Manuel d'utilisation / d'entretien du produit TRITON 3D150 du fabricant Graco
Aller à la page of 28
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 Copyright 2006, Graco Inc. is r egistered to I. S. EN ISO 9001 311688D Instr uctions/P ar ts List Tr i t o n ® 3D150 Diaphra gm Pump Used to pump waterborne and sol vent-based paints and catalysts. P ar t No.
2 311688D Contents W arning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 General Information . . . . . . . . . . . . . . . . . . . . . . 5 Tightening Thre aded F asteners Bef ore First Use 5 Mounting t he Pump .
Warnings 311688D 3 Wa r n i n g s The f ollowing w ar nings are f or the setup , use, g rounding, maintenance , and repair of this equipment. Th e exclama- tion point symbol ale r t s you to a gener al warning and the hazard symbol r efer s to procedure-specifi c r isk.
Warnings 4 311688D T O XIC FLUID HAZARD Hazardous fluid or t oxic fumes can cause serious injur y or death if splashed in the e y es or on the skin, inhaled, or s wallow ed. • Know the sp ecific hazards of the fl uid you are using. • Store hazardous fluid in an ap prov ed container .
Installation 311688D 5 Installation General Inf ormation •F IG . 2 is only a guide f or installing system compo- nents and acce ssori es. It is not an actual system design. Contact y our Gr aco distribut or f or assis- tance in designi ng a system to suit y our particular needs .
Installation 6 311688D Mounting the Pump • F or ease of oper ation and service, mount the pump so the air inlet, flu id inlet, and fluid outlet po r ts are easily accessible. • Mount the pump in a well- v entilated area with suffi- cient clearance on all sides f or oper ator access and ser vicing.
Installation 311688D 7 Air Line 1. Install the air line accessories as sho wn in F IG . 2. Be sure the air line supplying the accessories is grounde d. a. The fluid pressur e can be controlled with either an air regu lator (F) t o control th e air into th e pump , or with a fluid regu lator (H) to control th e fluid out of the pum p .
Installation 8 311688D F IG . 2. T ypical Inst allation R B C D E F K A L G S M W Key: A TRIT ON 3D150 Pump B Bleed-type master air valv e (required for pump) C Air supply line D Air line filter E Air.
Installation 311688D 9 Gr ounding Ground all of this equipment: • Pump: use a ground wire and clamp . See F IG . 3. Loosen the g rounding scre w (X). Insert one end of a 12 ga (1.5 mm 2 ) minimum gr ound wire (Y) under the clamp and tig hten the scre w securely .
Operation 10 311688D Operation Pressure Relief Pr ocedure 1. Shut off the air to th e pump. 2. Open the dispensing v alv e, if used. 3. Open the fluid dr ain v alve to re liev e all fluid pres- sure, ha ving a container r eady to catch the drainage . Flushing the Pump Bef ore First Use The pump wa s tested in oil.
Maintenance 311688D 11 Maintenance Lubrication Flushing and Storage Flush the pump of ten enough to pre v ent the fluid y ou are pumping fr om curing, dr ying, or freezing in the pump and damaging it . Fo llow the Pressure Relief Procedure on page 10 bef ore storing it f or an y length of time .
Troubleshooti ng 12 311688D T r oubleshooting Relie ve t he pressure (page 10) befo re checking o r servicing the equipment. Chec k all possible prob lems and causes bef ore disassemb ling the pump . Prob lem Cause Solution Pump cycles at stall or f ails to hold pressure a t stall.
Repair 311688D 13 Repair Prepare the Pump f or Repair 1. Flush the pump if possible , page 11. 2. Relie v e the pressure, pag e 10. 3. Disconnect the ai r and fluid hoses .
Repair 14 311688D Replace the Diaphragms Disassembl y 1. Prepare the pump fo r repair of the cylinder-side dia- phragm. a. Remov e the 6 scre ws (39) and fluid co ver (3 7) from the housing side of t he pump . b . Press on the e xposed diap hragm (9) to fully e xtend the cylinder-sid e diaphragm.
Repair 311688D 15 F IG . 4 Replace the Dia phragms TI" T orque to 1 6 N•m (12 ft-lb). 1 29* †‡ ◆ 1 37 54 7 29* †‡ ◆ 29* †‡ ◆ 38 37 29* †‡ ◆ 39 Cylinder Side .
Repair 16 311688D Repair the Air V alve Disassembl y 1. Prepare the pump fo r repair , page 13 . 2. Remov e the air valv e sheet metal co v er (36) and f elt dampener (34) . 3. Unscrew the cylin der screws (21). 4. Remov e the v alv e cov er (20) with the f lat gasket (19†).
Repair 311688D 17 F IG . 5. Repair the Air V alve ti2130B 12 Lubricate. T orque to 3.1 N•m (28 in-lb) Align arrow on housing with point on air valve plate .
Repair 18 311688D Repair the Shaft and Bearings Disassembl y 1. Remov e the diaphragms. See page 13. 2. Disassemb le the air v alve . See page 16. 3. Remove the housing (54).
Repair 311688D 19 F IG . 6. Repair the Shaft Lubricate. T orque to 1 2 ft-lb (16 N•m) Align arrow on housing with point on air valv e plate. T orque to 2 8 in-lb (3.
Repair 20 311688D Replace the Ball Chec k V alves Disassembl y 1. Remo ve fluid cov ers (see page 13) . Do not remov e housing (5 4). 2. Remov e the inlet and outlet ball checks (2 6-32). Note that the orientation of the inlet check par ts is diff erent than the outlet check pa r ts.
Repair 311688D 21 F IG . 7. Replace the Ball Check V alves ti2128B T orque to 12 ft-lb (16 N •m) Align 1 2 1 2 Inlet Ball Checks Outlet Ball Checks 29 ‡ ‡32 ‡26 ‡28 ‡29 1 32 ‡ 26 ‡ 31 .
Parts 22 311688D Pa r t s P art No. 253704, Series B P art No. 253705, Series B 1 ★ 32 ‡ 26 ‡ 31 ‡ 5 *9 23 33 22 12 10 15 † 44 34 † ◆ 19 † 16 † ◆ 18 † ◆ 17 20 *9 ◆❖ 2 4 ‡.
Parts 311688D 23 P art No. 253704 BSPP , Series B P art No. 253705 NPT , Series B ★ Included in Diaphra gm Housing Repair Kit. Order Kit 261665 f or 253704 pum ps and 261666 f or 253705 pumps . ◆ Included in Shaft Repair Kit 233841. ❖ Included in Bearing Repair Kit .
Technical Data 24 311688D T ec hnical Data Sound Pressure Le vels in dB(A) at 50 cpm (measured at 1 me ter from unit) Category Data Maximum flu id working pressure 300 psi (2.
Performance Chart 311688D 25 P erformance Chart T riton perf ormance test, 40, 70, 100 psi (.27, . 48, .69 MP a; 2.7, 4.8, 6. 9 bar) Cycles per minute Outlet Flow in gallons per minute Outlet Pressure in PSI Air Flow in SCFM 40 psi 70 psi 100 psi 40 psi (.
Dimensions 26 311688D Dimensions 234 mm 184 mm (7.2 in.) 104 mm (4.1 in.) (9.2 in.) Fluid Inlet; 253705 3/4 npt 253704 M26x1.5 Fluid Outlet; 253705 3/8 npt 253704 3/8 BSPP 9 mm (0.
Dimensions 311688D 27.
All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. This manual contains English. MM 311688 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Graco TRITON 3D150 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Graco TRITON 3D150 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Graco TRITON 3D150, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Graco TRITON 3D150 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Graco TRITON 3D150, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Graco TRITON 3D150.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Graco TRITON 3D150. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Graco TRITON 3D150 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.