SpeedDome Ultra VII Day/Night Camera Dome RAS917LS RAS917LS-1 RAS917WLS RAS917WLS-1 Configuration Utility Operator’s Manual 8200-0184-04 D.
.
SpeedDome ® Ultra VII Day/Night Camera Dome Configuration Utility Operator’s Manual Version - 0710-0147-0107.
EQUIPMENT MODIFICATION CAUTION Equipment changes or modifications not expressly a pproved by Sensormatic Electronics Corporation, the party responsible for FCC compliance, could void the u ser's authority to operate the equipment and could create a hazardous condition.
T ABLE OF CONTENTS PREFACE: BEFO RE YOU BEGIN ...................................................................................................................................... V What’s In Th is Manu al? .........................................
CHAPTER 7: DISPLAYIN G DOME INFORMATION ......................................................................................... ............... 7–1 Understanding the Dome Informati on Scre en .......................................................
PREF A CE Before Y ou Begin This preface provides important information that you should be familiar with before using the SpeedDome Ultra VII Day/Night camera dome. It includes a docum ent overview, text conventions, a list of related documents, a nd how to obtain product help.
What’s In This Manual? The SpeedDome Ultra VII Day/Night Camera Dome Configuration Utility Operator's Manual is organized as follows: • Chapter 1 , Using the Dome Configuration Utility , describes how to use the SpeedDome Ultra VII Day/Night Camera Dome configuration utility.
Text Conventions This book uses text in different ways to identify different kinds of information. Bold Italics Used for terms specific to the syst em, and text that requires special emphasis, for example Preset . Italics Used for menu selections or settings, for example, On-screen Text Display.
NOTES: viii SpeedDome Ultra VII Day/ Night Operator's Ma nual.
CHAPTER 1 Using the Dome Configuration Utility The SpeedDome Ultra VII Day/Night camera dome is a 23X optical zoom camera enclosed in a compact dome housing. It provides a black-and-white m ode to enhance images obtained under low lighting conditions.
What is the Dome Configuration Utility? The Dome Configuration Utility provides a means to setting features for your camera dome via a text overlay menu.
Working with the Dome Configuration Utility Once the Dome Configuration Menu is displayed, you may select a menu item, and then modify the settings you want to change. The following table summarizes the controller comm ands for SensorNet , RS-422 , and Manchester protocols.
To enter the password using SensorNet, RS-422, or Manchester protocols: 1. Use the Pan/Tilt control to move the highlight the appropriate character. 2. Press Focus to enter the highlighted character. If you need to change a charact er that has been entered: • Zoom In moves the cursor to the right in the Password field.
Exiting the Configuration Utility Under SensorNet, RS-422, and Manc hester protocols, you may save your changes and exit the utility from any screen by pressing and holding Iris Close , then pressing Focus . From the Dome Configuration Menu , you have two choices for exiting the utility: Exit and Save Changes or Quit Without Saving .
Quick Set Command Description 0+Quick Set Toggles between displaying and hiding the quick set menu. 1+ Quick Set Displays the SpeedDome Ultra configuration menu. Refer to the dome manual for inform ation about the available settings. 2+ Quick Set Resumes Auto Focus/Auto Iris mode.
Where To Go Next Now that you understand how to start and work with the Dome Configuration Utility, you are ready to begin changing the settings for your dome.
Chapter Topics Covered Chapter 6: Configuring Language and Password Settings − Choose the language for the menus and prompts − Set a password to limit access to the Dome Configuration Utility − .
CHAPTER 2 Configuring Pan, T ilt, Zoom, and Synchronization Options This chapter describes the use of the Pan/Tilt/Zoom/Sync Opts menu. Use this screen to set the Auto Flip feature, configure the Zoom Stop settings , set the Line Lock option, and configure the Freeze Frame setting.
Overview of Pan / Tilt / Zoom/Synchronization Options Screen When Pan/Tilt/Zoom/Sync Opts is selected from the Dome Configuration Menu , the following screen appears: PROP ORTIONAL FLIP OFF/ ON 1ST ZO OM S TOP X 35/ 23 MAX TO TAL ZOO M X 46.
Adjusting the Zoom Stop Settings The SpeedDome Ultra VII Day/Night dome includes a 23X optical zoom cam era with 10X digital zoom capability. The maximum possible zoom is 230X .
Configuring the Line Lock Setting Use the Line Lock setting to prevent vertical rolling or adjust the appearance of overlay text on color monitors. If you experience problems with vertical video rolling when switching multiple cameras to a single monitor, enabling the Line Lock setting phase locks the video with the AC power line.
Configuring the Freeze Frame Setting If you need to maintain a static image when calling autom atic functions, such as presets or patterns, use the Freeze Frame setting. This prevents the disp lay of the dome movement and lens adjustm ents from being displayed on-screen while the preset or pattern is being sought.
Changing the Freeze Frame Setting 1. Select Pan/Tilt/Zoom/Sync Opts from the Dom e Configuration Menu . 2. Move the highlight bar to Freeze Frame . Change the setting. • Select On to enable Freeze Frame. This freezes the current scene when presets or patterns are selected.
What To Do Next When you select Exit from the Pan/Tilt/Zoom screen, the Dom e Configuration Menu appears. DOME CO NFI GURAT IO N M ENU PAN/ TIL T/Z OOM/S YN C O PTS CAME RA FUN CT IONS ALAR MS/ ARE AS.
NOTES: 2–8 SpeedDome Ultra VII Day/ Night Operator's Manua l.
CHAPTER 3 Configuring Camera Features This chapter describes the settings u sed to control the camera features. It describes how to change the white balance settings, IR mode , wide dynamic range settings, automatic gain control , and open shutter settings to improve camera perform ance.
Adjusting White Balance Settings White balance is normally compensated for by the automa tic white balance gain control. In som e lighting conditions, you may need to manually adjust the red and blue settings for optimal viewing. When Automatic White Balance is enabled, the red and blue setting values are based on feedback from the camera.
Changing Automatic White Balance Settings 1. Select Camera Functions from the Dome Configuration Menu . The highlight appears on the Auto White Bal setting. 2. Change the setting. • Select Off to manually adjust the red or blue settings. Continue with step 3.
For more information, see the following topics: • Changing the IR Mode Setting • Manually Activating or Deactivating the IR Mode Changing the IR Mode Setting 1. Select Camera Functions from the Dome Configuration Menu . 2. Move the highlight to the IR Mode field.
Understanding Wide Dynamic Range Wide Dynamic Range (WDR) is a feature that allows clear viewing of both bright and low light areas in a scene. Use this feature if you need to view both indoor and outdoor lighting conditions simultaneously. For example, a dome is installed in the loading doc k area of a building.
Figure 3–3: Example scene with loading do ck door open and iris open adjustment. With WDR enabled, you can see the scenes both inside and outside the loading dock area. In Figure 3–4, you can see the boxes stacked inside the load ing dock area and the car approaching the door.
Working with AGC and Open Shutter Settings The SpeedDome Ultra VII Day/Night dome provid es settings for compensating for low-light scenes in color: Automatic Gain Control and Open Shutter . Automatic Gain Control (AGC) am plifies the video signal in scenes with minimal light.
In this example, the dome receives inform ation about the color of the traffic light. While the light is red, the image is relatively static. With the s hutter limit set to 1/4 second (250 milliseconds), updated red light information is transmitted at 1/4-second inte rvals.
Configuring AGC and Open Shutter Settings Tip : The current IR mode setting affects whic h AGC Gain and Open Shutter settings are available. The Relationship between IR Mode and AGC and Open Shutter Settings chart on page 3–8 describes which settings are available.
What To Do Next When you select Exit from the Camera Functions screen, the Dome Configuration Menu appears. DOME CO NFI GURAT IO N M ENU PAN/ TIL T/Z OOM/S YN C O PTS CAME RA FUN CT IONS ALAR MS/ ARE .
CHAPTER 4 Configuring Alarms, Areas, Home, Privacy Settings, Presets and Scan Limits This chapter describes settings associated with Alarms , Areas , the Home Position , Privacy Zones , Presets and Scan Limits . It explains how to set a default action to run when a dome alarm occurs, as well as how to define the normal alarm input states.
Overview of Alarms, Areas, Home, North Position, Preset, Privacy and Scan Limit Settings When Alarms/Areas/Home/Presets/PZ is selected from the Dome Configuration Menu , the following screen appears: .
Configuring Alarm Actions IMPORTANT When operating on Manchester networks , the dome can be programm ed to respond to any of the four available alarm inputs.
Setting Alarm Actions IMPORTANT Some controllers allow the alarm actions for dom es to be specified at the controller. See the appendixes for information about which controllers support this function. Do not use both the dome configuration utility and the controller to assign the alarm actions for the same input.
Configuring Normal Input States for Alarms IMPORTANT Some controllers allow the normal input states for dom es to be specified at the controller. These controllers include VM96, AD matrices with AD2083-02A code units or AD168 matrix with the AD168CCM or AD2083-02A code unit.
Setting Alarm Input States 1. Select Alarms/Areas/Home/Presets/PZ from the Dome Configuration Menu . 2. Select Set Alarm States . 3. Select the appropriate input line, and then change the setting. • Select Open if the alarm normal input state is open.
Setting the Home Position 1. Select Alarms/Areas/Home/Presets/PZ from the Dome Configuration Menu . 2. Select Set Home Position . The highlight bar appears on the Home Position setting. 3. Select a setting. • Select Preset to use a preset as the hom e position.
Setting the North Position Direction Indicators permit you to understand the approximate pointing position of the dom e to an established reference point. This reference point is called “North” and may correspond to magnetic north (if it is known) or some other landmark or fixt ure.
Programming Area Boundaries If the dome is installed in a location where you can see numerous departments or other identifiable objects, you might want to consider programming area boundaries. Areas are programmed start- and end-points of a camera's field of view.
Note: When areas are programmed, each area is assigned a default nam e. Instructions for assigning new names appear in Chapter 5 . To program areas, select Area Boundaries from the Alarm s/Areas/Home/Presets/PZ screen.
Note: You will receive an error message under the following conditions: • If y ou attempt to program an area boundary that passes the starting point of the first area • If y ou move the cam era left after establishing the first boundary Return to step 2 and start again.
From this screen, you can program up to eight Privacy Zones, delete all or specific Privacy Zones, or temporarily hide all Privacy Zones. For more information see: Topic Page Number How Privacy Zones .
The circled arrows represent the target area on th e screen for creating the Privacy Zone. Normally, this target area remains in the center of the screen.
Removing or Hiding Privacy Zones If you make an error during programmi ng or no longer require Privacy Zones, individual zones or all Privacy Zones may be deleted. To temporarily remove the Privacy Zones, you may disable their appearance by changing the Hide All Zones setting to Yes .
Deleting Specific Privacy Zones To delete individual Privacy Zones, use the following procedure. To delete al l Privacy Zones, see Deleting All Privacy Zones on page 4–15. 1. Select Alarms/Areas/Home/Presets/PZ from the Dome Configuration Menu . 2. Select Privacy Zones .
Programming Presets If you need to view specific places routinely, y ou should program presets. A preset is a programmed video scene with automatic pan, tilt, zoom, focus and iris settings. Once programmed, entering the number and pressing a button on your controller automa tically calls up the preset.
PR ESETS PR ESET X Posit io n came ra wi th PA N TILT, Z OOM an d IRIS FOCUS FAR to sa ve and exit EXIT 4. Adjust the camera until you see the scene you want to use as the preset. Adjust the zoom and iris settings as necessary. When satisfied with the scene, save the preset.
Figure 4–6: Left and Right Scan Limits Left Scan Limit Parking Lot Building Dome Right Scan Limit Scan Types Three types of scans may be activated: smooth scan, stepped scan, and random scan. A smooth scan slowly pans between the left and right scan limits, starting at the left scan limit.
A random scan pans randomly between the left and right scan limits. For exam ple, the scan may start at point in the scan, then pan right 40° and pause, pa n right 10° and pause, pan left 20° and pause, and pan right until it reaches the right scan limit.
Note: Press Focus during steps 3 or 4 to cancel scan limit programm ing. 3. Adjust the pan position of the dome to set the left scan limit. Press Zoom to select. 4. Pan the dome to the right to set the right scan limit . Press Zoom to select. 5. When the Alarms/Areas/Home/Presets/PZ screen appears, select Exit .
CHAPTER 5 Configuring T ext Displayed On-Screen This chapter describes how to modify settings rela ted to text displayed by the dome. It includes settings for displaying dome status information , names , diagnostics , and pointing direction . It also provides instructions for programming names and configuring text display options .
Displaying or Hiding Status Information You can choose to display the status of the zoom se tting, auto focus, and auto iris. This information will appear in the upper left corner of the monito r. The information only appears when there is a change in the status of any item and remains on the screen for 5 seconds.
Displaying or Hiding All Name Information The dome provides the ability to display the dome name, the area where the dome is pointing, the name of the preset or pattern that is running, and alarm nam es. When the display of camera or area names is enabled, the information appears on the screen continuously.
Displaying Diagnostic Tests During Reset You can choose to have dome diagnostic tests run whenever the dome resets. The diagnostic information displayed includes: • Communications Loopback Test • .
Displaying Direction Indicators Direction Indicators let you know the approximate pointing di rection of the dome in relation to an established point called “North”. Directions for setting the North Position are covered in Chapter 4 . When enabled, the Direction Indicators appear along the top edge of the display.
Figure 5–5 represents pointing the dome precisely at 225° from North (Southwest) with a tilt of 25° below the virtual horizon. Panning to the left points the dome towards the South.
Changing the Display of Selected Name Information 1. Select On-Screen Text Display from the Dome Configuration Menu . 2. Move the highlight to Name Configuration Menu and select. The Name Configuration Menu appears. 3. Move the highlight bar to the item whose display setting you want to change.
Setting or Changing Names 1. Select On-Screen Text Display from the Dome Configuration Menu . 2. Select Name Configuration Menu . The Name Configuration Menu appears. 3. Select the name setting you want to change. The choices are Camera Name , Area Name , Preset Name , Pattern Name , and Alarm Name .
7. Move the blinking highlight around the availabl e characters. When the correct character is highlighted, press Focus to select it. If you make a mistake, Zoom In moves the cursor one space right, and Zoom Out m oves the cursor one space left in the name.
Figure 5–7: Examples of text attributes If the video background is light, enable character outlines. If on-screen text obscures the video being displayed, enable translucent names. Character ou tlines and translucent names m ay be used together to best suit your video environment.
What To Do Next When you select Exit from the On-Screen Text Display screen, the Dome Configuration Menu appears. Figure 5–8: Dome Configuration Menu DOME CO NFI GURAT IO N M ENU PAN/ TIL T/Z OOM/S .
NOTES 5–12 SpeedDome Ultra VII Day/Night Operator's Manual.
CHAPTER 6 Configuring Language and Password Settings This chapter explains how to change the langua ge for dome m essages and text, and how to set and enable the dome password. In This Chapter • Overview of Language and Password Settings ...........
Selecting a Language for Dome Messages and Prompts The dome supports menus, status inform ation and pr ompts in English, Spanish, French, German, Italian, and Portuguese.
4. Do one of the following: • To continue with changing the language, select Continue . The dome autom atically resets. To verify the language change, continue with st ep 5. Otherwise, continue with step 6. • To cancel the language change, select Cancel .
Enabling or Disabling Password Protection Pas rotect e password: Select an age/Password from the Dom e Configuration Menu . 3. sword protection. h What To Do Next on sword p ion must be enabled before passwords can be used. To enable or disable the dom 1.
CHAPTER 7 Displaying Dome Information This chapter explains how to display dom e information and operating information. In This Chapter • Understanding the Dome Information Screen .............................................................. 7–1 • Viewing Dome Operating Statistics .
Viewing Dome Operating Statistics When Dome Statistics is selected from the Dome Inform ation screen, the following information is displayed: DOM E S TAT IST ICS Pan Sta t Til tSt at Zoo mSt at R 0000.
What To Do Next When you select Exit from the Dome Information screen, the Dom e Configuration Menu appears. DOME CO NFI GURAT IO N M ENU PAN/ TIL T/Z OOM/S YN C O PTS CAME RA FUN CT ION S ALAR MS/ AR.
NOTES: SpeedDome Ultra VII Day/ Night Operator's Ma nual 7 – 4.
APPENDIX A SensorNet and RS-422 Command Summary This appendix summarizes the SensorNet and RS-422 controller com mands used with the Configuration Utility. It also provid es a list of compatible controllers. In This Appendix • Command Summary.......
Command Summary The following table lists the commands to operate th e configuration utility when the dome is installed in a SensorNet or RS-422 environment. If you want to … Use … Start the configuration utility. Press and hold Iris Open, press and hold a Focus button, then press Zoom Out* Move the highlight bar on the active menu.
Supported Controllers and Matrix Switching Systems This section provides information about the SensorNet and RS-422 controllers and matrix switchers that are compatible with SpeedDome Ultra VII Day/Night. Refer to the controller information for details concerning specific functions supported.
VM32/AD32 Supported Protocols SensorNet RS-422 (1) Maximum Presets 96 – SensorNet 4 – RS-422 Maximum Patterns (2) 3 Quick Set Menu Not supported Address Range 1-32 Notes: (1) Requires RCSN422 code converter. (2) Patterns are limited by time and the number of available dome commands.
AD168 Supported Protocols SensorNet (1) RS-422 (1) or (2) Maximum Presets 16 (1)(2) , 64 (1)(3) , or 60 (4) Maximum Patterns (5) 3 Quick Set Menu Not supported Address Range SensorNet: 1-180 RS-422: 1-99 (1)(6) or 1-180 (2)(6) Notes: (1) Requires the appropriate code control module.
Performance Notes The following considerations should be made wh en using the SpeedDome Ultra VII Day/Night camera dome in a SensorNet or RS-422 environm ent.
APPENDIX B Manchester Command Summary This appendix summarizes the Manchester controlle r com mands used with the Configuration Utility. It also provides a list of additional Manchester commands that can be used with the dom e and compatible controllers.
Command Summary The following table lists the commands to operate th e configuration utility when the dome is installed in a Manchester environment. The keyboard must be in programm ing mode to perform these functions. If you want to … Use … Start the configuration utility.
Additional Manchester Commands The following tables summarize the special com ma nds available when using the dome in a Manchester network. These commands are availabl e when you enter the number listed and press the Set Preset or Call Preset button on the controller.
Supported Controllers The following Manchester controllers are comp atible with SpeedDome Ultra VII Day/Night: Controller Presets Patterns Quick Set Menu Address Range AD2150 64 3 No 1-64 MP48 64 3 No 1-64 AD168/MP168 64 3 No 1-64 AD2050/2052 64 3 No 1-64 This list of controllers is complete as of the time of publication.
APPENDIX C Pelco Coaxitron and “P” Protocols Command Summary This appendix summarizes the SpeedDom e Ultra VII features that are supported by the Pelco Coaxitron and “P” protocols. In addition, it pr ovides the controller comma nds used with the Configuration Utility.
Supported SpeedDome Ultra VII Features The following SpeedDome Ultra VII Day/Night features are supported with Coaxitron and P protocols: • 10X digital zoom (up to 230X total zoom) • 85 Total Pres.
Pelco Command Summary The following table lists the commands to operate th e configuration utility when the dome is installed in a Pelco environment. If you want to … Use … Start the configuration utility. Set Preset 95 Move the highlight bar on the active menu.
Performance Notes The following SpeedDome Ultra VII features are not supported with the Pelco protocols: • PAL video format. This will be s upported after further testing. • Long line length applications that require video amplifiers or fiber optics.
Setting Left and Right Scan Limits Scan Limits allow you to set left and right boundaries fo r use with the Auto Scan, Frame Scan, and Random Scan functions. If the scan limits are not set, the dom e pans continuously to the right when these functions are activated.
Activating Frame Scan Frame Scan pans between the left and right scan limits , pausing briefly (3 seconds) at each frame. A frame is equivalent to approximately 10° when the zoom setting is 1X. If the scan limits are not programmed, the Fram e Scan pans to the right, pausing at each frame.
APPENDIX D Panasonic Up-the-Coax (UTC) Protocol Command Summary This appendix summarizes the SpeedDom e Ultra VII features that are supported by the Panasonic UTC protocol. In addition, it provides the controller commands used with the Configuration Utility.
Supported SpeedDome Ultra VII Day/Night Features The following SpeedDome Ultra VII Day/Night features are supported with the UTC (Up-the-Coax) protocol: • 10X digital zoom (up to 230X total zoom) .
Panasonic UTC Command Summary The following table lists the commands to operate th e configuration utility when the dome is installed in a Panasonic UTC environment. If you want to … Use … Start the configuration utility. Camera Set ON Set Up/Esc + Camera Move the highlight bar on the active menu.
Performance Notes When selecting a dome, a 3- to 5-second delay is necessary for the Panasonic multiplexer to properly identify the dome type. If the dome is moved before the interrogation is complete, the controller recognizes the dome as a “single speed” dome.
5. Use the joystick to move the highlight to Presets . Press Set to select. The Select Preset to Program screen displays. SELECT PRESET TO PROGRAM PRESET NUMBER PRESET NAME 1-64 PRESET 1-64 FOCUS FAR to pro gram preset EXIT 6. Use the joystick to select the Preset y ou want to program.
NOTES: D–6 SpeedDome Ultra VII Day/ Night Operator's Manua l.
APPENDIX E AD Up-the-Coax (UTC) Command Summary This appendix summarizes the AD-UTC controller com mands used with the Configuration Utility. It also provides a list of additional AD-UTC commands th at can be used with the dom e and compatible controllers.
Command Summary The following table lists the commands to operate th e configuration utility when the dome is installed in an AD Up-the-Coax (AD-UTC) environment. Th e keyboard must be in programm ing mode to perform these functions. If you want to … Use … Start the configur atio n utility.
Additional AD-UTC Commands The following tables summarize the special com mands available when using the dome in an AD-UTC network. These commands are available when y ou enter the keyboard combination provided.
Supported Controllers The following AD-UTC controllers are comp atible with SpeedDome Ultra VII: Controller Presets Patterns Quick Set Menu ADCC0200 96 3 Yes ADCC0300 96 3 Yes This list of controllers is complete as of the time of publication. Other cont rollers m ay be supported.
Quick Set Command / Menu Item Description 0+ : Toggle Quick Set Menu Toggles between displaying and hiding the quick set menu. 1+ : Dome Config Menu Displays the SpeedDome Ultra configuration menu. Refer to the dome manual for inform ation about the available settings.
E–6 SpeedDome Ultra VII Day/ Night Operator's Manua l.
APPENDIX F V icon Command Summary This appendix summarizes the SpeedDom e Ultra VII features that are supported by the Vicon protocol. In addition, it provides the controller commands used with the Configuration Utility. It also provides information about tested Vicon equipment and supported Vicon features.
Vicon Command Summary The following table lists the Vicon controller key sequence to control the indicated SpeedDome Ultra VII functions. If you want to … Use … Set Auto Iris ON/OFF (LED indicates.
If you want to … Use … Reset Dome Run/Pgm switch to PGM Enter 97 Enter Auto Pan Left Limit See Setting Left and Right Auto Pan Scan Limits on page F–4. Run/Pgm switch to PGM Enter 98 Enter Auto Pan Right Limit See Setting Left and Right Auto Pan Scan Limits on page F–4.
Setting Names / Working with Passwords When setting names or entering password information, the screen displays the available characters in the selected languages. In these situa tions, the following commands are used: If you want to … Use … Move the highlight left or right in the character field.
Setting the Auto Pan Speed 1. Press and hold A/P key. 2. Move joystick to Pan Right until the desired speed is observed on the monitor. 3. Release the A/P key. 4. Release the joystick Activating Auto Pan Auto Pan allows the dome to continuously pan between th e left and right scan limit settings.
In Vicon systems where the domes support RS-485 daisy chaining, daisy chain the SpeedDome Ultra VII domes off the controller or one of the Vicon domes in the com munications chain.
APPENDIX R Dome Configuration Records Use the pages in this appendix to record th e configuration settings for your SpeedDome Ultra VII Day/Night Camera Dome. Make copies of these pages for each dome. Whenever you change settings for a dome, update the information recorded on these pages.
DOME NUMBER: ___________________ LOCATION: ________________________ Configuration Settings Pan / Tilt / Zoom / Sync Options Menu Item Default Setting (Choices) Current Setting Proportional Flip Off (O.
DOME NUMBER: ___________________ LOCATION: ________________________ Set North Position Describe North position: Area Boundaries Up to 16 areas can be programmed. Use this form to identify the star t and end points of each area. Th is will assist you in rest oring the boundaries if t he areas should be erased.
DOME NUMBER: ___________________ LOCATION: ________________________ Text Attribute Options Menu Item Default Setting (Choices) Current Setting Character Outline On (On / Off) Translucent Names On (On .
DOME NUMBER: ___________________ LOCATION: ________________________ Presets Up to 96 presets may be program med for each dome. Use this form to describe the scene being vi ewed for each preset. This will assist you in restoring the presets i f they should be erased.
DOME NUMBER: ___________________ LOCATION: ________________________ Preset Number Description Assigned Name Preset 49 Preset 50 Preset 51 Preset 52 Preset 53 Preset 54 Preset 55 Preset 56 Preset 57 Pr.
DOME NUMBER: ___________________ LOCATION: ________________________ Dome Information Record the information found on the Dome Information screen here. The information on this screen c annot be modified and is provided for service use.
DOME NUMBER: ___________________ LOCATION: ________________________ NOTES: R–8 SpeedDome Ultra VII Day/ Night Operator's Ma nual.
APPENDIX S Software License Agreement By using this software, you accept the terms and conditions of this license agreement. Read this license agreement carefully.
Customer may make up to 2 copies of the Software solely for back-up and archival purposes. Customer will not remove or m odify the copyright and other proprietary no tices and legends of SEC and its suppliers contained in th e Software and Documentation and will reproduce all such notices and legends on all copies of the Software made by Cu stomer.
SEC AND ITS SUPPLIERS, EMPLOYEES, AGENTS AND FRANCHISEES WILL IN NO EVENT BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL OR OTHER DIRECT OR INDIRECT DAMAGES (FOR LOSS OF BUSINESS INFORMATION OR PROFITS O.
NOTES: S–4 SpeedDome Ultra VII Day/ Night Operator's Manual.
SPEEDDOME UL TRA VII GLOSSARY Alarm Actions The assigned responses for the dome when inputs change from normal to abnorm al states. The dome may run a Pr eset , Pattern , or have no assigned action for each of the four dome inputs. The dome may also send alarm states to the host controller for processing.
Flip T o automatically rotate the dome 180° from its current pointing position. See Automatic “Flip” featur e. Freeze Frame A feature that allows the current image to be maintained on-screen when switching to a preset or pattern.
Peel Button found on some controllers that initiates the Apple Peel pattern. See Apple Peel Pattern. Preset Program med video scene, based on a specific pan, tilt, zoom, and focus settings. Up to 96 presets may be programmed for the dom e. For domes running in a Manchester network, only 64 presets may be programmed.
Zoom T o adjust the magnification of the camera lens to make an object appear closer (lar ger) or farther away (smaller). See also Zoom stop factors . Zoom stop factors Defines how the zoom function is partitioned. The first zoom stop setting m ay be 23X or 35X.
INDEX –A– Activating IR m ode manuall y, 3–4 Advanced Shutter Settings Overview, 3–7 Alarm Actions Configuring, 4–3 Area Boundaries Overview, 4–9, 4–10 Programm ing, 4–10 Auto Focus co.
Scan Types random, 4–18 smooth, 4–18 stepped, 4–18 Setting Scan Limits Pelco protocols, C–5 Settings Overview Alarms, Areas, Hom e Postion, North Position, Presets and Privacy Zones, 4–2 Cam.
.
Please visit our website for more information www.americandynamics.net © 2003 Sensormatic Electronics Corporation Product specifications subjec t to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté American Dynamics RAS917LS-1 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du American Dynamics RAS917LS-1 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation American Dynamics RAS917LS-1, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le American Dynamics RAS917LS-1 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le American Dynamics RAS917LS-1, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du American Dynamics RAS917LS-1.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le American Dynamics RAS917LS-1. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei American Dynamics RAS917LS-1 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.