Manuel d'utilisation / d'entretien du produit CSP du fabricant Greenheck
Aller à la page of 20
Centrifugal Ceiling and Cabinet Exhaust Fans Models SP and CSP November 2006 Making a Sound Difference with Silent Solutions.
2 Greenheck Fan Corporation certifies that the SP models shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
3 Light Options: L - Fan/Light (Incandescent) Combination FL - Fan/Light (Fluorescent) Combination SP - A 50 FL Nominal cfm at 0.10 inches static pressure Level of Construction: A - Premium unit; lowe.
4 PREMIUM CEILING FAN A SP Spring Loaded Aluminum Backdraft Damper - Eliminates rattling or unwanted backdrafts. Outlet - Both square and round outlets are field rotatable from horizontal to vertical discharge. Power Assembly - Removes quickly for maintenance or conversion from horizontal to vertical discharge.
5 PREMIUM CEILING FAN A SP The frosted lens option is a traditional design which lets approximately 80% of light through the lens. The lens may be easily removed to replace light bulbs. The prismatic lens design provides approximately 25% more light than a traditional frosted lens.
6 DELUXE CEILING FAN B SP Aluminum Backdraft Damper - Prevents unwanted backdrafts. Round Standard Outlet (4 or 6 in.) - Versatile for quick, easy connections. Power Assembly - Removes quickly for maintenance. Electrical Access (vertical) - Eliminates drilling holes.
7 DELUXE CEILING FAN B SP National Fire Protection Association (NFPA) Standard 90A requires openings in fire rated ceiling/floor assemblies be protected by appropriately rated ceiling radiation dampers.
8 STANDARD CEILING FAN C SP Plastic Backdraft Damper - Prevents unwanted backdrafts. Round Outlet - 3 inch diameter allows quick easy connections. Power Assembly - Removes quickly for maintenance. Disconnect - Servicing is quick and safe. Polymeric Grille - Quickly snaps into place.
9 ® Things to know, when sound is critical Things to know, when sound is critical Sound Data The sound data shown in this catalog has been presented to aid the system designer in selecting a fan which will meet the desired sound criteria.
10 PREMIUM INLINE FAN A CSP The CSP-A is a Premium Inline Fan. It outperforms the competition and is preferred by specifying engineers. Profile as low as 10 1 / 2 inches. Sound levels as low as 0.8 sones. Air volume as high as 3,778 cfm. UL/cUL Listed.
11 DELUXE INLINE FAN B CSP The CSP-B is a compact Deluxe Inline Fan. It is designed to fit in small remote quarters. Profiles as low as 6 15 / 16 inches. Sound levels as low as 2.0 sones. Air volume as high as 186 cfm. UL/cUL Listed. • • • • Aluminum Backdraft Damper - Prevents unwanted backdrafts.
12 EXTERNAL JUMPER LOAD LOAD 115 VOL T AC 60 CYCLE (NEUTRAL) (HOT) BLACK BLUE (500 Watt Max) LIGHT (7.5 Amps Max) FAN MOTOR RED WHITE FULL VOL T AGE 120 VAC N H BLACK SPEED CONTROL WHITE VARIABLE VOL T AGE FAN AUX DEVICE SWITCHED FULL VOL T AGE Dotted line indicates for use with 10W switch only .
H 1 BLK SWITCH BOX SWITCH 115 V MOTOR 277 V SUPPL Y 277V TO 115V TRANS. 750 VA H 2 H 3 RED X 1 X 2 RED BLK BLK Grille Motion Detectors are available on models up through size SP-A390 and SP-B200. • Rated for 115v • UL Listed Model MDW For use on fan or lights.
14 E B C A D D A G C B E F B E C A D E B C A Model WL Wall Louvered Discharge • Anodized aluminum grille • Built in damper • Not recommended for exterior applications exposed to severe weather conditions. An external wall louver is recommended for such applications.
15 Model RCC-7 Curb Cap • Weathertight aluminum construction • Integral birdscreen • Built in curb cap • Requires roof curb Model RJ Pitched Roof Cap • Steel construction with black enamel f.
PREMIUM CEILING FAN A SP Dimensional Data Performance Data Performance certified is for Model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed (RPM) shown is nominal.
DELUXE CEILING FAN B SP STANDARD CEILING FAN C SP 17 HVI CFM / Static Pressure in inches of WG Model RPM AMPS Watts Sones 0.000 0.100 0.125 0.250 0.375 0.500 0.625 0.750 1.000 CFM 67 53 51 40 29 SP-B50 625 0.50 38 1.4 Sones 1.7 1.9 1.9 2.6 3.5 CFM 77 70 68 57 49 39 SP-B70 675 0.
18 PREMIUM INLINE FAN A CSP Dimensional Data Performance Data Performance certified is for Model CSP inline for installation type D: Ducted inlet, Ducted outlet. Performance ratings include the effects of a backdraft damper. Speed (RPM) shown is nominal.
19 DELUXE INLINE FAN B CSP Performance certified is for Model CSP inline for installation type D: Ducted inlet, Ducted outlet. Performance ratings include the effects of a backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test.
Greenheck Fan Corporation warrants its SP/CSP products to be free of any defect in material or workmanship for a period of three (3) years from the date of purchase. In the event of such a defect during the warranty period, Greenheck Fan Corporation agrees, at its option, to either repair or replace the defective product free of charge.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Greenheck CSP c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Greenheck CSP - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Greenheck CSP, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Greenheck CSP va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Greenheck CSP, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Greenheck CSP.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Greenheck CSP. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Greenheck CSP ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.