R 7 SA FE T Y N OTICE PLEASE RE AD T H IS EN TIR E M AN U AL BEFORE Y OU I N S T ALL AN D U SE Y OU R N EW R OOM H EA TER. FAILU RE T O FOLLOW I N ST RU C TI ON S MA Y R ESU L T IN PROPER TY DAM AGE, BODI L Y IN JU R Y , OR EV EN D EA TH . FOR U S E I N T H E U .
Ex ception T L2 00 W ood Stov e 2 Specifications 3 Op er ation 5 Buildin g a Fire 7 Mainte nance 9 Instal l atio n 11 Doo r Installation Tips 13 Linkage Installation 14 Chim ney S y stem 17 Par ts List 21 Par ts Diagram 22 W ar ranty 23 T a ble of Co nte nt s Int ro d u ct io n Th e H arm an TL2 00 m ee ts t he U .
Ex ception T L2 00 W ood Stov e 3 Sp ec ifi c a tio ns W ei g h t 440 l b s Fl u e Siz e 6 in c h Log Leng th R ec om m e n d e d 18" w ith 20 " Max He atin g Ca p ac ity 150 0 to 280 0 s q . ft. Av er ag e Em is sions 4.4 Gram s Per H r . Em is sions on Low 2.
Ex ception T L2 00 W ood Stov e 4 A ndi r ons Gr a t e s T op Lo ad O pen i n g F ront Loa d Door Co mb inat ion T o p L o a d D o o r a n d Da mp er A rm A s h D o o r Ash Door Lat ch F ront L oad D .
Ex ception T L2 00 W ood Stov e 5 A l l d o ors m u s t be cl os ed w h i l e the st ov e i s i n no rm a l operati on, and the gaskets rou t in e l y e x a m i n ed for wear and re p lace d wh e n n ec es sa ry . T he fuel d oo r m a y be left op e n a n d t h e o p en in g cov er e d with a s c r ee n whe n op e ra t- in g a s a f i re pl ac e.
Ex ception T L2 00 W ood Stov e 6 The Com bustio n Pr ocess C om b u s t ion i n y o u r H arm an Ex c e p ti on is con tr o l le d very p rec isely . D urin g a wo o d fire, p ri m a ry co m b ustion.
Ex ception T L2 00 W ood Stov e 7 A ir Control T h e air con t r ol l ev e r i s l o c ated d irectl y bel ow t he ash l ip o f th e stove. U s i ng this le v er y ou wil l be ab l e to v ar y t he am oun t of a ir d e l ive re d t o t h e fi r e , crea t ing a ra ng e of h e at outp uts.
Ex ception T L2 00 W ood Stov e 8 Op er ating a s a Fireplace T he TL2 0 0 i s t e s ted a n d ap p ro ved to be bu rn ed w i th th e f ro n t lo ad doo r o pen a n d th e d a m p e r ope n . I n t his m od e of op e rati on yo u get a true fi re s oun d as wel l as app ea r- ance.
Ex ception T L2 00 W ood Stov e 9 Ma inte n an ce The Fire Cham ber T he insi d e of th e fi re c ham b e r s h o u ld be exam - ined for dam age t o the ref rac tory lin i n g m a teri al, g ra tes , casti n g o r Aft erbu rner gl a s s .
Ex ception T L2 00 W ood Stov e 10 The Chim ney S y stem Creo sote W hen woo d i s b u rn e d s l o w ly , i t p ro d uces tar and oth er org ani c v ap o rs , a s w ell as s o o t, w hich co m b i n e w i th ex p e l l e d m o is t u re to f orm c r e os o te .
Ex ception T L2 00 W ood Stov e 11 DO N OT I NST ALL I N A SLEE PI N G RO OM B low er Va riable Sp e ed k nob 3" Outsid e A ir I n s t a ll ati on A s sem b ly Blow er (op tional) Bolt the m o u ntin g p late to th e b o tto m re ar o f the st o v e w it h f o u r 1/ 4-20 bo l t s.
Ex ception T L2 00 W ood Stov e 12 I n s t a ll ati on Floo r Pr ot ection In all i n s ta l latio n s , the a rea un d e r and a ro u nd the st ov e m u s t be protec te d f rom fall i n g as h an d l i ve c oals. T h e ar ea u n der a h o r i zo n t al r un of c h i m ney con nec t or m ust al s o b e p rot ec t e d .
Ex ception T L2 00 W ood Stov e 13 Do or Ass em bly /I ns t a llation T ips Doo r Glass • Be s ure that the door g l a ss i s in s tall e d i n th e d oo r with the l a b el , loca ted on t he gl as s, o n th e e x t ern a l sid e of th e d o o r . • Rop e the g lass c are ful l y to in s u re proper s ealin g.
Ex ception T L2 00 W ood Stov e 14 Ex ce ption Link ag e I ns t a llati o n Fig u r e 1 Step 1: Rem ov e left s ide shield T he s ide s h ie l d h a s tabs o n it th a t latc h i n to hol e s on t h e si d e o f th e s tov e. T his m a k e s rem ov ing the si d e shield e a s y .
Ex ception T L2 00 W ood Stov e 15 Fig u re 5 Fig u re 6 Sel f -Lock i n g N u t Sh o u ld e r Pin Be f or e t igh t eni ng the n ut be s u re the b o l t is tigh t in th e l i d . Ex ce ption Link ag e I ns t a llati o n , c on t'd Sel f -Lock i n g N u t Step 2: In s t a ll the t op lift/d r iv e arm Step 4: Re- a tt ach left side shield.
Ex ception T L2 00 W ood Stov e 16 Ex ce p t io n Lin ka ge I n st allation , c on t'd Fig u re 7 T op L ift A rm Lift Lu g 1/4 x 20 " Self Lo cking N u t 1/4 x 20 " Bu tton h ead A l l.
Ex ception T L2 00 W ood Stov e 17 T h e H a rm a n Exc e pt io n may b e i n s ta l le d wi th a minimu m o f (1 50 m m) 24 ga uge c hi m ne y co nnec to r pi pe . Si z e o f th e co n n ec to r s h o u l d co rr e s po nd t o th e s ize of t h e f l u e c olla r o pen ing .
Ex ception T L2 00 W ood Stov e 18 The Ch im ney T he Exceptio n m ust b e insta l led in t o a c h i m n e y app rov ed for u s e wi th solid-fu el app l i ances .
Ex ception T L2 00 W ood Stov e 19 Exi stin g M asonry Chim ney s If y o u p lan o n u s i n g a p re -exist in g m a so n ry c him - n e y , have i t thoroug h l y inspe ct ed an d c l e aned . A n y fau lts wh i ch m a k e the ch im n e y u nsaf e a n d u nu s abl e m u s t b e repai re d p ri or t o use .
Ex ception T L2 00 W ood Stov e 20 Moblie Hom e Installations Mob i l e h o m e in s ta l latio n s m u s t use app rov ed fac - tory - bu ilt c h i m ney s tes te d and lis t ed fo r thi s s p e ci fic use, to e ith er o f th e hig h tem p e r atur e s t and a rds , U LC S- 6 29 o r U L 1 03.
Ex ception T L2 00 W ood Stov e 21 Ex ce ption Pa rt s L ist 1. 1-10 -080 74 Da m per l in kag e w e l d m ent 2. 1-10 -080 75 Da m per p iv o t ar m w el d m e n t 3. 1-10 -081 27 T op l ift ar m w el d m e n t 4. 2-00 -052 04 Lef t sid e s h iel d 5.
Ex ception T L2 00 W ood Stov e 22 1 2 3 4 5 6 7 8 9 10 1 1 13 14 15 1 6 17 18 19 20 21 22 23 24 27 28 30 31 32 33 34 35 36 37 38 39 40 41 Ex ce ption ( T L 20 0) Pa rt s.
Ex ception T L2 00 W ood Stov e 23 Harm an S to ve C o m pan y wa rran ts its pro du cts to be f ree f ro m defects in ma terial o r w o rk man sh ip, in n o rm al u se an d ser vice, f or a per io d .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Harman Stove Company TL200 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Harman Stove Company TL200 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Harman Stove Company TL200, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Harman Stove Company TL200 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Harman Stove Company TL200, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Harman Stove Company TL200.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Harman Stove Company TL200. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Harman Stove Company TL200 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.