Manuel d'utilisation / d'entretien du produit AU422BIBAA du fabricant Haier
Aller à la page of 16
No. * 0010571564 After reading this attached manual, please keep it pr operly . If the user is changed, please do give this manual to him For the sake of safety and in order to use the air conditioner.
Characteristics of Pr oducts Characteristics of Products 1.220~230V normal power , suitable for both commercial use and home use. 2.Free choice of wire control and remote control. 3.Several types of indoor units, free combination of specification. 4.Single outdoor unit, space-saving and cost-saving.
If still using the unit under this circumstance, the air conditioner may be damaged and may also cause electric shock or fire accidents. When needing repair , please ask the after- sales service work for help. Improper maintenance and repair may cause water leakage, electric shock and fire.
Name of Parts 3 1 2 4 Repair panel Air inlet Air outlet Air inlet Note: Do not block the air inlet and air outlet, otherwise the performance of the air conditioner may be lowered.
Installation pr ocedure Install indoor unit 1.Choose installation place The chosen installation place should meet the following requirements and get the userís consent. Place air can freely circulate. Place can perform level installation. The condensate water can be drained smoothly .
Installation instruction The following is the manual mentioned standard accessories, please check them by yourself. Amount 6 Name Use screw bolt (M10) and screw nut to tightly fix the outdoor unit on its bracket, and keep it level.
Installation instruction Please perform the fastening of the screw nut according to the specified torque 2. W elding method of pipe (1)The refrigerant pipe should use clean new pipe. When performing work, pay attention to preventing vapor , dust from entering into the pipe.
Installation instruction 4.Air discharging method According to the method of the Figure shown, discharge the air in the indoor unit and pipe out. (1)Remove the valve cap of little stop valve of the outdoor unit. (2)Loosen the thick flare screw nut connected to big stop valve for about 1~1.
The Creepage breaker must be installed. If not installing Creepage breaker may easily cause electric shock. After wiring, please power on the unit to detect electricity leakage. If the power cable is damaged, in order to avoid danger , it must be changed by the manufacturer or its repair center or the similar professional personnel.
Electric wiring Power cable (connect through outdoor unit) Remove the repair panel of the outdoor unit, loosen the wire holding clamp A, then put the active wire, null wire and grounding wire of power cable through the wire holding clamp A and connect to the relative terminal block.
Electric wiring Note: The pressing method when ther e is not terminal block Connect the wire of the same diameter to the two sides of wire ends. Do not connect the wire of the same diameter to the same side of the wire end. Do not connect the wires of different diameter together .
10 Electric wiring 1. Safety checking * ** If the joint of pipe leaks? ** How about the thermal insulation of the joint of the pipe? ** If the electric wire connection of the indoor and outdoor unit i.
Operation and performance 3 minutes delay function If start the unit immediately after its stop, the compressor will operate after 3 minutes have elapsed to protect the unit. The characteristic of HEA TING operation During operation, if the outdoor temperature is too high, the fan motor of outdoor unit will automatically change to low fan speed.
T roubleshooting T rouble code display E3 E5 Phenomenon of outdoor unit trouble The trouble of outdoor ambient temperature sensor The trouble of outdoor coil temperature sensor Over electric current p.
T roubleshooting Symptom Cause Blow out mist or water overflow The fan motor of outdoor unit automatically stop to perform defrosting. * During operation, in operation and shortly after unit stop, the.
Muffler One-way valve Pipe system chart 14 Indoor unit Outdoor unit 4-way switch valve Compressor Indoor heat exchanger Outdoor heat exchanger HEA TING operation COOLING operation Note: The wiring diagram is pasted inside the unit.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Haier AU422BIBAA c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Haier AU422BIBAA - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Haier AU422BIBAA, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Haier AU422BIBAA va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Haier AU422BIBAA, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Haier AU422BIBAA.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Haier AU422BIBAA. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Haier AU422BIBAA ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.