ShowerArc 26396001 Installation Instructions / W arranty.
2 ShowerArc 26396001 Minimum ceiling height – 90 1/2”.
3 For best results, Hansgrohe recommends that this unit be installed by a licensed, professional plumber . Please read over these instructions thor- oughly before beginning installation. Make sure that you have all tools and sup- plies needed to complete the installation.
4 Installation in 90º corner: Instructions begin on page 5 W all-to-wall installation Requires 26397000 installation kit (included): Instructions begin on page 13.
5 Only one set of supplies is required – do not install two sets of supplies . Installation in 90º corner The thermostatic mixing valve may be installed on either wall.
6 Installation in 90º Corner Seal the wall around the supplies with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 3 4.
7 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 5 6 7 8.
8 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Be careful not to drill into water lines! 9 10 11 12 6 mm.
9 13 14 15 16.
10 1 2 17 18 19 20 6 mm.
11 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 21 22 23 24 6 mm.
12 T urn to page 22 to continue the installation. Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage.
13 The thermostatic mixing valve may be installed on either wall. The diagram shows both possible positions for the installation. Only one set of supplies is required – do not install two sets of supplies .
14 W all-to-W all Installation Seal the wall around the supplies with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 3 4.
15 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 5 6 7 8.
16 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Be careful not to drill into water lines! 1 2 6 mm 12 9 10 11.
17 Install the 26397000 mounting set 13 14 15 16.
18 XX 90 XX = 17 18 19 20.
19 6 mm SW 3 mm M6x8 1 2 24 21 22 23.
20 Install the 26397000 mounting set M6x60 1. 2. 3. SW 3 mm M6x8 25 26 27 6 mm 28 Seal the wall around the an- chors with waterproof sealant. Failure to seal the wall can lead to possible water damage.
21 T urn to page 22 to continue the installation. SW 3 mm M6x8 29.
22 Install the Cover , Escutcheon, and Handle Install the Showerhead and Handshower 2 1.
23 Reset the High T emperature Limit Stop Loosen the handle screw with a 3 mm Allen wrench. Remove the retainer clip and stop ring from the stem. T ur n the stop unit to the handshower position. T ur n the temperature control stem until the output water is the desired high temperature -- usually 110º.
24 T ur n the stop unit to the off position. Install the stop ring so that the tooth is against the stop. Install the clip. Install the handle. T ighten the handle screw with a 3 mm Allen wrench.
25 Justify the Handle T ur n the diverter handle to the handshower position. T ur n the temperature control knob until the output water is 100ºF . T ur n the diverter handle to the off position. Loosen the handle screw with a 3 mm Allen wrench. Remove the handle.
26 User Instructions Using the Handshower T ur n the function lever to until the desired spray mode has been obtained. T ur n the temperature control knob to change the tem- perature. T ur n it clockwise to make the water cooler , counter-clockwise to make the water warmer .
27 If necessar y , pour about 3/4” of a commercial scale remover , such as Lime-A way or CLR, into a shallow dish. Soak the spray face for the amount of time shown in the label instructions. Rinse the spray face with clear water . Reinstall the handshower .
28 Replacement Parts 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 17 25.
29 1 wall flange 96768000 2 escutcheon 96767000 3 branch connection 97496000 4 branch connection 97497000 5 shower hose 28276000 6 handshower 28504001 7 handshower holder 28321000 8 body spray 9760300.
30 Problem Possible Cause Solution Unit outputs both hot and cold water , but it does not mix not a product defect -- the hot and cold supplies are reversed correct the plumbing W ater temperature doe.
31 Limited Lifetime Consumer W arranty This product has been manufactured and tested to the highest quality standards by Hansgrohe, Inc. (“Hansgrohe”). This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1, 1996, and installed in either the United States or Canada.
Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 T el. 770-360-9880 • Fax 770-360-9887 www .hansgrohe-usa.com US - Installation Instructions • Part No.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Hans Grohe ShowerArc 26396001 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Hans Grohe ShowerArc 26396001 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Hans Grohe ShowerArc 26396001, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Hans Grohe ShowerArc 26396001 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Hans Grohe ShowerArc 26396001, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Hans Grohe ShowerArc 26396001.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Hans Grohe ShowerArc 26396001. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Hans Grohe ShowerArc 26396001 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.