External Alarm Input Configuration The MX06-50 and the MX06-100 alarm input circuitry is the same for both controllers.
MX06 Power Plant User’s Manual Page 23 MX06-50 Rectifier Configuration The system Controller Board must know if a rectifier is present for eac h of the five slots. This is done by the properly setting the dipswitch S2 (“R ECT PRESENT”) on the Co ntroller Board.
MX06 Power Plant User’s Manual Page 24 MX06-50 Temperature Probe Selection Temperature compensation can be configured for either a Fahrenheit or Celsius probe by the use of configuration jumpers on pin header J4 shown in Figure 5. 3-1. The MX06-50 is factory set for Fahrenheit operation, with jumpers on all position of J4.
MX06 Power Plant User’s Manual Page 25 MX06-100 Programmable Alarms The GMT alarm, and the battery circuit breaker alarm can each be programmed to either MAJOR or MINOR alarm priority. A three-pin jumper header is used for each alarm in the manner shown in Figure 13.
MX06 Power Plant User’s Manual Page 26 6 Specifications The overall system specifications can vary, depending upon the number of rectifier modules. Note that some specification items are provided on a “ per rectif ier” basis and must be combined or totaled for a given system configuration.
MX06 Power Plant User’s Manual Page 27 MX06 100 Power System Nominal Input Voltage 90, 115, 208, 230 VAC Input Voltage Range 85 – 264 VAC AC Frequency Range 47 – 63 Hz Apparent Power Factor 99% Typical, 98% Minimum Input Current 55 Amps @ 115 Volts AC 37 Amps @ 230 Volts AC 6.
MX06 Power Plant User’s Manual Page 28 MX06 50 Power System Output Voltage (factory programmed) 54.0 VDC Operating Voltage Range 47 – 57 VDC Rated Output Current 52.5 A Efficiency 85% Typical Over Voltage Protection 59.5 Volts DC Output Current 45 Amps Minimu m Continuous at 115 VAC Input 52.
MX06 Power Plant User’s Manual Page 29 6.3. Controls and Indicators TWF0500H5401 Rectifier FAIL LED DC output voltage below (-) 39.5 Volts DC or above (-) 59.5 Volts DC. MX06 Controller Voltage Good LED (Green) On when vo ltage is between 50 and 57 Volts.
MX06 Power Plant User’s Manual Page 30 Magnum VS 50 Power System Dimensions 5-1/4 in (13.3 cm) high x 17-1/4 in (43.8 cm) wide x 12.5 in (32 cm) deep Weight 12 lbs. (5.5 Kg) Color Grey Front, Yellow zinc sides and back Mounting 19” Rack Mounting (23” Optional) Magnum VS 100 Power System Dimensions 10-1/2 in (26.
MX06 Power Plant User’s Manual Page 31 6.6. Compliance NEBS NEBS Level 3 Safety UL 1950 / CE EMC FCC Part 15, Subpart J, Class A EN50081-1, EN50082.
MX06 Power Plant User’s Manual Page 32 7 APC W orldwide Customer Support Customer Support for this or any other APC product is available at no charge.
MX06 Power Plant User’s Manual Page 33 8 Limited Pr oduct W arranty The limited warranty pro vided by American Power Co nversion Corporation ("APC") in this Statement of Limited Factory Warranty applies only to Produc ts Buyer purchases for your commerc ial or industrial use in the ordinary course of Buyer's business.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté American Power Conversion MX06 100 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du American Power Conversion MX06 100 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation American Power Conversion MX06 100, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le American Power Conversion MX06 100 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le American Power Conversion MX06 100, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du American Power Conversion MX06 100.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le American Power Conversion MX06 100. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei American Power Conversion MX06 100 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.